3 sec
to Exit
3 sec
to Exit
Selected
Value
Selected
Value
Selected
Value
3 sec to
Next Menu
3 sec to
Next Menu
3 sec to
Next Menu
3 sec to
Next Menu
3 sec to
Next Menu
3 sec
to Exit
3 sec
to Exit
valve will move
valve will move
valve will move
valve will move
3 sec to
Next Menu
3 sec to
Next Menu
valve will move
valve will move
3 sec to
Next Menu
3 sec to
Next Menu valve will move
valve will move
Change digit
Select digit
Confirm
Selected
Value
Selected
Value
Selected
Value
3 sec to
Next Menu
Press Enter to
select this function
3 sec to
Next Menu
Press Enter to
select this function
Press Enter to
select this function
Change digit
Select digit
Confirm
Smart Valve Positioner for
Linear or Rotary Valves
YES
YES
YES
YES
2
NO
3 sec
NO
3 sec
NO
3 sec
NO
3 sec
Preliminary Data
↑ ↓ 3 seconds to exit without change
↑ ↓ 3 seconds to exit without change
↑ ↓ 3 seconds to exit without change
3s
3s
3s
3s
3s
● Press Enter key ○ to select this option
5.1 – KP: Allows to adjust the proportional gain of the digital PID control from 0 to 50.
5.2 – TR: Allows to adjust the digital PID control integral time from 0.1 to 50 (s).
● If you want to quit the KP, Tr and Td setting, press the up arrow key ↑ for 3 seconds and
return to main menu.
5- PID
● When the value is ready, store it with the Enter key ○ and return to KP, Td and Tr setting to
set the other if you want.
5.3 – TD: Allows to adjust the digital PID control derivative time from 0 to 10 (s).
● Use up or down arrow keys ↑ ↓ to increase or decrease the value. Hold it to fast increase or
decrease.
● Use up or down arrow keys ↑ ↓ to select one option and press the Enter key ○.
In this menu function, you can manually set the parameters Proportional Gain (KP), Integral
Time (TR) and Derivative Time (TD).
●Use up or down arrow keys ↑ ↓ to increase or decrease the value. Hold it to fast
increase or decrease.
6.1 – E ALM: Enables positioner alarm on:
● When the value is ready, store it with the Enter key ○ and return to ‘’E ALM’’ setting
to set the other if you want.
● If you want to quit the ALARM setting, press the up arrow key ↑ for 3 seconds and
return to main menu.
In this menu function, it is possible to enable the alarm setpoint.
6.1.1 - LOWER: Allows to adjust the alarm range from 0 to 40% of the valve position.
6.1.2 – UPPER: Allows to adjust the alarm range from 60 to 100% of the valve position.
6- ALARM
6.2 – DESAB: Disable the alarm
● Press Enter key ○ to select this option
● Use up or down arrow keys ↑ ↓ to select one option.
● Press Enter key ○ to select the option"
● If you chose the "E ALM" option, use the up or down arrows to select ‘’UPPER’’ or
‘’LOWER’’ option and press the Enter key ○.
3s
In this menu function, it is possible to configure the valve action mode.
● Press Enter key ○ to select this option
● Press Enter key ○ to select the option.
7.2 - REVERS: Reverse action
● Use up or down arrow keys ↑ ↓ to select ‘’DIRECT or ‘’REVERS’’ option.
7.1 –DIRECT: Direct action
● If you are NOT SURE to proceed press up arrow keys ↑ 3 seconds.
● If you want to quit the ACTION options press the up arrow key ↑ for 3 seconds
and return to main menu.
● If you are SURE to proceed with the selected option press the Enter key ○.
7- ACTION
In this menu function, it is possible to define the operating mode of the valve.
8.1 - AUTO: The valve operates in automatic mode.
● Press Enter key ○ to select the option.
● If you select ‘’AUTO’’ confirm with the Enter key ○. The display will show SURE.
● Use up or down arrow keys ↑ ↓ to select ‘’AUTO or ‘’MAN’’ option.
● Press Enter key ○ to select this option
● If you are SURE to proceed with the selected option press the Enter key ○. The unit
executes the option and goes to the next menu.
8.2 - MAN: The valve operates in manual mode and can be moved to 0%, 25%, 50%,
75%, 100% and “ADJUST” (User Adjustable).
● When the value is ready, store it with the Enetr key ○ .
● On ‘’ADJUST’’ option use the up or down arrow key ↑ ↓ to increase or decrease value.
● Use up or down arrow keys ↑ ↓ to select one option option.
● There are five fixed options and one adjustable. Press the enter key ○ on the option desired.
● If you are NOT SURE to proceed press up arrow keys ↑ 3 seconds. The unit will go to the
‘’MAN’’ option.
● Press Enter key ○ to select the option.
● To quit the option and return to the main menu press up arrow key ↑ for 3 seconds.