Name
Table 1. Security grade
Supervisory window
1h
0 - 24h (0 = disabled)
Grade 1
Periodic supervision signal
every 1h
Grade 2
Custom
20 minevery 20 min
every 1h
Kodinis Raktas UAB, manufacturer of SECOLINK Intruder Alarm System, offers a Warranty for a term of
twenty-four months. It declares, that product complies with essential EU directives and EU standards EN
50131-1, Grade 1, Environmental Class II; EN 50131-2-2. For more information visit manufacturer’s
website www.kodinis.lt or www.secolink.eu for a complete text of declaration. SECOLINK Intruder Alarm
System is designed and manufactured in Lithuania.
The warranty is given in favor of the purchaser (hereunder the "Purchaser") purchasing the products
directly from Kodinis Raktas UAB (hereunder the "Kodinis Raktas") or from its authorized distributor.
During the warranty period, manufacturer shall, at its option, repair or replace any defective product upon
return of the product to its factory, at no charge for labor and materials. Repaired products shall be
warranted for the remainder of the original warranty period. The Purchaser assumes all responsibility for
the proper selection, installation, operation and maintenance of any products purchased from Kodinis
Raktas or from its authorized distributor. To obtain service under this warranty, please return the item(s) in
question to the point of purchase. All authorized distributors and dealers have a warranty program. All
transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned
to Kodinis Raktas for repair or replacement shall be borne solely by the Purchaser. Kodinis Raktas
warranty under this warranty does not cover products that is defective (or shall become defective) due to:
(a) alteration of the products (or any part thereof) by anyone other than Kodinis Raktas; (b) accident,
abuse, negligence, or improper maintenance; (c) failure caused by a product which Kodinis Raktas did not
provide; (d) failure caused by software or hardware which Kodinis Raktas did not provide; (e) use or
storage other than in accordance with Kodinis Raktas specified operating and storage instructions; (f) to
consumable parts, such as batteries or coatings that are designed to diminish over time. There are no
warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or
otherwise, which extend beyond the description on the face hereof. This limited warranty is the
Purchaser's sole and exclusive remedy against Kodinis Raktas and Kodinis Raktas sole and exclusive
liability toward the Purchaser in connection with the products, including without limitation – for defects or
malfunctions of the products. This warranty replaces all other warranties and liabilities, whether oral,
written, (non-mandatory) statutory, contractual, in tort or otherwise. In no case shall Kodinis Raktas be
liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether
occasioned by negligence of the Kodinis Raktas or any third party on its behalf) for breach of this or any
other warranty, expressed or implied, or upon any other basis of liability whatsoever. Kodinis Raktas does
not represent that these products can not be compromised or circumvented; that these products will
prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these
products will in all cases provide adequate warning or protection. Purchaser understands that a properly
installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other
events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur
or that there will be no personal injury or property loss or damage as a result. Consequently, Kodinis
Raktas shall have no liability for any personal injury; property damage or any other loss based on claim
that these products failed to give any warning. If Kodinis Raktas is held liable, whether directly or indirectly,
for any loss or damage with regards to these products, regardless of cause or origin, Kodinis Raktas
maximum liability shall not in any case exceed the purchase price of these products, which shall be the
complete and exclusive remedy against Kodinis Raktas.
Rev.30/09/20
6. SUMMARY
Type
Communication
Compatibility
Output type
Uses
Tamper input
Maximum load
Operating frequency
Wireless
Dual way, encrypted
EXT116VM (panels P16, P32, P64),
EXT116S (system module),
EXT11 (receiver for 3rd party systems)
Open collector type (makes „minus“)
Indoor
Yes (enabled by default)
50 mA / 12V DC
868,30 or 915,30 MHz depending on
the country of distribution
Communication range in
building
Periodic supervision
signal
Operating humidity
Power supply (Vdd)
Current consumption
(without load)
Supervisory window
Operating temperature
up to 100 m
20 min or 1h
up to 70%
+12V DC ± 15% (msg.: “low voltage” < 10V)
standby: ~13mA,
communication: ~25mA
1h ( ),Grade 1
20min (Grade 2),
0 - 24h (Custom)
o
from -10 up to +55 C
Overall dimensions 92 x 22 x 18 mm
SYSTEM COMPLIANCE & WARRANTY
Zone address
(BS100)
PGM output
No. in EXT Operation code
06
06
12
_
_
_
1
8
5
2
3
4
0
0
0
1
1
1
PGM address that
needs to be entered...
06
06
12
_
_
_
2
3
4
2
3
4
Table 3. Examples of PGM address
255
Delete single
254
Delete all
The same Operation code field is used to delete the particular BS100
or all BS100 from the particular module (module supports 4 x BS100):
5
4.3. SUPERVISORY WINDOW
The wireless device periodically sends a supervision signal to a
receiver. If the system does not receive supervision (or alarm signal)
signal from a specific device, the device is regarded as inactive. The
amount of time after which a device is considered inactive is called the
Supervisory window .
13
13
Z01 BS1 0 0
Super v isory wi n dow 1h
7
6. SETTING UP ADDRESS OF THE PGM OUTPUT
Service mode }System Setup }PGM outputs
O04 BS10 0
BS100
06_2
Name
Address
1
18
Burg lary ala rmDefi nition
2
3
CONTACT US
Manufacturer:
Company: UAB “Kodinis Raktas”
Address: Ateities str. 10, 08303 Vilnius, Lithuania
Tel.: +370 675 27275
Web: www.secolink.eu
Technical support:
Tel.: +370 659 28183
13 _1 13 _55015
1. Press [7] or [Ų] for a next PGM output.
2. Give an appropriate name to an output .
3. Enable PGM output by changing the Definition from Not Used to
any other depending on a specific of use.
4. Enter a wireless PGM output address in MA_P format , where MA
specifies a EXT116S or EXT116VM address in the system (where
BS100 is enrolled) and P specifies the which number was entered in
a OR it is the LAST digit of the field PGM output No. in EXT
Operation code which (see the wireless was used for enrolling
PGM addressing examples in Table ).3
16
17
18
8
5
16
17
5. All other PGM output settings are programmed like usual.
14
Wire less Su bsystem
Gra de 1
1 Secur ity grade
Main menu }Service Mode }System Setup }Wireless Subsystem
Supervisory window and periodic supervision signal sending are
directly related to selected security grade in the system (see Table 1).
14
15
Wire less se tting s
Mode ES (Energy Save)
2
Service mode}System setup}Wireless Subsystem
5. COMMUNICATION MODE SELECTION
Wireless d , starting from version supportevices 2.000 new commu-
nication mode, that can be selected in menu Mode :
15
Mode Distance Battery life
harsh environment for a signal to travel
(ex. concrete walls and ceilings);
long range;
less than 32 wireless devices in the system.
Application
suitable environment for a radio signal
to travel (ex. wooden walls);
middle range;
more than 32 wl. devices in the system;
Table 2. Mode comparison
LR
ES
The conflict can occur when ES is chosen in the system the mode
with older wireless device LR The the s that supports only the mode.
new setting will not be applicable and an error will be displayed on
screen upon changing the mode, on main screen, in the corresponding
user (LT5), wireless zone or module editing menu. All errors will be
displayed until all older wireless devices will be replaced (upgraded)
OR when Mode will be changed back to the LR .
15
15