© Copyright 2021 Seen Safety Limited. IRIS 860 Installation Guide. Version 2.3 5
Sensor mounting
The supplied stainless steel mounting bracket can be used on
horizontal, vertical, or angled surfaces. The sensor should be
mounted approximately 2 metres / 6-7 feet above the ground.
1. Choose mounting option A, B, or C as shown below.
2. Noting the required bracket orientation relative to the
sensor, securely attach the bracket to a solid surface using
appropriate M6 fasteners and torque settings.
3. Mount the sensor in the bracket as shown in the diagram.
Finger-tighten the four M6 screws (supplied) to hold the
sensor in the bracket. Adjust the sensor to the correct angle
using the sticker as a guide. (Refer to page 10 if using a
Weather Shield.)
4. Tighten the four M6 mounting screws to a maximum of 10Nm.
Note. An additional custom mounting plate may be required to
mount the IRIS 860 bracket in the required location.
WARNING. Do not drill into any roll-over or falling-object
protection structure (ROPS / FOPS) as this may compromise
the strength of the structure and void the machine warranty.
A. On top B. Underneath* C. Vertical**
27º
Correct angle
The sticker indicates
the correct angle
*Not compatible with a Weather Shield. Refer to page 10.
**The vertical mount option may not be suitable for installations
where multiple sensors are used because the sensor bracket
cannot be rotated to the required angle. Refer to page 12.
Alert volume
The 94dB alert may be uncomfortably loud if the sensor is
mounted close to the operator’s head. Options:
• Consider a Top Mount instead of an Underneath Mount.
• Set the sensor to Reduced Volume in the IRIS 860 setup app.
• Use SEEN’s snap-on volume reduction cap accessory.
35mm
130mm
70mm