SEI ADVISOR AE100 Manual de usuario

ENCODER / DECODER / RECORDER
PROGRAMMING AND INSTALLATION
seinnovators.com
SEI ADVISOR WALL MOUNT
SEI ADVISOR DESKTOP
SEI RECORDER

PRODUCTS 4
PROGRAMMING MAIN MENU 5
PROGRAM ENCODER 6
PROGRAM DTMF 7
PROGRAM DECODER 8
PROGRAM STACKS 9
VIEW/DELETE SLOTS 10
DELAY ADD/DELETE 11
DE-EMPHASIS ADD/DELETE 11
SOFTWARE VERSION 12
CLEAR MEMORY 12
CONFIGURE RELAYS FOR WAKEUP SEQUENCE 12
SET WAKEUP SEQUENCE TIMEOUT 12
SETUP 13
PROGRAM ALERT RELAY 13
ADD ALIAS 14
EXIT PROGRAM 14
SCHEMATIC 15
BOARD LAYOUT 16
INSTALLATION 18
SETUP AND PROGRAMMING 22
SCHEMATIC 30
BOARD LAYOUT 31
INSTALLATION 33
ADVISOR ENCODER / DECODER
RECORDER

SYSTEM MODULE INTERCONNECTIONS
MIC AUDIO FOR RECORDER 35
ADVISOR ENCODER / DECODER WITH MIC 36
AUDIO FROM MIC INTERCONNECT ADAPTOR
ADVISOR ENCODER / DECODER CONNECTED 37
TO ACCESSORY JACK
RECORDER CONNECTED TO ACCESSORY JACK 37
ADVISOR ENCODER / DECODER WITH RECORDER 38
CONNECTED TO ACCESSORY JACK
ADVISOR ENCODER / DECODER WITH RECEIVER 38
ALLOWS BASE STATION TO SCAN
ADVISOR ENCODER / DECODER WITH RECEIVER 39
AND RECORDER ALLOWS BASE STATION TO SCAN
RECORDER MOBILE INSTALLATION 39
ADVISOR WALL MOUNT RECEIVE ONLY 40
ADVISOR WALL MOUNT RECEIVE ONLY 40
WITH RECORDER
ADVISOR WALL MOUNT ENCODER / DECODER 41
ADVISOR WALL MOUNT ENCODER / DECODER 41
WITH RECORDER
ADVISOR WALL MOUNT ENCODER / DECODER 42
WITH RECEIVER ALLOWS BASE STATION TO SCAN
ADVISOR WALL MOUNT ENCODER / DECODER 42
WITH RECORDER AND RECEIVER ALLOWS
BASE STATION TO SCAN
ADVISOR DESKTOP EXTRA ENCODER / DECODER 43
WITH RECORDER
ADVISOR DESKTOP EXTRA ENCODER / DECODER 43
WITH RECEIVER ALLOWS BASE STATION TO SCAN
ADVISOR DESKTOP EXTRA ENCODER / DECODER 44
WITH RECORDER AND RECEIVER ALLOWS
BASE STATION TO SCAN
RECORDER WITH MIC AUDIO FROM MIC 44
INTERCONNECT ADAPTOR
RECEIVER SCHEMATIC 45
WARRANTY 46

*
*If the Recorder is slaved to the Advisor the Recorder will only record after the Advisor is tripped.
It is reset with the “*” on the Advisor key pad.
SEI
Advisor
Desktop
Extra
SEI Recorder
Station/Mobile
WIFI Connectivity
CLOUD Connectivity
SEI
Advisor
Wall Mount
SEI Receiver
SEI
Advisor
Desktop
ENCODING / DECODING / RECORDING
FOR PUBLIC SAFETY
TABLE OF CONTENTS

Hold for
6 Sec. PROGRAM
ENCODER
PAGE 6
PROGRAM
DTMF
PAGE 7
PROGRAM
STACKS
PAGE 9
PROGRAM
DECODER
PAGE 8
DELAY
ADD/DEL
PAGE 11
VIEW/DEL
SLOTS
PAGE 10
CLEAR
MEMORY
PAGE 12
EXIT
PROGRAM
MODE
Programming is intuitive. Just follow
the Screens.
Hold the “#” key for 6 seconds to En-
ter the Program Mode.
Use the “#” key to step through the
main options.
Use the “*” key to select the option.
“*” press WITH NO ENTRY, will return
to main Program Mode menu
To exit the Program Mode at any time
just hold the “#” key for 6 seconds.
Normal Screen
Displayed for 1.5 Sec.
SETUP
PAGE 13
DE-EMPHASIS
ADD/DEL
PAGE 11
PROGRAM
ALERT RELAY
PAGE 13
TABLE OF CONTENTS
CONFIGURE
RELAYS
PAGE 12
NEW WUS
TIMEOUT
PAGE 12

