Alert
Movement Activation
Use the following guide to set up your monitor to illuminate the person to person symbol on your Pager or SignWave
when triggered. For advanced settings please refer to instructions overleaf.
2. The test button will flash amber /
green on start up, then flash
amber for up to 30 seconds whilst
the movement sensor stabilises.
This is normal.
Sound Activation
It is possible to enable sound monitoring as well as movement detection. Audio trigger delays can be used to reduce false
alarms from transient noise (door slams etc).
Move Key 12 to the right. Connect the power
supply (PS3A-2207-UK) into the unit, looping
the cable around the strain relief. Plug the
power supply into a mains socket.
If mains failure monitoring is required connect
a 9V Alkaline PP3 to the battery clip.
1.
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
UM3A-2212-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11 = Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Move keys 5 & 7
to the right.
1.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
UM3A-2212-EU-PIR-MKX
MOVEMENT MONITOR 11/12/13
USE MAINS POWER SUPPLY
PS3A-2207-UK ONLY
SILENT ALERT SA3000 SYSTEM
WWW.SILENTALERT.IE Silent Alert International, Ireland
TEL +353 (0)1 247 9007
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 mins
11= Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
MOVE KEY DOWN
TO SWITCH ON
Configuration switches
Audio spindle
Test button
PP3 battery clip
Power Supply socket
Passive
infra red
movement
sensor
Turn the spindle on the side of the
monitor half a turn clockwise until the
slot is horizontal.
A good way to test the unit is to
whistle about 2 metres away from it.
More sensitive Less sensitive
2. The test button will light amber
when a sound is detected and
change to green once it has
been accepted.
Switches 7 & 8 alter the
delay period.
short medium long
3.
40 - 70cm
3. Position the unit & adjust the
sensor to cover the area you
wish to monitor. Ensure the unit
is at least 40cm from the floor &
fix to the wall with the screws and
wall plugs provided. Use the
keyhole slots in the back of the
unit to secure.
1 = System Code 1
2= System Code 2
3 = System Code 3
4 = System Code 4
5 = Audio Monitoring
6 = Zone Multiplier (7-12)
7 = Short Audio Delay
8 = Medium Audio Delay
7 & 8 = Long Audio Delay
9 = PIR Delay 5 Mins
10 = PIR Delay 10 Mins
9 & 10 = PIR Delay 15 Mins
11= Zone 6
12 = Zone 5
13 = Zone 4
14 = Zone 3
15 = Zone 2
16 = Zone 1
38mm
TOP
Drill Template
TM
Silent
Alert
Quick start guide UM3A-2212-EU-PIR
Passive Infra Red (PIR) Movement Monitor
Any questions? Call us on +353 (0)1 247 9007