scope Centaur BC070-CB Manual de usuario

SKOPE Centaur Series
Horizontal and Vertical Chillers and Freezers
User Manual
MAN11086 Rev.5.0 Nov. 2018


CONTENTS
1 Models
Undercounter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Sandwich. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pizza . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Vertical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Installation
Safety First . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Locating the Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Positioning the Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Castors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Adjustable Height Legs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Shelving. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Gastronorm Containers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sandwich and Pizza Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Drawer Cabinets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Operation
Automatic Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Power Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Refrigeration Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electronic Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electronic Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Stand-by Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Temperature Setpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Controller Messages and Alarms . . . . . . . . . . . . . . . . . . . . . . . . . 13
4 Maintenance
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

SKOPE Centaur Series
User Manual 4
1Models
Undercounter
Sandwich
Pizza
Vertical
Model Type Part No. Doors Operating temperature
range
BC070-CB
Chiller
B070CB-1ROOS-E 1 × solid door
1°C to 4°C up to 38°C
ambient
BC090-C B090-C-1ROOS-E 1 × solid door
BC090-CS B090-CS-3ROOS-E 3 × drawers
BC120-C B120-C-2RROS-E 2 × solid door
BC180-C B180-C--3RRRS-E 3 × solid door
BC180-CS B180-CS-6RROS-E 6 × drawers
BC120-CG B120-CG-2RROS-E 2 × glass door 1°C to 4°C up to 32°C
ambient
BC180-CG B180-CG-3RRRS-E 3 × glass door
BC120-C Freezer B120-C-2FFOS-E 2 × solid door -23°C to -18°C up to 38°C
ambient
BC150-C Chiller/Freezer B150-C-2FROS-E 2 × solid door
Chiller: 1°C to 4°C up to
38°C ambient
Freezer: -23°C to -18°C up
to 38°C ambient
Model Type Part No. Doors Operating temperature
range
BC120-S
Chiller
B120-S-2RROS-E 2 × solid door 0°C to 5°C for up to 4
hours in 30°C ambient
(with hinged pan covers
raised)
BC180-S B180-S-3RRRS-E 3 × solid door
Model Type Part No. Doors Operating temperature
range
BC180-P
Chiller
B180-P-2RROS-E 2 × solid door 0°C to 5°C for up to 4
hours in 30°C ambient
(with hinged pan covers
raised)
BC240-P B240-P-2RRRS-E 3 × solid door
BC240-PS B240-PS-22RRRS-E 2 × solid doors
and 2 × drawers
Model Type Part No. Doors Operating temperature
range
BC074 Chiller B074-1ROOS-E 1 × solid door 1°C to 4°C up to 38°C
ambient
BC126 B126-2RROS-E 2 × solid doors
BC074 Freezer B074-1FOOS-E 1 × solid door -23°C to -18°C up to 38°C
ambient
BC126 B126-2FFOS-E 2 × solid doors
BC126 Chiller/Freezer B126-2RFOS-E 2 × solid doors
Chiller: 1°C to 4°C up to
38°C ambient
Freezer: -23°C to -18°C up
to 38°C ambient

5
SKOPE Centaur Series
Installation
User Manual
2Installation
Safety First Always observe safety precautions when using any electrical appliance.
Read these instructions carefully and retain them for future reference.
When the appliance is used by or near young children or infirm persons,
close supervision is necessary, especially to ensure children do not play
with it.
Do not use this appliance for other than its intended use.
Do not cover the grilles or block the entry or exhaust of airflow by
placing objects up against the refrigeration unit.
Do not probe any opening.
Only use this appliance with the voltage specified on the rating label.
Ensure the appliance has adequate ventilation as this is essential to
economical, high performance.
Be careful not to touch moving parts and hot surfaces.
For your own safety and that of others, ensure that all electrical work is
done by authorised personnel.
If the power supply flexible cord becomes damaged, it must be replaced
by an authorised service agent or similarly qualified person in order to
avoid a hazard.
Ensure all necessary safety precautions are observed during installation
or removal of the refrigeration unit.
The appliance is not designed to be stable while in motion. Use extreme
caution when moving or transporting it.
Do not store explosive substances such as aerosol cans with a
flammable propellant in this appliance.
Please contact SKOPE customer services for advice regarding disposal
of this appliance.
CAUTION
Never overload the power supply, which could damage the
cabinet and product. See the rating label inside the cabinet for
the safe power supply and current draw.
WARNING
Always disconnect the cabinet from the mains power supply
before any cleaning or maintenance.