ALERT TONE
ADDED
Displayed for 1.5 Seconds
ADD ALIAS
PAGE 14
Select Program Encoder from the Pro-
gram Mode by pressing “*”.
Enter the Slot number you want to Pro-
gram.
Slots 0—999.
Enter the First Tone in the Two Tone Se-
quence. Include the Digit after the Deci-
mal Point. (For 853.4 Enter 8534)
Enter the Second Tone in the Two Tone
Sequence. Include the Digit after the
Decimal Point.
(For 1764.5 Enter 17645)
Select “Alert Tone” for an Alert Tone to
follow the Page.
The Slot Number will be Displayed for
1.5 Sec.
Tone A and Tone B will be Displayed.
Press “#” to Program the Slot.
(“*” TO Start Again)
Press “*” to enter a
16 character Alias for the Slot.
(See Instructions on Page 25)
For Group Call make the A Tone and the
B Tone the Same.
It will now Return to “Program Encoder”
to Program another Slot if Needed.
For 853.4
Enter 8534
For 1764.5
Enter 17645
Example
1764.5
Example
853.4
Example
452
TABLE OF CONTENTS

Select Program DTMF from the Program
Mode by pressing “*”.
Enter the Slot number you want to Pro-
gram.
Enter the number of DTMF Tones You
want to Send. (Min 1, Max 8)
Enter “1” for Standard DTMF, Enter “2”
for Knox F1 DTMF.
Enter the DTMF Digits One at a Time.
0 = 0 1 = 1 2 = 2 3 = 3 4 = 4
5 = 5 6 = 6 7 = 7 8 = 8 9 = 9
10 = * 11 = # 12 = A 13 = B 14 = C
15 = D
The Tones are then Displayed with the
Type. Press “#” to Program the Slot.
Press “*” to enter a 16 character Alias for
the Slot. (See Instructions on Page 25)
It will now Return to “Program DTMF” to
Program another Slot if Needed.
Displayed for 1.5 Seconds
Enter 1 - 8 (Example 5)
Enter 1 or 2 (Example 1)
Enter Digits One at a Time
(Example 3, 5, 9, 2, 8)
All Digits
Are Entered
ADD ALIAS
PAGE 14
ENTER THE SLOT NO.
THAT HOLDS THE
DTMF SEQUENCE
Example
238
PRESS # TO
ACCEPT THE
ENTRY
TABLE OF CONTENTS

Displayed for 1.5 Sec.
Select Program Decoder from
the Program Mode by press-
ing “*”.
Enter the Slot number you
want to Program.
Slots 1—100.
Enter the First Tone in the
Two Tone Sequence. Include
the Digit after the Decimal
Point. (For 853.4 Enter 8534)
Enter the Second Tone in the
Two Tone Sequence. Include
the Digit after the Decimal
Point. (For 1764.5 Enter
17645)
The Slot number will be Dis-
played for 1.5 seconds.
Tone A and Tone B will be Dis-
played. Press “#” to Program
the Slot.
Add WAKE-UP Sequence Op-
tion and select 1, 2 or 3.
Deactivate Relay Option
(Not Available if WAKE-UP Se-
quence or Add Re-Page are
Selected)
It will now Return to
“Program Encoder” to
Program another Slot if Need-
ed.
Enter 1, 2 or 3
Example
52
Example
853.4
Example
1764.5
For 853.4
Enter 8534
For 1764.5
Enter 17645
PRESS # TO
ACCEPT THE
ENTRY
TABLE OF CONTENTS

ADD ALIAS
PAGE 14
Displayed for 1.5 Sec.
Example
Slot 98
Step Through
all of the
Slots in the
Stack
Displays when End
of Stack is Reached
The Advisor will Accept up to 50
Stacks with up to 48 Slots in each
Stack.
Programming is Intuitive. Just fol-
low the Screens.
Enter the Slot number that will Hold
the Stack (Example 98)
Press # to Accept the Slot number
Enter the Slot number for Each Slot
in the Stack. (Maximum of 48 Slots)
Press “*” to enter a 16 character
Alias for the Slot. (See Instructions
on Page 25)
Press “#” to Review the Slots en-
tered into the Stack or Press “*” to
Finish.
Display the Slot number that Holds
the Stack.
Keep Pressing “#” to Step Through
each Slot in the Stack.
When the End of the Stack is
Reached you can choose to keep the
Stack or Delete it.
ENTER UP TO
48 SLOTS
NUMBERS
THIS IS THE SLOT THAT
WILL BE ENTERED TO
PAGE THE STACK
Displayed for
1.5 Sec.
TABLE OF CONTENTS

CODES: Tell What Decode Functions
are Programmed in the Slot
Enter a Slot
Number
Example 52
Displayed for 1.5 Seconds
NO
NO
ENTER
Enter a Slot
Number
Example 452
Displayed for 1.5 Seconds
If Slot is Two Tone If Slot is DTMF If Slot is a Stack
Displayed for 1.5 Seconds Displayed for 1.5 Seconds
Display Alias
Display DTMF
Digits
Display Alias
Step Through
all of the
Slots in the
Stack
YES
Return to
Program
Mode
Displayed for 1.5 Seconds
ENTER
KEEP
KEEP
KEEP
CODES
0 ALERT RELAY ONLY
2015 DEACTIVATE ALERT RELAY
20000 WAKE UP SEQUENCE 1
30000 WAKE UP SEQUENCE 2
40000 WAKE UP SEQUENCE 3
ALERT RELAY IS ACTIVE WITH WAKE UP SEQUENCE
KEEP
KEEP
YES
YES
Select from
Program Menu
TABLE OF CONTENTS
Este manual sirve para los siguientes modelos
10
Tabla de contenidos
Otros manuales de Convertidor de medios de SEI