Deployment Suggestions
Deployment Notes
General
1. The system should be deployed indoors in a relatively stable ambient temperature.
2. Any quick changes in temperature will impact on the blackbodies ability to regulate its surface
temperature. This will then have an impact on the accuracy of the system
3. If the system is to be deployed outdoors then protect from the environment by installing inside
a container / tent.
4. Avoid areas that have a number of high temperature objects in the FOV. If any present, use
the shield zones to shield them out.
5. Avoid placing directly at the entrance from the outside. Force the person to walk through a
channel first before screening. This will allow enough time to reduce the impact on their skin
temperature based on the outside conditions.
MODUM Camera
1. The MODUM Camera should be deployed around 2m from the people to be screened.
2. For best performance the MODUM Camera should be roughly head-height of the people to
be screened minimising the angle of incidence to their faces as much as possible.
Black Body
1. The Black Body should be deployed towards to top of the Field of View (FOV) of the MODUM
camera in an area that will not be obstructed.
2. Deploy as close to the range you want to screen at. I.e., if the people are to be screened at
2.5m deploy the blackbody at that range.
3. Avoid areas with high air flow. This may impact on the black bodies ability to maintain it’s
temperature.