Secabo TCC SMART Manual de usuario

OPERATING MANUAL
for the modular cap press
TCC SMART
Congratulations on the purchase of your Secabo heat press!
Please read this operating manual carefully to ensure a smooth production launch with your new
device.
Any type of reproduction of this operating manual requires the written permission of Secabo
GmbH. Modifications to and errors in the technical data and/or product characteristics are
reserved.
Secabo GmbH accepts no liability for any direct or indirect damages resulting from the use of this
product.
Version 1.0 (15.06.2018)
1

Safety Precautions
Please read the information and safety precautions carefully prior to first commissioning of the
device!
● Never reach inside the heat press with your hands when it is connected to the power
supply, especially if it is switched on and heated up – danger of burns!
● Never open the casing and do not make any modifications to the unit yourself.
● Should it be necessary to open the heat plate cover upon explicit request by Secabo's
customer service team, it is recommended you wear respiratory protection and only touch
the insulation wool located therein using gloves. Possible disposal of the insulation wool
should only be done inside a closed bag.
● Ensure that neither liquids nor metal objects reach the inside of the heat press.
● Make sure you use a grounded wall socket. Keep in mind that a heat press may only be
operated using a wall socket equipped with a ground fault circuit interrupter.
● Disconnect the heat press from the power supply when it's not in use.
● Always ensure that the heat press is out of reach of children during operation and never
leave the device unsupervised when switched on.
● Make sure the unit is only used in dry rooms.
If you cannot comply with one or more of the aforementioned safety rules, or if you are
unsure as to whether you're in compliance with all of the points, please contact our
technical support.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Germany [email protected] www.secabo.com
2

Items included
Mechanical base of the heat
press with heating element and
base element
Controller box
C13 Cold device cable

Machine description
a. Main switch (not shown)
b. LCD display
c. Control panel with push buttons and rotary pushbutton
d. Power socket and ground connection Controller (not shown), internal connections
e. Clamping lever for transfer objects
f. Exchangeable base element
g. Heating element and heating element cover
h. Press lever
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Germany [email protected] www.secabo.com
4

Installation and commissioning
● Safely set up the TCC SMART heat press on a stable table.
● Position the controller box at the upper rear center of the base frame of the TCC SMART
heat press and let the threaded bolts at the controller box slide into the slots at the base
frame. Securely tighten the hand nuts.
● Attach the small 6-pin plug from the rear side of the base frame to the appropriate socket
on the outer right side of the controller box.
● Attach the large 5-pin plug from the surface of the heating element to the appropriate
socket on the right outer side of the controller box.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Germany [email protected] www.secabo.com
5

● Plug the PE conductor cable from the HPC01 Controller into the rear of the terminal at the
base frame provided for this.
● Plug the supplied C13 cold device cable into the back of the controller box and connect it to
a safety socket, which must be equipped with a grounded connection, protection via fuse
and ground fault circuit interrupter.
The TCC SMART heat press is now ready for use.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Germany [email protected] www.secabo.com
6

Controller components and operation
Display components and their meaning
Area for time setting and countdown when press is closed

Area for time setting and activity indicator of the pre-press feature
Icon for the Bluetooth connection
General indicator for fault or error
Area for temperature indicator for target temperature and actual
temperature
Indicator heat plate's heating active
Indicator press is done heating up
Indicator press is currently heating up or cooling down. Below the
set temperature, the arrow is flashing upwards.
Indicator for management of memory slots
Counter for counting the performed press operations
How to use the controller
Initial setup when first switched on
When switching on the HPC01 controller for the first time, the language selection appears.
Select the appropriate language for you by turning the rotary knob to the desired language
and confirm by pressing.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Germany [email protected] www.secabo.com
8

Now select the desired unit for temperature - °C or °F - by turning the rotary knob to the
desired unit and confirm by pressing.
This initial setup will no longer be displayed when switching the transfer heat press on in
the future.
To reset the HPC01 controller to factory settings, simultaneously press the
button as well as the button for 3 seconds.
Setting the temperature
Briefly press , the symbol in the display begins to flash. The value in the
display changes from the current ACTUAL value to the TARGET value, which can
now be set. Turn clockwise to increase the TARGET temperature, counter-clockwise
to decrease. Press the rotary knob or press to store the set value. If no input
occurs for 5 seconds, input mode ends automatically. Pressing exits input mode,
the set value is not applied and the display returns to the current ACTUAL value.
Temperature-related indicators
is activated whenever the heater is running.
During the warm-up phase, every 10s an estimated remaining warm-up time scrolls across
the display for 3s instead of the current temperature.
is activated when the actual temperature is equal to the target temperature, with a
certain deviation of less than +/- 3 °C.
Arrow up is activated when the temperature is rising (if below TARGET temperature,
arrow is blinking), arrow down is activated when the temperature is dropping, e.g. during a
transfer or if the heat plate is still hotter than the set target temperature.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Germany [email protected] www.secabo.com
9

Is generally activated in the event of faults or errors, and when there is a significant
deviation between TARGET and CURRENT temperature (value outside of a range that
allows for useful pressing).
Setting the time
Briefly press , symbol in the display flashes. Turning the rotary knob clockwise
increases time, counter-clockwise decreases. Press the rotary knob or press to
store value. If no input occurs for 5 seconds, input mode ends automatically. Pressing
will exit the input mode, the display will return to its original value.
Configuring pre-pressing
Briefly pressing activates pre-pressing for the following press operation using
the preset time, and is deactivated again upon completing the press operation. When
activated, the Time + Pre symbols will light up in the lower part of the display with the
corresponding time indicator. This will count down to 0 while pressing, whereupon the
symbol and time switched off again.
Holding activates the setting mode for the PRE time analog with time setting:
Symbol in the display flashes. Turning the rotary knob clockwise increases time,
counter-clockwise decreases. Press the rotary knob or press to store value. If
no input occurs for 10s, input mode ends automatically. Pressing will exit the
input mode, the display will return to its original value.
Pre-pressing can be activated permanently from the settings menu. More information
below.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Germany [email protected] www.secabo.com
10
Tabla de contenidos
Otros manuales de Herramientas eléctricas de Secabo

Secabo
Secabo TM2 Manual de usuario

Secabo
Secabo TC1 Manual de usuario

Secabo
Secabo TC5 Smart Manual de usuario

Secabo
Secabo TC D2 Manual de usuario

Secabo
Secabo TCC Lite Manual de usuario

Secabo
Secabo TB7 Manual de usuario

Secabo
Secabo TS5 Economy Manual de usuario

Secabo
Secabo TC5 Smart Manual de usuario

Secabo
Secabo TMUG Manual de usuario

Secabo
Secabo TC5 Smart Manual de usuario