SICLI COP3000 Manual de usuario

Contents
Contents Page
1.0 Installation 3
Compatible Equipment 4
Detectors 4
Call Points 5
Beacons & Sounders 5
3 Channel I/O 7
1 Channel I/O 7
Zone Monitor Unit 8
4 Way Sounder Circuit Controller 9
Equipment Compatiblity 10
System Overview 12
Technical Specification 15
Optional Functions as per EN54 part 2 & 4 17
Cable and Wiring 21
Installation 22
Fixing details 23
External Connections 24
Networking 25
Inputs/Outputs 27
2.0 Panel Assembly Information 28
Attaching Panel Door 29
Installing Screen Door 30
Replacing Printer Paper Roll 31
Panel Fault finding 32
3.0 Appendix 33
4 Way Sounder Circuit COP4SIR 34
Zone Unit Monitor COPZMU-IS 35
1 Way I/O Unit COPMIO 36
Base CABB300 37
System Wiring 38
Loopsplitter 39
Internal Wall Sounder COPSYMPHONI 40
Base Sounder COPBS 41
3 Way I/O COPIO 42
Call Point COPBG-S, COPBG-SY, COPBG-WP 43
Serial Number Label Positioning 44
Battery Disposal 45
CE marking 46
www.acornfiresecurity.com
www.acornfiresecurity.com

COPP420 Analogue photoelectric sensor, this is the
most commonly used Sensor and is most suitable for
detecting slow burning fires.
The status LED can be programmed to either be
permanently off under normal conditions or to pulse in
order to confirm that it is in communication with the
COP3000 control panel.
COPOH450 Analogue photo/thermal sensor, this is a
new addition to the Cooper Fire Systems range of sensors.
It is the ideal Sensorfor a multi-use environment as it has
an excellent response to smouldering and fast burning
fires. photo/thermal sensors can be programmed for
thermal only operation at certain times of day
The status LED can be programmed to either be
permanently off under normal conditions or to pulse in
order to confirm that it is in communication with the
COP3000 control panel.
The range of compatible sensors for the COP3000 system consists of the following:
COPH430 Analogue heat sensor,
Heat sensors are suitable for dusty environments or
environments where smoke is likely to be present under
normal operating conditions. The CAH330 can be
programmed to operate in A1R, BS or CS mode of
operation depending on the required application and
sensitivity requirements.
The status LED can be programmed to either be
permanently off under normal conditions or to pulse in
order to confirm that it is in communication with the
COP3000 control panel.
Compatible Equipment
4
www.acornfiresecurity.com
www.acornfiresecurity.com

Compatible Equipment
Compatible callpoints
The range of purpose designed callpoints for COP3000 consists of a surface callpoint, a
flush callpoint and a surface weatherproof callpoint.
A range of accessories is available including a hinged protective cover, resettable
element kit and a flush bezel.
The status LED can be programmed to either be permanently off under normal
conditions or to pulse in order to confirm that it is in communication with the COP3000
control panel.
Compatible Sounders and Beacons
A wide range of loop powered sounders and beacons are available to operate with the
COP3000, consisting of a combined sounder base with a maximum output of 95 dB(A),
a standalone sounder with a maximum output of 100 dB(A) that is available in standard
or weatherproof versions and a stand alone loop powered beacon.
For applications where a discreet dedicated sounder is required, a cover plate is
available for the white base mounted sounder enabling it to be used as a stand alone
wall or ceiling mounted sounder.
All of these devices are fully programmable via the sophisticated COP3000 multi stage
cause and effect programming facilities.
All sounders have multiple selectable volume settings, the volume setting is controlled
by the COP3000 panel and so can be altered without needing to access the sounder.
COPBG-S
COPBG-SY COPBG-S
COPBG-SY
COPBG-WP
5
www.acornfiresecurity.com
www.acornfiresecurity.com

