SENTRONIC VS133-P Manual de usuario

AI ToF People Counting
Sensor
VS133-P
User Guide
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

2
Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the
instructions of this operating guide.
Though the device is compliant with Class 1 (IEC/EN 60825-1:2014), please DO NOT look at
the ToF sensor too close and directly.
The device must not be disassembled or remodeled in any way.
To avoid risk of fire and electric shock, do keep the product away from rain and moisture
before installation.
Do not place the device where the temperature is below/above the operating range.
Do not touch the device directly to avoid the scalds when the device is running.
The device must never be subjected to shocks or impacts.
Make sure the device is firmly fixed when installing.
Do not expose the device to where laser beam equipment is used.
Use a soft, dry cloth to clean the lens of the device.
Declaration of Conformity
VS133-P is in conformity with the essential requirements and other relevant provisions of the CE,
FCC, and RoHS.
Copyright © 2011-2023 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual
shall copy or reproduce the whole or part of this user guide by any means without written
authorization from Xiamen Milesight IoT Co., Ltd.
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

3
Revision History
Date
Doc Version
Description
May 24, 2023
V 1.0
Initial version
Aug. 10, 2023
V 1.1
1. Add staff lanyard accessory;
2. Add multi-device stitching feature;
3. Add installation height detection feature;
4. Add DHCP feature;
5. Display HTTP/MQTT connection status and
support data re-transmission feature;
6. Add DST time feature;
7. Add ToF frequency setting.
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

4
Contents
1. Product Introduction ......................................................................................................................... 5
1.1 Overview ...................................................................................................................................5
1.2 Key Features ............................................................................................................................ 5
2. Hardware Introduction ...................................................................................................................... 5
2.1 Packing List ..............................................................................................................................5
2.2 Hardware Overview ................................................................................................................. 6
2.3 Reset Button ............................................................................................................................ 6
2.4 Dimensions (mm) .................................................................................................................... 7
3. Power Supply ..................................................................................................................................... 7
4. Access the Sensor .............................................................................................................................7
5. Operation Guide .................................................................................................................................9
5.1 Dashboard ................................................................................................................................9
5.2 Rule .........................................................................................................................................10
5.2.1 Basic Counting Settings ............................................................................................. 11
5.2.2 Multi-Device Stitching .................................................................................................14
5.3 Communication ..................................................................................................................... 18
5.4 Report ..................................................................................................................................... 21
5.5 System ................................................................................................................................... 21
5.5.1 Device Info .................................................................................................................. 21
5.5.2 User ..............................................................................................................................22
5.5.3 Time Configuration .....................................................................................................23
5.5.4 Remote Management .................................................................................................24
5.5.5 System Maintenance ..................................................................................................25
6. Installation Instruction .................................................................................................................... 26
6.1 Installation Height ................................................................................................................. 27
6.2 Covered Detection Area ........................................................................................................ 27
6.3 Environment Requirements .................................................................................................. 28
6.4 Installation ............................................................................................................................. 28
6.5 Factors Affecting Accuracy.................................................................................................. 31
7. Communication Protocol ................................................................................................................31
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

5
1. Product Introduction
1.1 Overview
VS133-P is a sensor that uses second-generation ToF technology to accurately count people.
This technology provides more precise depth maps and longer detection distances while
maintaining an excellent privacy protection rate. The advanced ToF technology combined with
an AI algorithm enables the sensor to handle complex scenes and distinguish non-human
objects with up to 99.8% accuracy. With easy installation, VS133-P is ideal for entrances or
corridors in retail stores, malls, offices, subways, and other locations.
1.2 Key Features
Up to 99.8% accuracy combining the 2nd generation ToF technology and AI algorithm
Allow to collect people counting data by differentiating between children and adults and
detecting staffs via identification features for clearer people analysis
Support the linking of multiple devices to expand coverage
Wider field angle to obtain longer-distance depth maps and cover a larger area
Working well even in low-light or completely dark environments with great lighting
adaptability
Free from privacy concerns without image capturing
Smart U-turn counting to filter redundant counting of people wandering in the area
High compatibility of data transmission from Ethernet port (HTTP/MQTT/CGI)
Various serial ports are equipped
Support local data storage and data retransmission to collect data securely
Easy configuration via Ethernet port for web GUI configuration
Quick and easy management with Milesight DeviceHub
2. Hardware Introduction
2.1 Packing List
1 × VS133-P
Device
4 × Ceiling Mounting
Kits
1 × Mounting
Sticker
8 × Staff
Tags
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

6
1 × Multi-interface
Cable
1 ×
Warranty Card
1 ×
Quick Guide
1 × VB01 Multifunctional
Bracket Kit(Optional)
8 × Staff Lanyards
(Optional)
If any of the above items is missing or damaged, please contact your sales representative.
2.2 Hardware Overview
2.3 Reset Button
Function
Action
LED Indication
Reset to Factory
Default
Press and hold the reset button for more than 10
seconds.
Green Blinks.
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

7
2.4 Dimensions (mm)
3. Power Supply
VS133-P can be powered by 802.3at PoE+. Choose one of the following methods to power up
the device.
Powered by a PoE Switch
Powered by a PoE Injector
4. Access the Sensor
VS133-P sensor provides user-friendly web GUI for configuration and users can access it via
Ethernet port. The recommended browsers are Chrome and Microsoft Edge. The default IP of
Ethernet port is 192.168.5.220 (can be found on the device label).
Step 1: Power on the device and connect the Ethernet port to a PC.
Step 2: Change the IP address of computer to 192.168.5.0 segment as below:
a. Go to StartControl PanelNetwork and Internet Network and Sharing
CenterEthernetPropertiesInternet Protocol Version 4 (TCP/IPv4).
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

8
b. Enter an IP address that in the same segment with sensor ( e.g. 192.168.5.61, but
please note that this IP address shall not conflict with the IP address on the existing
network);
Step 3: Open the Browser and type 192.168.5.220 to access the web GUI.
Step 4: Select the language.
Step 5: Users need to set the password and three security questions when using the sensor for
the first time (three questions can be skipped by refreshing webpage). After configuration, log in
with username (admin) and custom password.
Note:
1) Password must be 8 to 16 characters long, which contains at least two kinds or more in
combination with numbers, lowercase letters, uppercase letters and special characters .
2) You can click the “forgot password” in login page to reset the password by answering three
security questions when you forget the password if you set the security questions in advance.
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

9
5. Operation Guide
5.1 Dashboard
After logging on to the device web GUI successfully, user is allowed to view live video as follows.
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG

10
Parameters
Description
Reset Count
Clear all accumulated entrance and exit people counting values.
Output
Click to output a 5s high level signal from alarm out interface.
Alarm Output: dry contact, output=two contacts closure
Track
When enabled, there is tracking line when people pass the detection area.
Note: When working mode is Node mode, the device will not show people counting data.
5.2 Rule
VS133-P supports 3 working modes:
Standalone Mode: works as a standalone device to count people.
Master Mode: works as a master device to receive live view and tracks from other node devices.
One master device can connect 3 node devices at most.
056 222 38 18 mailbox@sentronic.com www.sentronic.com
SENTRONIC AG
Tabla de contenidos
Otros manuales de Sensor de seguridad de SENTRONIC