6Installation
User Manual
SKOPE Centaur Series
Locating the Cabinet
Location When positioning the cabinet, avoid direct sunlight and warm draughts etc,
and areas where the refrigeration unit could be exposed to water or
moisture. The cabinet must NOT be situated where it is affected by warm or
hot air from adjacent equipment, as this will compromise the airflow and
performance of the cabinet. This chiller is designed to operate within a
specific climatic class environment (see cabinet rating label for climate class
number).
Climate Classes
The cabinet must be positioned on a level surface for the doors to shut and
seal correctly, and to prevent the condensate tray from overflowing.
Adequate allowance should be made for door and/or drawer opening.
Sandwich and Pizza cabinets have pan openings with hinged pan covers on
the top of the cabinet. Maximum air movement around the opening area of
the cabinet must not exceed 0.3 m/s. Excessive air movement will cause
failure of the air curtain above the pans and excessive temperature rise.
When installing the cabinet
Ensure all packaging is removed from the cabinet.
Avoid direct sunlight and warm draughts etc.
Allow adequate space for the door/s and/or drawer/s to open fully.
Ensure the cabinet is positioned on a level surface so the door/s shut
and seal correctly and to prevent the condensate tray from overflowing.
Air movement above Sandwich and Pizza cabinets must not exceed 0.3
m/s.
Ventilation It is critical that the hot refrigeration exhaust air is not restricted and that it
can easily flow out and away from the front of the cabinet. Never store
cardboard cartons or other items in front of or on top of the refrigeration unit.
The ventilation slots on the refrigeration unit front cover and at the rear of
the cabinet must be kept clear at all times. Normal operating conditions
should not exceed the operating temperature range (see page 4).
Horizontal cabinets (undercounter, sandwich and pizza)
Ensure there is always at least a 150mm gap around the back and the
refrigeration unit side of the cabinet.
Vertical cabinets
Ensure there is always at least a 150mm gap around the back and sides of
the cabinet, and at least 500mm above the cabinet.
Power Supply The cabinet is supplied with a flexible power cord and plug which exits the
rear of the cabinet.
Before final positioning of the cabinet, pull the power cord out from the rear
compartment and connect to the power supply. For convenience, any
surplus cord length may be left inside the cabinet compartment.
Climate Class Ambient Temperature Relative Humidity (RH)
325°C 60%
430°C 55%
540°C 40%
WARNING
Do NOT overload the power supply. See the rating label inside
the cabinet for power supply and current draw.

7
SKOPE Centaur Series
Installation
User Manual
Positioning the Cabinet
The cabinet is fitted with a set of four swivel castors, and is supplied with a
set of four adjustable height legs, which can be fitted in place of the castors
depending on specific height and manoeuvrability requirements. The legs or
castors should be fitted to the base of the cabinet before final positioning.
Castors The castors screw into the castor mounting plates on the bottom of the
cabinet. Where castors are fitted, the two lockable castors should be fitted
to the front of the cabinet and the non-locking castors fitted to the rear.
Adjustable
Height Legs
The adjustable height legs screw into the castor mounting plates on the
bottom of the cabinet. Remove the castors to fit the legs.
Rotate the bottom section of the legs to adjust the height. The legs can be
used to raise the cabinet between 100mm and 160mm above the floor.
To adjust leg height
Refer to the table below for the adjustable height leg part number.
Adjustable height leg part number
1. Turn the plastic foot at the bottom of the leg clockwise to increase, or counter-
clockwise to decrease the height.
Item description SKOPE part number
Centaur adjustable height leg BC-AJL03-00

