6. DIP SWITCHES
DIP ON OFF
1Tamper disabled Tamper active
2Not used Not used
3OUT active to GND OUT active open
4CS input active at +12V CS input active at GND
5SI input active at +12V SI input active at GND
6ALL input active at +12V ALL input active at GND
7Power ON Power OFF
8Smoke enabled Smoke disabled
7. DIAGNOSTIC LEDs
BLUE Lampeggia durante il periodo di preallarme.
GREEN A brief flash indicates the triggering of the
smoke capsule. Useful during installation.
RED Reports the smoke capsule is empty.
8. OUTPUTS
The 24H output is a clean contact
that is always closed when the bo
is closed or the DIP1 is ON..
The OC output switch to GND for
90 seconds after the smoke
capsule run. Useful to drive the
internal siren or an e ternal alarm
device.
The OUT output become active
when the smoke capsule is empty.
It can be active open or to GND,
according to DIP 3.
9. WALK TEST
Press the Walk Test button to activate the diagnostic
function for 10 minutes to turn on the blue LED every time
the passive infrared detects movement. This allows to
position the device to obtain the ma imum coverage of the
built-in infrared. When the Walk Test mode is active, the
ne t press of the button will stop it.
10. VALIDATION BOARD
The validation card is plugged to the
mother board and must be replaced
together with the smoke capsule
after each use. A flash of the red
LED indicates that the capsule is
not e hausted.
11. COMMISSIONING
IMPORTANT: Keep OFF the DIP 7 and 8 during wiring.
Set DIP 7 to ON to power the board and carry out the
tests, only at the end of installation job put ON the DIP 8
to enable the smoke capsule.
The simulation tests of the smoke delivery keeping the
DIP 8 in the OFF position, can only be performed within
4 hours from the power supply of the board, after
which the validation board will be irreparably consumed.
It is therefore recommended to switch OFF and ON
again the device with DIP 7 as the first thing to do in
case of maintenance to a device installed for a long
time.
Before the final commissioning, it is advisable to carry out
both the Walk Test and some real simulations, with the
DIP8 in the OFF position, where the green LED will emit a
short flash that simulates the ignition of the fumigation
capsule.
At the end of the installation, remove
the adhesive that protects smoke exit
hole of the smoke cartridge.
Installation manual NUBI F1 www.smarteksrl.it Pag. 2 of 3
12. WORKING LOGIC
NUBI can be driven only with CS input (immediate discharge), or using the SI and ALL inputs in conjunction by the
integrated infrared sensor. The operating logic is shown in the following diagram: