Schlagel EDI CONTROL 7 Manual de usuario

SCHLAGEL, INC.
EDI Distributor Control 7
Page 1 of 1
New Features
Smaller size 10x8x5
Water and dust tight
Menu system for customizing
Automated configuration
Integrated Terminal/ ontrol
Spout Directory eliminates charts
Easly to add a second control point
Automated Sensor diagnostics
Front panel Reset button
This manual describes the functions of the Keypad and Menu System. An explanation of the
Error odes including the cause and possible remedy is also included.
See the 7 Quick Install Manual for wiring and initial setup of the distributor.
EDI CONTROL 7
OPERATORS MANUAL

SCHLAGEL, INC.
EDI Distributor Control 7
Page 2 of 2
Key Pad Layout
1
Performes a re-boot of the C7 control.
2
Allows access to the menu of special functions to customize the display or perform special
operations. Use repeted presses on this key to scroll through the Menu system. Access the
function with the number shown.
3
hows a list of all of the named positions of the distributor and the access number (and F-Key
if set) used to move to that position. A valuable function to eliminate using a crossover chart.
Use repeted presses on this key to scroll through the directory, 4 positions at a time.
4
Power on LED.
5
A steady blue LED confirming the spout is in position and there are no errors. This LED will
blink rapidly if certain errors occur.
6
ix speed dial keys (F1 – F6) can be set to access any position with a single key press.
7
The ESCAPE key is used to erase any missed-typed numbers when attempting to move to
another position. It also is used to abandon a Menu operation.
8
Used to allow alphetical characters to be typed in the Menu system when assigning names to
a position. A single SHIFT press will use the upper left character shown on a key and a double
press will use the upper right character.
9
LEDs showing the current status of the sensors on the distributor.

SCHLAGEL, INC.
EDI Distributor Control
7
Page 3 of 3
MENU SYSTEM*
CUSTOMIZE DISPLAY
1
Edit Access
Numbers
Change the number used to access a position. (Numbers 1 – 255 are allowed.)
Access keys by default are 1 through the number of ducts on the distributor. Use
this if you would prefer to use a number with a special meaning.
2
Edit Position
Names
1,2
Rename each spout position, e.g., PO ITION 5 to WET CORN BIN.
3
Edit Function
Keys
1
Assign a peed Dial key (F1-F6) to frequently used positions.
4
Edit Caption
2
Change the name of the distributor as displayed on the top line.
MISC SETTIN S
1
Network
Functions
For network automation. tart/stop and assign name.
2
AutoRun
Testing
Used by technicians for proof of operation.
3
AutoTune
Routine
Used by technicians to reset spout-centering values.
INSTALL/SETUP
1
Run Motor
Manually
Used by technicians to check motor and spout movement.
2
Check ensors Used by technicians to check wiring and condition of the sensors..
3
Auto Install
Distributor
Used by technicians to configure the C7 to the distributor.
Notes
haded routines affect the operation of the distributor and should only be used by those familiar with
the results of its use.
1
These names are shown when using the SPOUT DIRECTORY.
2
Alphabetic characters require the use of the SHIFT key. Use a single or double shift to access the
left or right character of the key respectivally.
*Only the INSTALL/SETUP menu is available at boot.

SCHLAGEL, INC.
EDI Distributor Control 7
Page 4 of 4
ERROR MESSA ES
The C7 control continuously monitors the distributor for abnormal behavior and will notify the
operator when a detectable error occurs. The notification is displayed on Line 2 of the display.
Optional audible or visual alarms are available. Connected PLCs or other automation equipment
are also notified of the error.
Error Msg Reason Cause & Remedy
DRIVE
ERROR
The control has attempted to
move the spout but has not
received any feedback that it
is moving. If it does not
receive feedback for 10
seconds, the control will turn
off the motor and display this
error message.
The spout is jammed, the clutch is
slipping or the sensor circuit is not
functioning.
This is a fatal error. Press Enter to
reset the control. This is almost
always a mechanical obstruction at
the distributor.
POSITIONING
ERR
When the control was
positioning the spout over a
duct, it was not able to set it
to the exact predetermined
position.
omething has electrically or
mechanically disturbed the spout
position over the duct.
The alarms are set and operator
notified. Try accessing this position
again. Repeated errors indicate
action is required to repair the
problem. Check for a loose clutch or
loose drive chains in the drive
assembly.
SPO T
MOVED
This error message indicates
that the spout has been
moved out of position after a
successful stop. The C7
Control continuously monitor
spout position and raise this
alarm if the spout moves out
of position.
omething has electrically or
mechanically disturbed the spout
position over the duct.
This is a fatal error. Press Enter and
the control will return to the reset
screen. Check for a loose clutch or
loose bolts on the drive wheel or
drive arm assemblies.
SENSOR
ERROR
While the control is moving
the spout it continuously
anticipates the next code it
will encounter. If the next
code does not match the
anticipated code, the control
will attempt to re-read it up to
3 times. If it fails on the 3rd
try, the control will issue this
error.
An improperly positioned sensor
block in the distributor usually
causes this error.
This is a fatal error. Press Enter and
the control will return to the reset
screen. Position and shim the sensor
block properly. Run the Check
ensors routine.