Skope BB380r-2 Manual del propietario

380r-2 Door
580r-3 Door
780r-4 Door
SKOPE Backbar Remote Chillers
Horizontal Display and Storage
nstallation and Operating nstructions
MAN0706 Rev. 1.0 Dec. 2003 edition
Model: BB380r-2SW


BB380r-2, BB580r-3, BB780r-4
SKOPEBackbarRemote Chillers
Designed and Manufactured by
New Zealand
SKOPE INDUSTRIES LIMITED
PO Box 1091,Christchurch
NewZealand
Freephone: 0800 947 5673
Fax: (03) 983 3896
E-mail: enquiry@skope.co.nz
Website: www.skope.co.nz
Australia
SKOPE AUSTRALIA PTY LTD
A.C.N. 000 384 270
PO Box 7543,Baulkham Hills B.C.
NSW 2153, Australia
Freephone: 1800 121 535
Fax: 1800 121533
E-mail: enquiry@skope.com.au
Website: www.skope.com.au
Middle East
SKOPE INDUSTRIES MIDDLE EAST
PO Box 37663, Dubai
UnitedArab Emirates
E-mail: skopeme@emirates.net.ae
CONTACT ADDRESSES
i

BB380r-2, BB580r-3, BB780r-4
SKOPE Backbar Remote Chillers
BB380r-2, BB580r-3, BB780r-4
SKOPE Backbar RemoteChiller
Installation and OperatingInstructions
MAN0706
Rev. 1.0 Dec. 2003 edition.
Published by
SKOPE IndustriesLimited,
Christchurch, New Zealand.
Copyright© 2003
SKOPE IndustriesLimited.
All rights reserved.
SKOPE and CYCLONE are
registered trademarks of
SKOPE IndustriesLimited.
SKOPE IndustriesLimitedreserve the
right toalter specifications without
notice.
ii

BB380r-2, BB580r-3, BB780r-4
SKOPEBackbarRemote Chillers
1SPEC F CAT ONS
1.1Cabinet and Refrigeration Unit. . . . . . . . . . . . . . . . . . . . . . .6
2NSTALLAT ON
2.1Positioning of Machine. . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.2Refrigeration System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3OPERAT ON
3.1Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
3.2Operation of Machine. . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3.3Loading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
3.4Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3.5Servicing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4ELECTRONC CONTROLLER
4.1Controller Display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4.2Controller Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4.3Programming Controller . . . . . . . . . . . . . . . . . . . . . . . . . . .16
4.4Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
4.5Display Alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
TABLE OF CONTENTS
iii

6BB380r-2, BB580r-3, BB780r-4
SKOPE Backbar Remote Chillers
1.1Cabinet and Refrigeration Unit
* Height excludescastors orlegs
Cabinet Construction
Finish: Stainless steel orpowdercoatedgalvanised steel
Insulation: 50mmthick, polyurethanefoam
Cyclo-isoPentane blowingagent: C5H10/C5H12
Dimensions
Models: BB380r-2 BB580r-3 BB780r-4
Doors: 2 Door 3Door 4 Door
Height: 920mm* 920mm* 920mm*
Width: 1355mm 1915mm 2475mm
Depth (Solid Back): 590 - 600mm(with bench top)
Depth (Pass-Thru): 655 - 670mm(with bench top)
Floor area: 0.81m21.14m21.48m2
Internal volume: 380 litres 580 litres 780 litres
Electrical
Power supply: 220-240V a.c. 50Hz, single phasepowersupply
Run Amps: See rating label insidecabinet
Interior light: 1 x 36 Watt 1x 58 Watt 1 x 58 Watt
Refrigeration Unit
Product temp: +1°Cto +4°C
Rated ambient: 32°C at 65% RH
Evap. capacity 480 Watts 615 Watts 850 Watts
Evaporator: CLS9902R
TX valve - R134a VAL7923
TX valve - R404A VAL9641
TX valve - R22 VAL9643
Orifice: ‘0X’ REF9761 ‘00’ REF7596 ‘00’ REF7596
Refrigeration tail Ø: Liquid line: 1/4” Suction line: 3/8”
Drain Ø: 19mmO.D.
SPECF CAT ONS
1

