Air quality sensor for indoor use.
SENSOAIR
INSTALLATION AND
OPERATING INSTRUCTIONS

SENSOAIR Installation and operating instructions
2 03.2017
Contents
1. Target group of this documentation...............................................................................................3
2. Intended use ...................................................................................................................................3
3. Safety notes....................................................................................................................................4
4. Description of device......................................................................................................................5
5. Installation ......................................................................................................................................6
6. Wiring diagrams for SENSOAIR plus ...........................................................................................11
7. Device control.................................................................................................................................13
8. Commissioning...............................................................................................................................15
9. Care and maintenance ..................................................................................................................15
10. Rectification of malfunctions........................................................................................................16
11. Technical specifications...............................................................................................................17
12. Information concerning product liability.....................................................................................18
13. Feedback on documentation....................................................................................................... 18
14. EU Declaration of Conformity with regard to CE marking ......................................................... 19

Installation and operating instructions SENSOAIR
03.2017 3
1. Target group of this documentation
•This documentation is intended for use by specialists and end users.
•All instructions concerning assembly, installation and repairs described in this document are to be
performed exclusively by electricians with training and practice in the installation, commissioning,
servicing and maintenance of home automation devices and electrical installation.
•All instructions on operation, care and maintenance as well as rectification of disturbance described
here are intended for specialists as well as end users.
•Following installation, the installation company must hand over the installation and operating
instructions to the end user.
2. Intended use
•The device is only to be used for measurement and control purposes in closed, dry and dust-free
rooms.
•Maintain a room temperature of 5 °C – 40 °C.
•This device is not suitable for use as a measuring device or as part of a gas warning or similar safety
device.
•Do not use solvents near the device.
•Silicon vapours can have an effect on how the device works.
•Use the unit only with original accessories from SIEGENIA.
•The device must always be installed by an experienced specialist, in accordance with the installation
and planning documents of SIEGENIA. The installation instructions in this document must be
complied with at all times.
•Use the unit only when it is in a technically sound condition.
Do not modify the device's components in any way.
•It must be ensured that indoor air is circulating round the SENSOAIR.
•Ensure that the device's ventilation openings are kept free and are not blocked by other equipment,
furniture or objects.
•The unit must be checked by a specialist in the event of a fault.

SENSOAIR Installation and operating instructions
4 03.2017
3. Safety notes
• This unit can be used by children aged 8 and above as well as by people with physical, sensory or
mental difficulties or with a lack of experience and knowledge as long as they are supervised or
have been instructed in how to use the unit safely and understand the resulting risks. Children must
not play with the unit. Cleaning and user maintenance must not be carried out by children without
supervision.
• Electrically operated unit. Risk of fatal injury from electric shock or fire.
To prevent personal injury or damage to property, always comply with the following instructions:
- Insert the Euro mains plug of the standard connecting cable only into a suitable 230VAC mains
power supply socket.
- If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, its
customer service or an equally qualified person to eliminate hazards.
- Only a qualified electrician may perform any work on the 230V AC mains power supply that is
required in order to connect the unit.
- All-pole safety isolation is required if the customer is routing the mains cable.
- Current local regulations (such as those of the VDE in Germany) must be observed.
- Relevant country-specific regulations must be strictly followed for all work carried out on the
voltage supply system or house wiring system.
- Do not connect the control line and low voltage connections of the device with the 230V
AC mains power supply. This can destroy all connected devices.
- Should a solid object or any liquid get inside the unit, stop operation immediately and
disconnect the unit from the mains power supply.
• Hazard due to third party attacks on SIEGENIA WLAN devices! Please observe the following notes
to protect your system against attacks by third parties:
- Every SIEGENIA WLAN device is protected by two passwords (user and administrator). It is
essential that you change these passwords after the initial setup. Do not leave in the default
setting.
- If the SIEGENIA WLAN devices are integrated in your home WLAN, this must be encrypted for
operation.
- Please choose secure passwords consisting of lower case and capital letters, numbers and
special symbols.

Installation and operating instructions SENSOAIR
03.2017 5
4. Description of device
The SENSOAIR is an air sensor for checking the quality of air in closed rooms.
4.1 Device types
SENSOAIR type plus smart
Table unit version −
Wall-mounted version
Measure/display CO2function
Measure/display VOC* function
Device control by cable via WLAN
* Volatile Organic Compound: In the form of gases, such as cigarette smoke, perspiration and kitchen odours etc.
4.2 Function
The quality of the air that has been measured is shown using an LED indicator (traffic light system).
LED indicator Signal Ventilation
Red Flashes 2x briefly Urgently required
Flashes 1x long
Red Permanently illuminated Required
Yellow/Red Permanently illuminated
Yellow Permanently illuminated Recommended
Green/Yellow Permanently illuminated Not necessary
Green Permanently illuminated
Red = Poor air quality – ventilation is required
Yellow = Medium air quality – ventilation is recommended
Green = The air quality is good

SENSOAIR Installation and operating instructions
6 03.2017
5. Installation
5.1 Installation requirements
• Suitable installation location:
- Ideally, use a wall-mounted outlet box
- Not in the immediate vicinity of windows, ventilation devices and people or animals
• A smooth and even wall
• Maintain a temperature of 5°C–40°C during installation
• During installation and before initial operation protect the device against:
- Dirt (e.g. cover ventilation grilles when wallpapering, etc.)
- Draught and directly exhaled air
- Direct sunlight
Exposed electrical components.
Danger due to short circuit or fire.
›Make sure that the power is isolated before installation.
›The fuses may need to be removed.
5.2 Additional requirements for SENSOAIR smart
• The SENSOAIR should be installed to be as free from interference as possible.
The following interferences can have a negative influence on the WLAN signal:
- Water lines
- Stone and concrete walls
- Metal objects
- Air conditioning units
- Wireless devices (e. g. radio telephones, baby monitors, Bluetooth loudspeakers, etc.)
- WLAN networks on the same wireless channels (e. g. the neighbour's WLAN router)
• If energy-carrying cables are routed in parallel to data cables (ISDN, DSL, etc.), this could lead
to interference e.g. in the speed of the data transmission.

Installation and operating instructions SENSOAIR
03.2017 7
5.3 Installation steps
1. Remove the casing cover
Note: In the delivered state, the cover is not clipped on. If it does need to be removed, insert a
suitable object (e.g. coin or screwdriver) into the gap in the retention catches and twist to lever
the cover off the casing.
2. Remove the pre-punched drill hole cut-outs and the power cable cut-out (depending on the
device) using a suitable tool:
a= Drill hole cut-outs
b= Power cable cut-out for 230 V AC
c= Power cable cut-out for 24 V DC
c
b
a
a

SENSOAIR Installation and operating instructions
8 03.2017
3. Pull the power cable through the relevant cable cut-out (bor c).
4. Position the bottom part of the casing and use it as a drilling template.
5. Drill the holes for wall mounting.
6. Fix the bottom part of the casing using two 4mm x 30mm screws and dowels (included).
7. Connect the power cable for 230 V AC or 24 V DC.
1 2 3 4
ON
b
c
230 V DC
24 V DC

Installation and operating instructions SENSOAIR
03.2017 9
8. Optional: Connect devices (SENSOAIR plus only).
- SENSOAIR plus controls the connected devices via 230 V AC or 24 V DC control lines.
- The devices are connected to a relay circuit board.
- For wiring diagrams see from Page 4
1 2 3 4
ON
Relay circuit board
Relay circuit board
Relay circuit board
Mains circuit board
Mains circuit board
Basic circuit board
(without mains circuit board)
24V DC control lines
230V AC control lines
230V AC / 24V DC