Base sounder
The CAS380 has been designed specifically to complement the latest generation of
Cooper Fire Systems soft addressed sensors.
it consists of a first fix bracket, and a main body which clips onto the bracket
incorporating the sounder and a Sensormounting base in a single composite assembly.
After the body has been clicked into place and connected, a Sensor or front cover is
then added to complete a very simple, quick and neat installation.
The cover enables the CAS380 to be used as a discreet stand alone wall or ceiling
mounted device.
The sounder base design incorporates a mechanism that can be activated if required to
lock either the Sensor or the cover into place to prevent unauthorised removal.
Dedicated Stand alone sounders
Stand alone sounders are ideal for applications where greater sound outputs are
required than can be achieved with a base sounder or for applications requiring a higher
level of resilience or ingress protection.
Two different versions are available standard version and an IP66 rated version.
COPBS
COPSYMPHONI
COPBS with Sensor fitted COPBS with CASC fitted
Compatible Equipment
6
www.acornfiresecurity.com
www.acornfiresecurity.com

Interfaces
COP3000 has been designed to be suitable for a wide range of applications, various
interfaces have been developed to enable the simple integration of other fire systems or
building control and safety systems. The following devices are available:
3 Channel I/O device. (COPIO)
COPIO has 3 input channels and 3 output channels, it is used to monitor up to three
separate inputs from equipment such as sprinkler flow switches and also to provide 3
separately controlled volt free output contacts which are intended to be used to control
external equipment such as air handling plant or access control systems.
All inputs and outputs operate completely independently of each other and can be
programmed using the sophisticated cause and effect capabilities of COP3000 to
operate either globally or in response to activation of specific devices or specific inputs.
Inputs are monitored for open and short circuits, a specific resistance is required to
activate an alarm condition, fully open or short circuit conditions are monitored and
generate a system fault signal.
Inputs are suitable for use as fire signal inputs such as from a sprinkler flow switch ,
however they can also be used to monitor non fire inputs such as external keyswitches.
Outputs are rated to switch a maximum of 1A resistive at 30V DC.
The COPIO is supplied in a surface mounting IP65 box.
1 Channel I/O device with mains rated switching capability
(COPMIO)
COPMIO is a single channel input / output unit, the output is capable of switching up to
1A at 230V AC.
Commonly used for applications such as door release controls and plant shut down
signalling
The input is monitored for open and short circuits, a specific resistance is required to
activate an alarm condition, fully open or short circuit conditions are monitored and
generate a system fault signal.
The input is suitable for use as a fire signal input such as from a sprinkler flow switch,
however it can also be used to monitor non fire inputs such as an external keyswitch to
activate day night mode or other panel functions
The COPMIO is supplied in a surface mounting IP65 box.
COPIO COPMIO
7
www.acornfiresecurity.com
www.acornfiresecurity.com

Zone monitor unit
COPZMU-IS is designed to enable a zone of compatible conventional sensors and
callpoints to be connected into the COP3000 loop,
For the compatibility refer to Sicli.
Please refer to local standards for details of the maximum allowable area to be covered
by a single zone. COPZMU-IS fixes to a standard, deep, double gang back box and can
be either surface or semi recess mounted. When semi recessed only the front section
protrudes giving a maximum 29mm depth.
Interfaces
COPZMU-IS
8
www.acornfiresecurity.com
www.acornfiresecurity.com

4 Way sounder circuit controller
COP4SIR provides power for 4 separately controllable conventional sounder circuits,
each circuit can be separately programmed.
COP4SIR is designed to greatly simplify installation in applications where specialist
sounders or beacons are required since it powers the sounders and allows full control of
the sounder operation without having to wire the sounder back to the COP3000 control
panel.
A 4 way unit takes up a single address but each circuit can be independently controlled.
A COP4SIR unit requires a local un-switched 230V supply and incorporates a back up
battery to 24 hours of standby operation followed by a minimum of 30 minutes of full
alarm ringing.
A standby of 72 hours can be achieved at the expense of reduced load capability.
Interfaces
COP4SIR
9
www.acornfiresecurity.com
www.acornfiresecurity.com

Equipment Compatibility
Relays / Auto-dialers and auxiliary equipment
A wide variety of relays and other equipment can be connected to the COP3000
system, but you should note the following constraints:
1) COP3000 provides monitored outputs to drive fire and fault relays mounted in
external equipment. External relays should be suppressed. If a non-suppressed
relay is used then a diode can be connected as shown in the wiring diagram in the
appendix, to suppress any reverse EMF on the release of the relay which might
cause the panel to malfunction.
2) A 24V DC output is provided at the panel to make it easy to connect ancillary
equipment. The panel can supply a continuous quiescent load of up to 100mA.
10
www.acornfiresecurity.com
www.acornfiresecurity.com
Tabla de contenidos