C. Remote Control Function
1, Remote Function
1-A) Lamp(Blue) turn on if remote S/W is turned on
1-B) The voltage is set from 0 to 10 volt according to input at the EXT
1-C) Output voltage displays according to the set value and the output is permitted
by external equipment(PC, PLC and etc).
1-D) Do not common the (-) on EXT input with (-) on DC output.
EXT input (+,-) 0-10V permit the independent control voltage.
1-E) If EXT, A point of output On/Off in Input or control terminal block should be
on to activate DC output
(Remote function is optional)
2. Local function
2-A) Lamp(Blue) will be turn off if remote s/w is at local.
2-B) Facial voltage volume control the voltage
3. Protection function
3-A) OVP function
If the set voltage is over, OVP Lamp(Yellow) will be on and the output voltage will
be automatically down.
Then, you need to turn off Power S/W and turn on after 2 or 3 seconds.
3-B) OCP function
If the set current is over, C/C Lamp(Red) will be turned on.
3-C) Fan Motor
Auto: If Heat Sint temperature is below 50 degrees Celsius, it's off. If not, it's on.
Manual: Fan Motor On(always)