PAC3760 plus II
Operating Instructions
1
PAC3760 plus II
Operating Instructions
Represented in Australia by:
EMONA Instruments Pty Ltd
78 Parramatta Rd
Camperdo n NSW 2050
Tel: 1 800 632 953
.emona.com.au, .protag.com.au
Represented in Ne Zealand by:
Electrotest Ltd
12A Te Kea Place
Albany
Auckland
Tel: +64 (09) 4482600
.electrotest.co.nz
Part Number 372A567 Revision 1
© 2010 Sea ard Electronic Ltd

PAC3760 plus II
Operating Instructions
2
Limited Warranty & Limitation of Liability
SEAWARD Electronic Limited guarantees this
product to be free from defects in material and
orkmanship under normal use and service for a
period of 1 year. The period of arranty ill be
effective at the day of delivery.
(c) Copyright 2010
All rights reserved. Nothing from this edition may be
multiplied, or made public in any form or manner,
either electronically, mechanically, by photocopying,
recording, or in any manner, ithout prior ritten
consent from SEAWARD Electronic Limited. This
also applies to accompanying dra ings and
diagrams.
Due to a policy of continuous development
SEAWARD Electronic Limited reserves the right to
alter the equipment specification and description
outlined in this publication ithout prior notice and
no part of this publication shall be deemed to be
part of any contract for the equipment unless
specifically referred to as an inclusion ithin such
contract.

PAC3760 plus II
Operating Instructions
3

PAC3760 plus II
Operating Instructions
4
DECLARA ION OF CONFORMI Y
As the manufacturer of the apparatus listed, declare
under our sole responsibility that the product:
PAC3760 plus II
To hich this declaration relates are in conformity
ith the relevant clauses of the follo ing standard:
IEC 61010-1:2001
Safety requirements for electrical equipment for
measurement, control, and laboratory use – Part
1: General requirements.
IEC 61326:2005
Electrical equipment for measurement, control
and laboratory user-EMC Requirements
Performance: The instrument operates ithin
specification hen used under the conditions in the
above standards EMC and Safety Standards.
The product identified above conforms to the
requirements of Council Directive 89/336/EEC and
73/23 EEC.
Sea ard Electronic Ltd is registered under BS EN
ISO9001:2000 Certificate No: Q05356.

PAC3760 plus II
Operating Instructions
5
Contents
1
Important Information ...................................... 6
2
Introduction ...................................................... 8
3
Performing Tests.............................................. 9
3.1 Testing a Class I Appliance .............................................. 9
3.2 Testing a Class I Appliance ith Leakage....................... 11
3.3 Testing a Class II Appliance............................................ 13
3.4 Testing a Class II Appliance ith Leakage...................... 14
3.5 Testing a mains cord ...................................................... 16
3.6 Testing an extension lead............................................... 17
3.7a Test an EPOD (Po erboard) ......................................... 17
3.7b Test an EPOD/Extension Lead ith MOV and/or RCDs 18
3.8 Testing 3-Phase equipment............................................ 20
3.9 Testing RCD Operating Time.......................................... 20
4
Troubleshooting ............................................. 23
5
Specification................................................... 24
6
Maintenance................................................... 25
7
Battery Check ................................................ 26
7.1
Battery Replacement ................................................. 26
8
Fuse................................................................ 27
8.1
Fuse Replacement..................................................... 27
9
Service and Calibration .................................. 28

PAC3760 plus II
Operating Instructions
6
1 Important Information
These operating instructions are intended for the
use of adequately trained personnel.
The follo ing symbols are used in these operating
instructions and on the PAC3760 plus II.
Caution, risk of electric shock.
Indicates instructions must be followed
to avoid danger to persons.
Caution, risk of danger. he operating
instructions must be adhered to in order
to avoid danger.
Caution, risk of electric shock.
Always ensure that the equipment under
test is disconnected from any supply
before connecting to the PAC3760 plus II.
It is the responsibility of the user to ensure that the
operation of the unit is correct and that the accuracy
of the measurements are ithin specification.
Before use, ensure unit is clean and dry; visually
inspect all leads, connectors, and case. Any
damage or ear must be rectified prior to use.
Standard Accessories
Part Number
Carry Case 71G082
Mains Supply Test lead 44B165
Black Continuity/Earth Test
Lead 1m
161A024
Australian IEC mains cord 0.5m
325A005
Optional Accessories
Part Number
Leakage test 3-Phase Adaptor 372A950

