SITGroup PROFLAME 2 Basic Manual de usuario

ADVANCED REMOTE CONTROL SYSTEMS
PROFLAME 2 Basic, Standard, Complete
9.955.116 02 Subject to change without notice
www.sitgroup.it

2
The Proflame 2 is a modular remote control system that directs the functions of a
hearth appliance. It was designed in Basic, Standard or Complete configurations for
ATMO or FAN assisted appliances and now available in Basic ATMO, Complete ATMO
or Complete FAN/ATMO versions.
•
The Basic Proflame 2 is an automatic gas ignition control system that includes a
selectable intermittent or standing pilot setting. Features include: twin safety system
with true flame rectification current detection for enhanced safety and reliability,
On/Off, Manual Hi/Low operation from a wall switch, a low power consumption
design provides a choice for AC power or AC power with battery back up.
The 880 Proflame gas valve provides basic ON/OFF operation of gas flow to the
pilot and main burner of the heating appliance.
The 886 Proflame gas valve has the same functions as the 880 gas valve with the
added feature of manual flame adjustment by a Hi/Low knob.
The Proflame valves have been designed for use with either LPG or Natural Gas
and can be converted by use of OEM supplied conversion kits.
The 880 Proflame valves can also be upgraded to 886 configurations by installing
OEM supplied conversion kits.
•
The Standard Proflame 2 is a remote control system that directs multiple functions
of modern hearth appliances. The Standard Proflame 2 adds to the Basic Proflame
2 system the control of On/Off and flame height adjustment operation of the main
burner, allows to operate a Split Flow dual burner control.
The Standard Proflame 2 system is specifically developed to be used together with the
Proflame 885 valve and provides for battery back up in the event of line power loss.
•
The Complete Proflame 2 is a remote controls system that directs multiple functions
of modern hearth appliances. The Complete Proflame 2 adds to the Standard the
comfort fan speed control through off to 6 levels, a remotely actuated 120/60Hz
power outlet and optional combustion fan control. Comfort control is advanced
by the Smart thermostat feature which automatically modulates the flame height
optimizing the temperature management and the room ambience.
The Complete Proflame 2 system is specifically developed to be used together with the
Proflame 885 valve and provides for battery back up in the event of line power loss.
Note: if an optional combustion fan is used, the appliance can not be operational
in battery back up mode.
• For operation with a less sensitive response time to movement of the flame with
relationship to the sensing electrode, the IFC unit can be ordered with extended
"FFRT" option (CSA certified only). With this option a "Flame Failure Response
Time" (5s) with extended "Recycle Time" (30s) are adopted. In case of flame
failure detection, the system will not react immediately, but will wait for FFRT
expiration before entering lockout (in ATMO configurations) or re-igniting (in
FAN configurations).

3
mitte
PROFLAM
F
885 PROFLAME
Combination Gas Control
SPLIT FLOW
OFLAME
MC
880 PROFLAME
Combination Gas Control
IFC
885 PROFLAME
Combination Gas Control
BASIC PROFLAME 2
STANDARD PROFLAME 2
er
PROFLAME
Transmitter
IFC
ME
FLAM
885 PROFLAME
Combination Gas Control
SPLIT FLOW
COMPLETE PROFLAME 2
FAN LIGHT
LOCAL USER INTERFACE
PROFLAM
F
IFC
PROFLAM
F
OPTIONAL EXTERNAL
RF RECEIVER
OPTIONAL PROFLAME
TRANSMITTER
SPECIFIC IFC CODE
AVAILABLE ON REQUEST

4
MAIN CHARACTERISTICS
Feature Transmitter
PROFLAME 2
Icon
TMFSLA(1) TMFSL(2) TMFL(3)
Room Temperature Display • • •
Child Lock • • •
Low Battery indicator • • •
On/Off Thermostat • • •
Flame On/Off & Modulation (6 Levels) • • •
Smart Thermostat • • •
Fan Speed Control (6 Levels) • • •
On/Off Auxiliary Outlet (120V) ••
Split flow (dual flame) •••
IPI/CPI (4) ••• •
Light modulation (6 levels) ••• •
Referring to the remote control:
(1)
TMFSLA indicates enabled function: Thermostat, Modulator flame, Fan, Split flow, Lights modulation, Auxiliary output
(2)
TMFSL
indicates enabled function: Thermostat, Modulator flame, Fan, Split flow, Lights modulation
(3)
TMFL
indicates enabled function: Thermostat, Modulator flame, Fan, Lights modulation
(4) CPI
indicates Continous Pilot Ignition;
IPI
indicates Intermittent Pilot Ignition
(•)
Indicates included Features
The table below shows the configurations currently available.

