Saunders M-VUE Instrucciones de instalación y funcionamiento

Installation, Operation and
Maintenance Manual
Saunders® M-VUE
Intelligent Sensing Technology
brands you trust.
www.cranecpe.comCrane ChemPharma & Energy

2www.cranecpe.com
Crane ChemPharma & Energy
Table of Contents
Basic Saftey Instructions...............................................................................................................................................4
Scope of Supply ...............................................................................................................................................................5
Overview ..............................................................................................................................................................................6
Basic Installation Guide...........................................................................................................................................7-11
Mounting the Solenoid Valve.......................................................................................................................9
Mounting M-VUE to an Actuator............................................................................................................. 10
Solenoid Valve Pneumatic Connections..............................................................................................11
Calibration....................................................................................................................................................................12-16
Integral Solenoid ................................................................................................................................................13
Remote Solenoid............................................................................................................................................... 14
AS-Interface...........................................................................................................................................................15
DeviceNet ............................................................................................................................................................... 16

3
www.cranecpe.com Crane ChemPharma & Energy
Table of Contents
Point-to-Point Wiring....................................................................................................................................................17
AS-Interface (AS-i) ..................................................................................................................................................18-20
Wiring....................................................................................................................................................................... 18
Communication Bits.........................................................................................................................................19
Addressing ............................................................................................................................................................ 20
DeviceNet.....................................................................................................................................................................21-25
Wiring.......................................................................................................................................................................23
Communication Bytes ................................................................................................................................... 24
Setting Address on DeviceNet Units Only......................................................................................... 25
Using the M-VUE Menus .................................................................................................................................... 26-28
Technical Data ................................................................................................................................................................. 29
Troubleshooting: Alarms...........................................................................................................................................30
Dimensions........................................................................................................................................................................ 31

4www.cranecpe.com
Crane ChemPharma & Energy
Basic Safety Instructions
These instructions do not make allowance for:
• Contingencies and events which may arise during the installation, operation, and maintenance of the sensor.
• Local safety regulations; the operator is responsible for observing these regulations, also with reference to the installation
personnel.
High Pressure
Before removing pneumatic lines and valves, turn off the pressure and vent the lines. To prevent damage, make sure that all the
pneumatics connections are made correctly.
Electrical Risks
Before working on the sensor, switch off the power supply and prevent reactivation. Observe applicable accident prevention and
safety regulations for electrical equipment.
Hazardous Situation
To avoid injury, ensure:
• That the system cannot be activated unintentionally.
• Installation and maintenance may be carried out by authorized technicians only.
• After an interruption in the power or pneumatic supply, ensure that the process will be restarted in a defined and controlled
manner.
• The sensor must be operated according to the operating instructions
Warning:
Do not connect or disconnect while circuit is live unless location is known to be non-hazardous.

5
www.cranecpe.com Crane ChemPharma & Energy
Scope of Supply
A full range of additional accessories and spares are available from Saunders® on request.
Please contact us for more information
Sensor Electronics Module Magnetic Target with
visual indicator
Exhaust Block
(optional)
Solenoid Cover
(optional)
Cable
(optional)
Sensor Mounting Base
3/2 Integral Solenoid (optional)Spare Magnetic Key

6www.cranecpe.com
Crane ChemPharma & Energy
Overview
Magnetic key for use with H1
and H2 magnetic buttons
Mechanical position
indicator
Optional
solenoid
valve
Magnetic Buttons
H1 and H2 to allow
configuration with
the magnetic key
Magnetic button
connection indication
Ring of super
bright LEDs
(Indicate valve
position)

7
www.cranecpe.com Crane ChemPharma & Energy
Basic Installation Guide
Sensor Electronic Module
Cable connector
(Available in various types, contact
Saunders® for further information.)
Sensor Mounting Base

8www.cranecpe.com
Crane ChemPharma & Energy
Basic Installation Guide
PRODUCT TYPE COMMUNICATION TYPE CONNECTION TYPE SOLENOID TYPE OPTIONAL EXHAUST
M-VUE = M-VUE
2E2 = Point to Point V15= M12 5-Pin + SC = No Solenoid +E = Exhaust with 1/8” NPT
ASI 3.1 = ASi v2.0 Profile 70 V1 = M12 4-Pin + BM-V = 1/8” NPT +ES= Exhaust with 1/8” BSP
ASI 3.1A = ASi v2.0 Profile 7H + BM-VS = 1/8” BSP
ASI 3.2 = ASi v2.1
ASI 3.3 = ASi v 3.0
DNC = DeviceNet VM = 7/8” 5-Pin
V15= M12 5-Pin
EXAMPLE: M-VUE-DNC-VM + BM-V + E
MEANING: M-VUE Sensor with DeviceNet, 7/8” 5 Pin connector, 1/8” NPT Solenoid Valve and 1/8” Exhaust NPT Block
Note: Configurations are dependent upon communication type, network protocol etc. Contact Saunders® for more information
Check that the M-VUE
model number is correct for
the application

9
www.cranecpe.com Crane ChemPharma & Energy
Basic Installation Guide Mounting the Solenoid Valve
ORINGS
Remove the plastic solenoid cover
by loosening the two screws that
secure it to the pneumatic body.
Insert the electrical connector from
the sensor into the larger orifice of
the pneumatic case.
Remove the two screws securing
the coil and pull the entire
assembly out.
Attach the pneumatic case to the
electronics module with the four
fastening screws provided.
Make sure the two O-rings are
attached to the side of pneumatic
case. (This will avoid contamination
and any air leakage.)
Re-attach the coil to the pneumatic case
and tighten the two fastening screws.
Connect the two cables (electronic
sensor and the coil). Replace the
solenoid cover and tighten the screws
Tools Required:
• Philips or Flat head screwdriver 8 mm open ended spanner to suit air fittings.
• Low strength threadlock adhesive (recommended)
• Thread sealing compound for pneumatic fittings (if required)
Note: For actuators that require a mounting kit. Please contact Saunders for the relevant
installation procedure

10 www.cranecpe.com
Crane ChemPharma & Energy
Basic Installation Guide Mounting M-VUE to an Actuator
Loosen the three captive screws
from the electronics module and
undock the mounting base
Re-attach sensor electronics
module to the sensor
mounting base. At this
point verify the mechanical
indicator displays the correct
position
Install the enclosed O-ring to the
mounting base and attach it to the
top of the actuator. The plate will fit
directly to Saunders actuators with
a separation of 35mm at the top.
Other actuators or distances will
require an additional adapter plate.
The yellow indicator should be
fully visible when the aseptic valve
is OPEN. If additional adjustments
are necessary adjust the height of
the yellow indicator knob until the
OPEN position is visible.
Screw fix the Magnetic Target with
Visual Indication to the actuator.
We recommend any low strength
threadlock adhesive.
After adjustments have been
completed tighten the three captive
screws at the base of the sensor
Connect any air fittings and tube to
the actuator(and M-VUE solenoid if
integral solenoid is fitted)
Note: Supply pressure not to exceed 8 bar (116 PSI)
Once power supply is provided to
M-VUE, it will perform self-check
to indicate valve position. After self
check the LEDs indicate the valve
position and factory settings for
the sensor are unchanged.
Optional Exhaust Port Block
M-VUE can be equipped with an optional
exhaust block if air used by pneumatic
actuator needs to be ported out of a
classified area.
Make sure the O-ring provided with the block
is installed correctly between the pneumatic
case and the exhaust block in order to avoid
any air leakage. Use the three enclosed screws
to secure the block to the case.
35 mm
xx mm
Valve
Sensor
Tabla de contenidos
Otros manuales de Accesorios de Saunders