PAC3760 plus II
Operating Instructions
7
Figure 1. PAC3760 plus II Front Vie
Figure 2. PAC3760 plus II End Vie

PAC3760 plus II
Operating Instructions
8
2 Introduction
The PAC3760 plus II is a hand held battery po ered
unit suitable for carrying out electrical safety checks
on:
•Class I appliances
•Class II appliances
•IEC mains leads
•Extension leads
•10mA portable RCD
•30mA portable RCD
•3 Phase appliances hen used ith a 3-
Phase Adaptor
Overview
With reference to Figures 1 and 2.
1. The LCD
2. Class I Test / Cord Sequence Button
3. Class II Test Sequence Button
4. Leakage Test Sequence Button
5. 10mA portable RCD Test Button
6. 30mA portable RCD Test Button
7. 3-Phase Test Sequence Button
8. Test/Mains outlet socket
9. Mains inlet socket
10. IEC Test Connection
11. Earth Continuity Test Terminal
User Interface
The LCD display sho s test progress, results for
individual tests and the overall test result for an
appliance or mains cord.
Measurements displayed next to the R
PE
icon
indicate the resistance of the protective earth
conductor.
Measurements displayed next to the R
ISO
icon
indicate the resistance measured by the insulation
test.

PAC3760 plus II
Operating Instructions
9
Measurements displayed next to the I
LEAK
icon
indicate the leakage current measured hile the unit
is po ered from a mains supply.
Tests are initiated using the six push buttons.
Po er ON/OFF = press and hold the Class I and
Class II test buttons simultaneously, PAC3760 plus
II ill po er on/off hen buttons are released.
Note: he unit will automatically switch OFF
after approximately 3 minutes if no keys
are pressed.
3 Performing ests
Press keys Class I and Class II test buttons together
to s itch on the unit. When the unit is ready the
display ill be as sho n belo .
3.1 esting a Class I Appliance
Visually inspect the appliance as per requirements
of AS/NZS 3760:2010. If the appliance passes a
visual inspection proceed ith the electrical tests.
Plug the earth test lead into the Earth Continuity test
terminal on the PAC3760 plus II end panel.
Plug the appliance into the PAC3760 plus II front
panel test socket.
Connect the earth test lead to an exposed metal
part on the appliance.

PAC3760 plus II
Operating Instructions
10
If the Appliance under test has an ON/OFF s itch,
make sure it is in the ON position.
Press the Class I test button to start a Class I test
sequence.
The PAC3760 plus II ill no test the continuity of
the protective earth.
If the measured value is greater than the 1 ohm
pass/fail threshold, the measured value is displayed
and the unit indicates a fail result as sho n belo .
If the measured value is less than or equal to the 1
ohm pass/fail threshold, the measured value is
displayed and the unit indicates a pass result, as
sho n belo .
If the Earth Continuity test has passed then the unit
ill proceed ith an Insulation test.
Note: he power switch on the appliance under
test must be in the ON position to perform
an insulation test. If no appliance is
Tabla de contenidos
Otros manuales de Equipo de prueba de SEAWARD Electronic
Manuales populares de Equipo de prueba de otras marcas

SMART
SMART KANAAD SBT XTREME 3G Series Manual de usuario

Agilent Technologies
Agilent Technologies BERT Serial Manual de usuario

Agilent Technologies
Agilent Technologies N3280A Manual de usuario

Vernier
Vernier Go Direct Voltage Manual de usuario

Lifeloc
Lifeloc R.A.D.A.R. Manual de usuario

Fluke
Fluke T5-600 Instrucciones de funcionamiento e instalación