Composition
1. Retractable Probe Tip
2. “Ready” Indicator LED
3. LCD Display
4. Battery Compartment
5. Neck Strap Attachment
6. Adaptor Inlet
7. ON/OFF Switch
8. Ergonomic Grip
9. Probe Protective Cap
f. Do not drop, knock, or shake the tester. Rough handling can break internal circuit boards and
fine mechanics.
g. Do not use harsh chemicals, cleaning solvents, or strong detergents to clean the tester.
h. Do not paint the tester. Paint can clog the moving parts and prevent proper operation.
If the tester is not working properly, kindly contact our customer service at
SmartPro Instrument co.,ltd
249/40, Moo 9, J.S.P. Building
Bangbon 1 Rd., Bangbon
Bangkok 10150 Thailand
+66 (0) 2 899 2956-7
Attn: Customer Service Executive
If batteries are used (3 x AAA batteries), take note of the positive (+) and negative (-) directions of
the batteries when inserting the batteries into the tester (Fig. 1.2). The use of alkaline batteries is
preferred, as it should generally give approximately two and a half hours of continuous operation,
while the use of ordinary batteries will give a shorter working life.
23
21
18
While in this preparation mode, a “SmartPro” will blink continuously on the LCD. The “SmarPro”
will stop blinking when it is show “READY” on the LCD and now ready to be used (Fig. 1.5). The
tester will shut down automatically after 2 minutes of inactivity.
16
Fig. 1.5
The recommended testing temperature is 18oC - 27oC or 65oF - 80oF Please allow the gemstone or
jewelry piece to adjust to room temperature prior to testing. Exposure and/or operation of the tester
outside the room temperature would affect the result and performance of tester.
The probe tip must be placed at the right angle or perpendicular to the facet of gemstone for an
accurate reading.
Tests should be conducted on the table of the gemstone. In the event of any doubt, kindly test on
the girdle of the gemstones instead.
To achieve optimum accuracy for tests involving very small, it is important to allow the gemstone
to cool down before subsequent tests.
Prepare clean tissue / jewelry cloth. Carefully retrieve the gemstone with tweezers and place the
gemstone face down the table (Fig.1.8).
Fig. 1.6
1. GETTING STARTED
Powering up
Turning on
19
This tester can be power by either the use of an AC adaptor (optional item sold separately) or
through the use of batteries. If AC adaptor is used, connect one end of the AC adaptor to the
tester (Fig. 1.1) and the other end directly into an electrical outlet. Please ensure that only the
adapter supplied by SmartPro is used.
Remove the protective cover from the probe tip (Fig. 1.3).
10
a. Keep the tester dry. Precipitation and all types of liquids or moisture can contain minerals that
will corrode electronic circuits. If your tester does get wet, remove the batteries, and allow the
tester to dry completely before replacing it.
b. Do not use, store or expose the tester in dusty and dirty areas. It’s moving part and electronic
components can be damage.
c. Do not use, store or expose the tester in hot areas. High temperatures can damage or shorten
the life of the tester, damage batteries, and warp or melt certain plastics.
d. Do not use, store or expose the tester in cold areas. When the tester returns to its normal tem-
perature, moisture can form inside the device and damage electronic circuit boards.
e. Do not attempt to open the tester other than as instructed in user manual book.
III. IMPORTANT NOTICE
Fig. 1.1
Fig. 1.3
17
Press the [ON/OFF] button located at the back of the tester (Fig. 1.4) and wait for about 20 sec-
onds to warm up the instrument.
15
Fig. 1.4
Cleaning the probe tip
Please note that if the tester is being used for the first time, or if the tester has not been used for
a week, it is advisable to clean the probe tip using an oxidation removal sheet to attain consistent
and accurate reading.
b. Hold the probe pen with pen tip forming the right angle (90 degree) with an oxidation removal.
Gently move in a circular motion without retracting the tip (Fig. 1.6).
a. Ensure the unit is switched off.
c. Repeat the same motion several times. The cleaning process is completed and tester is now
ready for use.
The gemstone should be clean and dry before testing. However, elaborate cleaning procedures
are not normally necessary (Fig. 1.7).
Recommended testing conditions
Fig. 1.7