7
BB380r-2, BB580r-3, BB780r-4
SKOPEBackbarRemote Chillers
2.1Positioning of Machine
Castors / Legs
If your SKOPE Backbar chiller has been supplied with either the
optional adjustable height castors or adjustable legs (packed with
the cabinet), they should be fitted to the base of the cabinet before
final positioning of the chiller.
Siting chiller
When installing the chiller it is important to consider the location and
physical environment where the chiller is to be positioned. When
siting the chiller, avoid direct sunlight and warm draughts etc.
Maximumrecommended operating ambient temperature is 32°Cat
65% RH, and for tropical machines is 40°C at 75%RH.
Adequate allowance should be made for door opening. The chiller
must be positioned on alevel surface for the doors to shut and seal
correctly, and to prevent the condensate tray from overflowing.
Shelves
Remove all packaging material from the shelves. Clip the shelf
support brackets into the shelf support strips, at the desired heights,
and fit the shelves.
Shelves may be positioned at different heights to suit various
products. Always ensure that the shelf clips are securely engaged in
each of the shelf support strips. Shelf support strips are marked ‘+’
for easy location of shelf clips.
NSTALLAT ON
2

8BB380r-2, BB580r-3, BB780r-4
SKOPE Backbar Remote Chillers
Mains flex
The mains flex exits below the refrigeration unit front cover. Initial
retrieval of the mains flex is from inside the refrigeration unit
compartment, behind the unit front cover. To retrieve the mains flex:
1.Open the unit front cover: firstly undo the fixing screw at bottom
of cover, then lift the cover up from the bottomand swing open.
2.Pull the mains flex fully out from the unit compartment, and
remove the rubber band.
3.Push the unit end of flex into the grey plastic clip beside the
front cover bottom hinge, and close the plastic clip over the
flex, ensuring it is held firmly in place.
4.The mains flex can now be run under the cabinet, and plugged
into a power socket
5.Close the unit front cover: by lifting the cover up from the
bottom and pushing firmly closed. Remember to refit the
bottom fixing screw.
NSTALLAT ON
2
Figure1: Mains Flex
Flex Clip
Unit Front Cover
MainsFlex
Bottom Hinge
Cabinet Base

9
BB380r-2, BB580r-3, BB780r-4
SKOPEBackbarRemote Chillers
2.2Refrigeration System
Drain
A500mm long, 19mm O.D. PVC drain hose is supplied. All drainage
is to conform to local regulations, covering removal of condensate to
waste water. Ensure drain is trapped with adequate fall. Venting the
drain may be required for a restrictive run.
Refrigeration lines
A 1/4” liquid line, and 3/8” suction line are provided to attach pipe
lines to. The suction lines must be insulated.
NOTE:The electronic controller supplied with the cabinet can switch
a solenoid. No solenoid is supplied with the remote unit.
Refrigeration Practice
Installation must be performed by arefrigeration tradesperson, to an
appropriate standard complying with all local regulations.
Performance depends on the overall installation (including
condensing unit). Cabinet suitability must always be quantified for
the application. The final responsibility for condensing unit
performance and component selection rest with the installer. The
installer must check matters such as:
•Heat load
•Refrigeration load
•Variable operating conditions (usage, ambient, humidity)
•Refrigeration pipe sizing
•Refrigeration pipe length (distance, elevation, pressure drop)
•Location and ventilation (cabinet and condensing unit)
•Drainage
NSTALLAT ON
2

10 BB380r-2, BB580r-3, BB780r-4
SKOPE Backbar Remote Chillers
•Power supply
•Unit is fully evacuated prior to charging
•All cabinet penetrations are sealed
Electrical
The cabinet is supplied with a 3-core 10 Amp mains flex and plug.
The cabinet lighting and centre pillar heater elements are protected
by a 3 Amp fuse, located in the unit junction box.
If a solenoid is fitted and controlled by the electronic controller, the
solenoid will need connected to the connector block inside the unit
junction box.
NSTALLAT ON
2
Figure 2:Refrigeration Pipework
Unit Pipework Cover Refrigeration Unit Compartment
Drain Tube
Suction Line
Liquid Line
Rear of Cabinet
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Manuales populares de Almacenamiento de otras marcas

Spectra Logic
Spectra Logic T-Series Spectra T50e Manual de usuario

Panasonic
Panasonic LKM-F931-1 Manual de usuario

Tabernus
Tabernus Enterprise Erase E2400 Manual de usuario

Rocstor
Rocstor COMMANDER 3F series Manual de usuario

HP
HP P9000 Manual de usuario

Western Digital
Western Digital Ultrastar Data60 Manual de usuario