1 Warnings and Cautions ........................................................ 1
Safety information symbols 1
Cautions 1
2 Nameplates and Placards..................................................... 3
3 Description and Specication.............................................. 4
4 Unpacking ............................................................................. 9
Included Components and Parts 9
Primary Inspection 9
5 Installation ..........................................................................10
Welding FuelPort to Tank 10
Attaching FuelPort to Post 10
Attaching FuelPort to Base 11
Mounting FuelPort Recessed into Wall 11
Mounting Full-Size FuelPort 11
6 Operating Instructions .......................................................12
APPENDIX A PRODUCT WARRANTY .................................................13

Table of Figures
Specications.....................................................................................................5
FuelPort Dimensions .......................................................................................6
Full-Size FuelPort Dimensions......................................................................7
Recessed-Mount FuelPort Dimensions.....................................................8
Weld Brackets.................................................................................................. 10
FuelPort Post ................................................................................................... 10
FuelPort Base................................................................................................... 10

Warnings and Cauons — 1
1 WARNINGS AND CAUTIONS
The following images indicate important safety information:
This General warning symbol points out important
information that, if not followed, could endanger
personal safety and/or property.
This Explosion warning symbol points out poten-
tial explosion hazards.
This Fire warning symbol points out potential fire
hazards.
This Electrical warning symbol points out potential
electrical shock hazards.
•Improper operation of this equipment such as neglecting its
maintenance or being careless can cause possible injury or
death. Permit only responsible and capable persons to install,
operate, and/or maintain this equipment.
•Potentially lethal voltages and amperages are present in these
machines. Ensure all steps are taken to render the machine
safe before attempting to work on the equipment.
•All hardware covered by this manual have dangerous elec-
trical voltages and can cause fatal electrical shock. Avoid
contact with bare wires, terminals, connections, etc., on the
hardware, if applicable. Ensure all appropriate covers, guards,
grounds, and barriers are in place before operating the equip-
ment. If work must be done around an operating unit, stand
on an insulated dry surface to reduce shock hazard.
•Do not handle any kind of electrical device while standing in
water, while barefoot, or while hands or feet are wet. DAN-
GEROUS ELECTRICAL SHOCK MAY RESULT.
•If trained personnel must stand on metal or concrete while
installing, servicing, adjusting, or repairing this equipment,
place insulative mats over a dry wooden platform. Work on
the equipment only while standing on such insulative mats.
•The National Electrical Code (NEC), Article 250 requires the
frame of the equipment to be connected to an approved earth
ground and/or grounding rods. This grounding will help
prevent dangerous electrical shock that might be caused by a
ground fault condition or by static electricity. Never discon-
nect the ground wire.
•Wire gauge sizes of electrical wiring, cables, and cord sets
must be adequate to handle the maximum electrical current
Safety
information
SymbolS
!
!
CautionS

2 — Warnings and Cauons
(ampacity) to which they will be subjected.
•Before installing or servicing this (and related) equipment,
make sure that all power voltage supplies are completely
turned off at their source. Failure to do so will result in haz-
ardous and possibly fatal electrical shock.
•In case of accident caused by electric shock, immediately shut
down the source of electrical power. If this is not possible,
attempt to free the victim from the live conductor. AVOID
DIRECT CONTACT WITH THE VICTIM. Use a noncon-
ducting implement, such as a dry rope or board, to free the
victim from the live conductor. If the victim is unconscious,
apply first aid and seek immediate medical attention.
•Never wear jewelry when working on this equipment. Jewel-
ry can conduct electricity resulting in electric shock or may
get caught in moving components causing injury.
•Keep a fire extinguisher near the hardware at all times. Do
NOT use any carbon tetra-chloride type extinguisher. Its
fumes are toxic, and the liquid can deteriorate wiring insula-
tion. Keep the extinguisher properly charged and be familiar
with its use. If there are any questions pertaining to fire extin-
guishers, please consult the local fire department.
•The illustrations in this manual are examples only and may
differ from your unit.
!


4 — Descripon and Specicaon
3 DESCRIPTION AND SPECIFICATION
The Simplex FuelPort is a compact, economical solution for
simple filling and spill prevention for fuel-storage tanks. The Fu-
elPort includes all valves and fittings necessary for hose connec-
tion from a pumper truck.
The FuelPort is available in two models: The standard Fu-
elPort, which is 32 inches tall and has a 7-gallon containment
capacity, and the Full-Size FuelPort, which is 51.5 inches tall and
has a 20-gallon containment capacity, as well as a storage bin.
The FuelPort can be bolted to the tank, be attached to a base,
or attached via clamps to a 2” or 3” post.
The Full-Size FuelPort can be secured against a wall or floor.
Both models are suitable for use with fuel oil or gasoline.

Descripon and Specicaon — 5
Table 1 Specifications
Delivery Type Pumper truck
Enclosure Weatherproof, lockable box with 7 gallon spill contain-
ment
Inlet Connection Quick disconnect hose coupling with dust plug
Shutoff Manual
Types of Fuel Class I liquids, < 100°F flash point (Gasoline)
Class II liquids, 100°F - 140°F flash point (Diesel fuel)
Inlet Fitting Size 2”, 3” or 4” (3” internals and 3” NPT outlet)
Spill
Containment
FuelPort: 7 gallons
Full-Size FuelPort: 20 gallons
Surface Finish UL-listed powder-coat process
Hand Pump
Capacity
1 GPM
Dimensions
(Approximate)
FuelPort: 24”W x 32”H x 20.5”D
Full-Size FuelPort: 35”W x 51.5”H x 24”D
FuelPort with Flush Wall-mounting Flange: 30”W x
38.5”H x 25”D
Weight
(Approximate)
FuelPort: 129 lbs.
Full-Size FuelPort: 250 lbs.
FuelPort with Flush Wall-mounting Flange: 245 lbs.

6 — Descripon and Specicaon
Figure 1 FuelPort Dimensions
Tabla de contenidos
Otros manuales de Equipos de extinción de incendios de Simplex
Manuales populares de Equipos de extinción de incendios de otras marcas

Tyco Fire Protection Products
Tyco Fire Protection Products AM31 AQUAMIST Nozzle Manual de usuario

Task Force Tips
Task Force Tips Extend-A-Gun RC3 Manual del propietario

Autronica
Autronica AutroSafe BSD-321/EX Manual de usuario

POK
POK Froggy Manual de usuario

Waterous
Waterous AQUIS Series Manual

CTP
CTP NPO ETERNIS GUARANT-7 Manual de lista de piezas