8Installation
User Manual
SKOPE Centaur Series
Shelving
The cabinet is supplied with shelves and shelf support brackets which can
be positioned at different heights to suit various products.
To fit the shelves
The cabinet should be left running for 30 minutes before loading with
product.
When loading product
Allow air space around all the product to ensure even cooling and
efficient operation of the cabinet.
Do not allow products to overhang the front of the shelf as this could
prevent the doors from shutting. Leave an airspace of at least 75mm
above product loaded on the top shelf.
Do not exceed a maximum loading of 20kg per shelf.
Remove some product if the shelves are flexing or bending.
1. Unpack the shelving items from inside the cabinet.
2. Establish the desired position for each of the shelves, based on the height of
the product intended to go on each shelf.
3. Fit the shelf support brackets into the corresponding slots in both the front
and back support strips. Each shelf requires four support brackets.
4. Sit each shelf on the support brackets.

9
SKOPE Centaur Series
Installation
User Manual
Gastronorm Containers
Sandwich and
Pizza Cabinets
Sandwich and Pizza cabinets are supplied with gastronorm food preperation
containers which fit into openings on top of the cabinet, and hinged covers.
Refer to the tables below for standard container and hinged cover quantities:
Sandwich cabinet
Pizza cabinet
For correct operation of the cabinet, the hinged covers must stay closed to
cover the food preparation containers when not in use. The maximum
recommended operating ambient temperature for Sandwich and Pizza
cabinets is 30°C. Leaving the covers raised for more than 4 hours at the
maximum operating temperature will compromise the performance of the
chiller.
Drawer
Cabinets
Drawer cabinets are fitted with dividers designed to fit various 150mm deep
gastronorm containers, as shown below. Containers are not included with
the cabinet.
Model Doors Pans Hinged covers
BC120-S 2 doors 6 × 1/3 refrigerated containers
(176mm wide × 325mm deep) 1
BC180-S 3 doors 9 × 1/3 refrigerated containers
(176mm wide × 325mm deep) 1
Model Doors/Drawers Pans Hinged covers
BC180-P 2 doors 9 × 1/3 refrigerated containers
(176mm wide × 325mm deep) 2
BC240-P 3 doors 12 × 1/3 refrigerated containers
(176mm wide × 325mm deep) 3
BC240-
PS
2 doors and 2
drawers
12 × 1/3 refrigerated containers
(176mm wide × 325mm deep)
(drawer pans not included)
3
IMPORTANT
The hinged pan covers should be closed when the pans are not
in use. Leaving the covers open for extended periods will
compromise performance of the cabinet.
1/4
1/4
1/1 1/1 1/1 1/11/1 1/1 1/1
BC090-CS
3 × refrigerated
stainless steel
drawers
BC180-CS
6 × refrigerated
stainless steel
drawers
BC240-PS
2 × refrigerated
stainless steel
drawers

10 Operation
User Manual
SKOPE Centaur Series
3Operation
Automatic Start-Up
Connect the cabinet to the mains power supply and check operation of the
refrigeration unit and electronic controller. Ensure the cabinet power switch
is turned on.
Power Switch The cabinet is fitted with a power switch, usually located beside the
electronic controller. Depending on the model, it may be necessary to open
the unit front cover to access the switch.
Refrigeration
Unit
The compressor, and the condenser and evaporator fans should all operate
within two minutes from the time the cabinet is plugged in. This may be
verified by listening for compressor switch-on and checking for air
movement inside the cabinet. The compressor and condenser fan will switch
off when the cabinet internal air reaches a pre-set temperature.
Electronic
Controller
When the cabinet is connected to the power supply, the electronic controller
will display the current cabinet temperature. The compressor symbol will
come on after a few minutes, indicating the compressor and condenser fan
is operating.
To ensure efficient operation, the electronic controller forces regular
defrosts. During the defrost cycle, the compressor and condenser fan switch
off and the evaporator fan stays on.
IMPORTANT
If the cabinet has been on its back, leave for 30 minutes
before running.
Este manual sirve para los siguientes modelos
15
Tabla de contenidos
Otros manuales de Congelador de scope