5
The BASIC System consists of four main elements:
1. Proflame 2 Integrated Fireplace Control (IFC) Basic model
2. Proflame 880, or 886 families of gas valves
3. Pilot assembly
4. Wiring harness to connect the IFC to the gas valve, pilot burner and control switches.
The STANDARD System consists of seven main elements:
1. Proflame 2 Integrated Fireplace Control (IFC) Standard model
2. Proflame Gas Valve 885 family (also the 880, 886 families are compatible)
3. Wiring harness to connect the IFC to the gas valve stepper motor, control switches and to
the Split Flow Control
4. Proflame 2 Transmitter and receiver (optionals)
5. Pilot assembly
6. Split Flow valve (optional)
7. Local user interface.
The COMPLETE System consists of seven elements (ATMO configuration), eight elements (FAN
configuration):
1. Proflame 2 Integrated Fireplace Control (IFC) Complete model
2. Proflame Gas Valve 885 family (also the 880, 886 families are compatible)
3. Wiring harness to connect the IFC to the control switches, and -depending on the FAN/
ATMO configuration- to the APS
4. Proflame 2 Transmitter
5. Pilot assembly
6. Split Flow valve (optional)
7. Comfort fan, dimmable lights, auxiliary device (optional)
8. In Fan configuration, the combustion Fan with Air Pressure Switch (APS) safety device.
TECHNICAL DATA
REMOTE CONTROL TRANSMITTER
Supply voltage 4.5 V (three AAA LR03 1.5 V batteries)
Ambient operating temperature 0 to 50 °C (32 to 122 °F)
Radio frequency 315 MHz (FCC version)
433.92 MHz available (CE version)
AC supply voltage and frequency 120 V ~ 60 Hz - 2.5 A max
BB supply voltage 6 Vdc - 200 mA max (four 1.5V AA batteries)
Ambient operating temperature -10 to 80 °C (14 to 176 °F)
Radio frequency 315 MHz
Aux switched output 120 V / 60 Hz / 5 A
Fan speed output 120 V / 60 Hz / 2
Light dimming output 120 V / 60 Hz / 0.5 A
Spark voltage >15 kV
Spark energy >0,7 mJ
Spark frequency 1Hz
Tested gas types the system has been tested both for NG, and LPG gas types/mixtures
Pilot ignition source Intermittent/Continuous
INTEGRATED FIREPLACE CONTROL (IFC) MODULE
SYSTEM COMPONENTS

6
Fig. 2: Proflame 2 & Proflame Wall Mount Transmitter LCD display
Low battery alarm
Child safety lock-out
Room
Temperature
Dimmer ON
Set Point
Temperature/Level/State
Flame ON
Thermostat OFF/
ON/SMART
Comfort fan
Transmission
Split Flow
Aux ON
CPI mode
TRANSMITTER (Remote Control with LCD Display)
The Proflame Transmitter uses a streamline design with a simple button layout and informative
LCD display (Fig. 1). A Mode Key is provided to index between the features and a Thermostat Key
is used to turn on/off or index through Thermostat functions (Fig. 1A & 1B & 2).
Fig. 1A: Proflame 2 Transmitter.
Blue LCD display
UP/DOWN Arrow Key
ON/OFF Key
THERMOSTAT Key
MODE Key
Fig. 1B: Proflame Wall Mount Transmitter.
Blue LCD display
UP/DOWN Arrow Key
ON/OFF Key
THERMOSTAT Key
MODE Key

7
IFC MODULE
Fig. 3: Proflame 2 IFC Board.
The Proflame 2 Integrated Fireplace Control (IFC) board is a device that allows the automatic
ignition and pilot flame supervision, to command the functions of a hearth appliance, see fig.3.
It’s configured to control the ON/OFF main burner operation, giving the choice of both IPI
(intermittent pilot ignition), and CPI (continuous pilot ignition) modes.
The Proflame 2 IFC board controls and connects directly to the pilot assembly and an automatic
valve of the Proflame 880, 886 and 885 families using low electric power.
The IFC Board can be powered by an AC and battery pack for back up (ATMO Systems only).
The Proflame 2 offers the added ability to control the comfort fan speed from OFF through six (6)
speeds, a remotely actuated auxiliary outlet and a dimmable light outlet. The external batteries can
provide DC power to the IFC allowing the batteries to be used only when line power is interrupted
or lost, and if the appliance does not use a combustion fan.
PILOT
1116690
0584922
0584921
0584920 / 0584924

8
INSTALLATION
Proflame Wall Mount Transmitter
The Proflame remote control is supplied with an adapter for wall mounting.
Install the controller 1.5 m above floor level, well away from heat sources, kitchens, doors or
windows.
Metallic structures or radio interferences can reduce the operative distance of the device.
Make sure to attach the adapter in a level plane without any distortion. Proceed as follow:
Wall mounting
1. Detach the adapter from the body of the remote control; see Fig. A.
2. Position the adapter on the wall, mark the points for the fixing holes and drill the wall.
3. Fix the adapter on the wall using the mounting hardware supplied with the remote control.
4. Insert the remote control onto the adapter as shown in Fig. B.
Fig. B: Adapter and remote control.
Fig. A: Detach the adapter from the body.

9
IFC module
The IFC can be placed inside a low temperature area of the appliance.
Mounting into the appliance
1. Connect the wiring harnesses to the IFC.
2. Install the IFC in the appliance using the screws. (Fig. 4)
3. Insert the 4 AA type batteries in the battery holder with the correct polarity.
4. Connect the switches.
5. Put the main switch in the “OFF” position (open) and the IPI/CPI switch on IPI position (open).
6. Connect the wiring harnesses to the loads.
Fig. 4: Proflame 2 IFC Board installation.

10
INSTALLATION
Connecting to the 880/886 Gas Valve and IFC control board in BASIC configuration
The electrical connections must be in accordance to Fig. 5.
0.880.XXX
0.886.XXX
0.190.XXX
0.584.920
0.584.307
0.584.952
Fig. 5: Proflame 2 BASIC IFC & 880/886 PROFLAME wiring diagram.
GROUND
Chassis
connection
0.584.920
or
0.584.924
X5 X4 X3 X2
X1
ON / OFF
IPI / CPI
BATTERY
PACK
Este manual sirve para los siguientes modelos