SignitePro CA30000BL Manual de usuario

CA-529- 2019-11-15
DO NOT REMOVE THESE TAGS
When used without adequate combustion and ventilation air,
heater may give o excessive CARBON MONOXIDE, an
odorless, poisonous gas.
DO NOT INSTALL UNTIL ALL NECESSARY PROVISIONS ARE MADE
FOR COMBUSTION AND VENTILATION AIR. CONSULT THE WRITTEN
INSTRUCTIONS PROVIDED WITH THE HEATER FOR INFORMATION
CONCERNING COMBUSTION AND VENTILATION AIR. IN THE ABSENCE
OF INSTRUCTIONS REFER TO THE NATIONAL FUEL GAS CODE, ANSI
Z223.1/NFPA 54, AIR FOR COMBUSTION AND VENTILATION, OR
APPLICABLE LOCAL CODES.
This heater is equipped with a PILOT LIGHT SAFETY SYSTEM
designed to turn o the heater if not enough fresh air is available.
DO NOT TAMPER WITH PILOT LIGHT SAFETY SYSTEM!
If heater shuts o, do not relight until you provide fresh air.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH.
If heater keeps shutting o, have it serviced. Keep burner and control
compartment clean.
Early signs of carbon monoxide poisoning resemble the u with headaches,
dizziness and/or nausea. If you have these signs, heater may not be working
properly. Get fresh air at once! Have heater serviced.
Some people - pregnant women, persons with heart or lung disease, anemia,
those under the inuence of alcohol, those at high altitudes - are more aected by
carbon monoxide poisoning than others.
WARNING
1

CA-529-
2019-11-15
Removal of this marking will void the compliance of this heater with
ANSI Z21.11.2.
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a re
or explosion may result causing property damage, personal injury
or loss of life.
A. This appliance has a pilot which must be lighted using the electronic
ignitor. When lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas.
Be sure to smell next to the oor because some gas is heavier than air
and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Follow
the gas supplier’s instructions
• If you cannot reach your gas supplier, call the re department.
C. Use only your hand to push in or turn the gas control knob. Never
use tools. If the knob will not push in or turn by hand, don’t try to repair
it, call a qualied service technician. Forced or attempted repair may
result in re or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.
WARNING: Improper installation, adjustment, alteration, service, or
maintenance can cause property damage, personal injury, or loss of life.
Refer to the owner’s information manual provided with this appliance.
Installation and service must be performed by a qualied installer,
service agency, or gas supplier
1

CA-529- 2019-11-15
1. STOP! Read the safety information on the previous tag.
2. Turn o all electric power to the appliance.
3. Turn control knob clockwise to the “OFF” position.
LIGHTING INSTRUCTIONS
Thermostat Models
Ignitor
Control Knob
OFF
PILOT
1
2
3
4
5
Fig. 1 - Control Knob & Ignition
4. Wait (5) minutes to clear out any gas. Then smell for
gas, including near the oor. If you smell gas, STOP!
Follow “B” in the safety information on the previous tag.
If you don’t smell gas, go to the next step.
5. Turn knob counterclockwise to the “PILOT”
position. Depress control knob.
6. With control knob depressed, push down on the ignitor
button until the pilot lights. The pilot is visible centered
below the plaques, behind the front grille.
• Do not attempt to light the pilot by hand
7. Keep control knob depressed for (30) seconds
after pilot lights. Release control knob.
• If the control knob does not pop up when released, stop
and immediately call a qualied service technician or
gas supplier.
• If pilot goes out repeat steps 3 through 7. Wait (1) minute
before attempting to light pilot again. If after several tries
the pilot still goes out, turn the gas control knob
clockwise to the “OFF” position and call a
qualied service technician.
8. Turn on all electric power to the appliance.
9. Turn control knob counterclockwise to the
desired setting
TO TURN OFF GAS TO APPLIANCE
1. Turn o all electric power to the appliance if service is to be performed
2. Push in gas control knob slightly and turn clockwise to “OFF” position.
DO NOT FORCE.
2
Fig. 3 - Infrared model
Fig. 2 - Blue Flame model

