Siemens AC5200 Manual de instrucciones

Siemens AB
Security Products
Access Control
AC5200
Quick Start Manual

Liefermöglichkeiten und technische Änderungen vorbehalten.
Data and design subject to change without notice. / Supply subject to availability.
© 2014 Copyright by Siemens AB
Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor. Der Empfänger erkennt diese Rechte
an und wird dieses Dokument nicht ohne unsere vorgängige schriftliche Ermächtigung ganz oder teilweise Dritten zugänglich machen oder
außerhalb des Zweckes verwenden, zu dem es ihm übergeben worden ist.
We reserve all rights in this document and in the subject thereof. By acceptance of the document the recipient acknowledges these rights
and undertakes not to publish the document nor the subject thereof in full or in part, nor to make them available to any third party without our
prior express written authorization, nor to use it for any purpose other than for which it was delivered to him.

3
Siemens AB
Security Products
10.2013
Contents
1Introduction .............................................................................................5
1.1 Power Supply............................................................................................5
1.2 Installation Overview.................................................................................5
1.3 AC5200 Exterior........................................................................................6
1.4 AC5200 Interior .........................................................................................7
1.5 AC5200 Mechanical ..................................................................................8
2Hardware Connection.............................................................................9
2.1 Basic Connection ......................................................................................9
2.2 Explanation of connectors.......................................................................10
2.3 Mounting the AC5200 .............................................................................11
2.4 Battery Installation...................................................................................11
3AC5200 Configuration ..........................................................................12
3.1 Upgrading an Entro SR34i or SR35i .......................................................12
3.2 Configuring Network Settings .................................................................13
3.3 Firmware Download ................................................................................14
3.4 License Download...................................................................................14
4Menu Navigation ...................................................................................15
5Keyword index.......................................................................................18

4
Siemens AB
Security Products
10.2013

Introduction
5
Siemens AB
Security Products
10.2013
1 Introduction
The AC5200 (ACC-Lite) is a smaller alternative to the ACC (Advanced Central
Controller) used in SiPass integrated. The AC5200 is based on the Entro
SR34i/SR35i controller and exists in two variations:
AC5200: 8 Door controller with preloaded ACC Firmware.
ACC-X – An Entro Controller upgraded with ACC Firmware. The X represents
the number of doors supported.
The AC5200 can be used with either ACC or Entro devices. However ACC-X con-
trollers can only be used with Entro devices, and are for migration sites.
This Quick Start Manual outlines how to install and configure an AC5200 controller
to work with SiPass integrated.
1.1 Power Supply
Ensure that the power supply is stable and within the rated voltage of the unit. Use
an uninterrupted power supply (UPS) to ensure a continuous function of the unit in
the event of power dips on the mains supply.
1.2 Installation Overview
The following is a list of items required to complete this installation:
AC5200 or Entro SR34i/SR35i Controller
12-24V power source
Ethernet cable
ACC FLN or Entro Devices + wiring
Optional items:
Modem + RS232 cable
The installation should proceed in this order:
1. Connect power to the AC5200.
2. Connect the FLN bus.
3. Connect the Ethernet.
4. Configure the network settings.
5. Create the AC5200 in SiPass integrated.

Introduction
6
Siemens AB
Security Products
10.2013
1.3 AC5200 Exterior
Fig. 1 AC5200 Exterior
AC5200 Exterior Items
Item Description
A LCD Panel. By default this displays basic information about the
controller but it can also be used to set system configuration.
B Keypad cover. When the AC5200 is unlocked and the doors
opened, this cover slides downward exposing a numeric keypad
that can be used to set basic options for the AC5200.
C Keylock. To open the AC5200 cover the correct key must be
used to unlock and provide mechanical access.
D Cover Door. The AC5200 provides two cover doors that can be
used to gain access to the connectors that allow devices (eg:
DC12 / D22 etc.) to be connected to an AC5200.

Introduction
7
Siemens AB
Security Products
10.2013
1.4 AC5200 Interior
Fig. 2 AC5200 Interior Diagram
Item Description
A Lock for use with supplied key. The middle of the front lid must be
pressed downwards before the left and rid lid can be opened.
B1, B2 Corner details that can be knocked out for hiding cable entry.
C Wall mounting screw holes. Remember to leave approximately
70mm space around the controller.
D Cable management mounting.
E RS485 bus connection for devices
F Not in use
G Not in use
H Socket for compact flash card (only supported for Entro upgrade)
I RS232 Modem / Diagnostics port
J 1st RJ45 Ethernet connection
K 2nd RJ45 Ethernet connection
L Battery socket, type CR2032.
M Display for showing and entering information
N Tamper switch

Introduction
8
Siemens AB
Security Products
10.2013
1.5 AC5200 Mechanical
Fig. 3 AC5200 Mechanical Layout

Hardware Connection
9
Siemens AB
Security Products
10.2013
2 Hardware Connection
This chapter explains how to connect up the power, communications and other
things to the AC5200 hardware.
2.1 Basic Connection
The following section outlines the basic tasks required to get the AC5200 up and
running.
Power Connection
The AC5200 requires a 12-24V power supply. Connect the power at terminals 1
and 2 of the AC5200.
Communication with devices
The AC5200 has one FLN to communicate with devices, which operates over
RS485. The following table explains what devices are available:
Controller Bus Protocol Devices Supported
AC5200 ACC FLN SRI (Single Reader Interface)
DRI (Dual Reader Interface)
ERI (Eight Reader Interface)
8IO (Eight Input / Output Module)
IPM (32 Input Module)
OPM (16 Output /16 Input Module)
Entro DC12 (Dual Reader Interface)
DC22 (Dual Reader Interface)
DC800 (Dual Reader Interface)
IOR6 (4 Input / 6 Output Module)
ACC-X Entro DC12 (Dual Reader Interface)
DC22 (Dual Reader Interface)
DC800 (Dual Reader Interface)
IOR6 (4 Input / 6 Output Module)
Connect your bus to COM A (terminal 4) and COM B (terminal 3).
Connect COM A to COM A and COM B to COM B for Entro devices
Connect +to COM A and –to COM B for ACC FLN devices
When using DRI (ADD5100) / ERI (ADE5300) / SRI (ADS5200) a 120 Ohm termi-
nation only at door control unit side is required. For DC12 / DC22 / IOR6 120 Ohm
termination on both ends, door unit and AC5200 controller side, is required.

Hardware Connection
10
Siemens AB
Security Products
10.2013
Communication with SiPass integrated
The AC5200 communicates with SiPass integrated via TCP/IP. Connect an Ether-
net cable to either of the available RJ45 Ethernet connections.
Peer to Peer communication between controllers is also done via TCP/IP.
2.2 Explanation of connectors
The following table explains of each of the available connectors on the AC5200.
Terminal Number Connector Label Description
1 12-24V + Positive connector for power source
2 Negative connector for power source
3 COM B RS485 bus connection for FLN/Entro
devices
4 COM A RS485 bus connection for FLN/Entro
devices
5 FRAME Signal screen for RS485 bus connec-
tion.
6 COM B Not in use
7 COM A Not in use
8 FRAME Not in use