CA-529-
2019-11-15 2
Fig. 1 - Correct Pilot Flame Pattern
Infrared model
Fig. 2 - Incorrect Pilot Flame Pattern
Infrared model
Fig. 3 - Correct Pilot Flame Pattern
Blue Flame model
Fig. 4 - Incorrect Pilot Flame Pattern
Blue Flame model
Fig. 5 - Correct/Normal Flame Pattern
with short ames with control knob
set to high ame
Infrared Model
Fig. 6 - Incorrect/Normal Flame Pattern
with short ames with control knob
set to high ame
Infrared Model
The upper third of ame
may be bright yellow when
operated on propane.
1/2 Combustion
Chamber
Height
Fig. 7 - Correct/Normal Flame Pattern
with short ames with control knob
set to high ame
Blue Flame Model
Fig. 8 - Incorrect/Normal Flame Pattern
with short ames with control knob
set to high ame
Blue Flame Model
1/2 Combustion
Chamber
Height
Away from the Other Side of the Heater
*A Second Side Wall Must be at Least 18 in.
A second side wall must be
min. 18 in. from the side of
the heater
36 in. Minimum from Furniture
and Draperies
Mounting clearances as viewed
from front of heater (inches)
LEFT SIDE: 8 in.
Minimum
from Side of
Heater
RIGHT SIDE: 8 in.
Minimum
from Side of
Heater
LEFT SIDE: 8 in.
Minimum
from Side of
Heater
RIGHT SIDE: 8 in.
Minimum
from Side of
Heater
Fig. 9 - Minimum Clearance to
Combustible Material
Infrared model
Fig. 10 - Minimum Clearance to
Combustible Material
Infrared model
36 in. Minimum from Furniture
and Draperies
Away from the Other Side of the Heater
*A Second Side Wall Must be at Least 18 in.
A second side wall must be
min. 18 in. from the side of
the heater
CEILING: 36 in. Minimum
FLOOR: 1.25 in. Minimum to Top Surface of Carpeting
Tile from the Other Combustible Material
CEILING: 36 in. Minimum
FLOOR: 10 in. Minimum to Top Surface of Carpeting
Tile from the Other Combustible Material

CA-529- 2019-11-153
WARNING: Failure to position the parts in accordance with these
diagrams or failure to use only parts specically approved with
this heater may result in property damage or personal injury. See
instruction manual for further information.
Fig. 13 - Wall mounting
Infrared model
Support leg location
Support leg
screw (x4)
Fig. 12 - Optional leg mounts
Blue Flame model
Support leg (x2)
Fig. 11 - Wall mounting
Blue Flame model
FLOOR MOUNTING OF INFRARED MODEL NOT PERMITTED
Spacer(x2)
Rawl plug (x4)
Bracket
Spacer
Screw(x2)
Screw(x4)
Spacer(x2)
Rawl plug (x4)
Bracket
Spacer
Screw(x2)
Screw(x4)

CA-529-
2019-11-15
Keep burner and control compartment clean. See installation and operation
instructions accompanying heater.
This appliance may be installed in an aftermarket, permanently located,
manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible with other gasses.
This appliance shall not be eld converted
ANSI Z21.11.2-2016 Unvented Heaters
Model CA30000BL CA30000CL CA30000B CA30000C
Input Type 30,000 BTU 30,000 BTU 30,000 BTU 30,000 BTU
Gas Type LP LP NG NG
Manifold Pressure 10” WC 10” WC 5” WC 5” WC
Max. Inlet Pressure 14” WC 14” WC 9” WC 9” WC
Min. Inlet Pressure 11” WC 11” WC 7” WC 7” WC
Model CA30000BLF CA30000CLF CA30000BF CA30000CF
Input Type 30,000 BTU 30,000 BTU 30,000 BTU 30,000 BTU
Gas Type LP LP NG NG
Manifold Pressure 10” WC 10” WC 5” WC 5” WC
Max. Inlet Pressure 14” WC 14” WC 9” WC 9” WC
Min. Inlet Pressure 11” WC 11” WC 7” WC 7” WC
Fan Ratings 110-120V/60Hz
23W/1400RPM
110-120V/60Hz
23W/1400RPM
110-120V/60Hz
23W/1400RPM
110-120V/60Hz
23W/1400RPM
CAUTION: Hot while in operation. Do not touch. Keep children, clothing, and
furniture away.
CAUTION: Keep gasoline and other liquids having ammable vapors away.
This appliance is intended for supplemental heating.
This heater shall not be installed in a bathroom.
This heater shall not be installed in a bedroom.
3
Este manual sirve para los siguientes modelos
7
Tabla de contenidos
Otros manuales de Calentador de gas de SignitePro
Manuales populares de Calentador de gas de otras marcas

Superior
Superior BGE18NV Manual de usuario

Dru
Dru Room-sealed atmospheric gas-fired heating... Manual de usuario

klover
klover TKR 35 Manual de usuario

Rothenberger Industrial
Rothenberger Industrial 035984 Manual de usuario

New Buck Corporation
New Buck Corporation 34 Manual de usuario

Hargrove
Hargrove Timberland Glow Guía de inicio rápido