Contents
PREPARATION 3
Safety precautions 3
CHECKING BEFORE THE INSTALLATION 7
Checking before the installation 7
Accessories 7
Net dimension 7
Name of the parts 8
Diagram of DMS 2.5 and DVM CHILLER & FCU 9
Diagram of BMS and DVM CHILLER & FCU 10
INSTALLATION 12
FCU KIT installation 12
FCU KIT installation 12
Wiring work 15
Functions of FCU KIT 19
Diagram of ASS'Y control 21
Installing water temperature sensor 26
SETTING 28
Setting address of FCU KIT and installation option 28
Procedure of option setting 28
Setting an option 29
Setting address (MAIN/RMC) of FCU KIT 34
Setting FCU KIT installation option 35
Changing a particular option 43
OTHERS 44
Troubleshooting 44
Error code 44
Inspection and test operation 45
Checking FCU KIT installation 45
Trial operation 45
Function of wired remote controller 47
Display 47

3
PREPARATION
These safety precautions are for owner’s safety and preventions of property damage.
Therefore, please read this manual thoroughly before installing or using your product.
(Please refer to appropriate installation for any optional product installation.)
WARNING
Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor personal injury or property damage.
Follow directions.
Do NOT attempt.
Make sure the machine is grounded to prevent electric shock.
Unplug the power plug from the wall socket.
Do NOT disassemble.
For installation
WARNING
The installation of this product must be performed by a qualied technician or service
company.
yFailure to do so may result in electric shock, re, product malfunction, or injury.
Connect the power with rated voltage when installing.
yFailure to do so may result in electric shock, re, or product malfunction.
Check if the installation was done correctly according to the installation manual.
yThere is risk of electric shock or re if the product is installed incorrectly.
Make sure that all wiring work is done by qualied person complying regional
standards and instructions in this manual.
yIf the installation is done by unqualied person, there is risk of product malfunction,
electric shock or re caused by incorrect installation.
Contact the service center when you need to dispose the product.
Safety precautions

4
PREPARATION
Do not install this product near a heater, inammable material. Do not install this
product in a humid, oily or dusty location, in a location exposed to direct sunlight and
water (rain drops). Do not install this product in a location where gas may leak.
yPotential risk of electric shock or re.
Do not attempt to move or re-install the product that is already installed.
yThere is risk of electric shock or re.
Do not attempt to repair, disassemble, or modify the product yourself.
yThere is risk of product damage, electric shock or re. When repair is needed,
consult service center.
For installation
CAUTION
Install the product on a hard and even place that can support its weight.
yIf the place cannot support its weight, the product may fall down and it may cause
product damage.
Make sure there is no tension to the cable during installation.
yCable may get cut and cause re.
Install the product in a place with temperature between 0~39°C (32~102°F) with
no direct sunlight.
yIf not, there is risk of re or product malfunction.
Do not install the product in a place where special spray or acid/alkali solution is used.
yIf not, there is risk of re or product malfunction.
Do not connect the power cable to the communication cable terminal.
yThere is risk of re.
When installing the product in hospitals or other places, make sure that the product
does not interrupt with other products.
yIf not, there is risk of product malfunction.
Do not allow water to enter the product.
yIf not, there is risk of electric shock or re.
Do not press the buttons with any sharp objects.
yThere is risk of electric shock or damage to the parts.
Safety precautions

5
PREPARATION
For power supply
WARNING
Do not pull or excessively bend the power cord. Do not twist or tie the power cord.
yPotential risk of electric shock or re.
For operation
WARNING
If the product generates a strange noise, a burning smell or smoke, disconnect the
power supply immediately and contact a service center.
yPotential risk of electric shock or re.
Contact a service center to reinstall the product.
yIf not, there is risk of product malfunction, water leakage, electric shock or re.
yA delivery service for the product is not provided. If you reinstall the product in
another location, additional construction costs and installation fee will be charged.
When an error appears or the product malfunctions, stop the operation immediately.
yIf the product generates a burning smell or it malfunctions, turn it off and disconnect
the power supply immediately, and then contact a service center. If not, there is risk
of electric shock, re, or damage to the product.
Do not attempt to repair, disassemble, or modify the product yourself.
yThis may result in electric shock, re, a product malfunction or injury.
For operation
CAUTION
Do not allow water to enter the product.
yThere is risk of re or explosion.

6
PREPARATION
Do not operate the product with wet hands.
yThere is risk of electric shock.
Do not spray volatile material such as insecticide onto the product.
yAs well as being harmful to humans, this may also result in electric shock, re or a
product malfunction.
Do not hit or apply excessive force of any kind to the product.
Do not use this product for other purposes.
yThis product is designed to be used only for DVM CHILLER.
Do not press the buttons with any sharp objects.
yElectric shock or part damage may occur.
For cleaning
WARNING
Do not clean the product by spraying water directly onto it. Do not use benzene,
thinner, acetone or alcohol to clean the product.
yThis may result in discoloration, deformation, damage, electric shock or re.
Safety precautions

7
CHECKING BEFORE THE INSTALLATION
Checking before the installation
Accessories
Name Pipe temperature sensor
[10 m(32.8 ft)] Aluminum tape Rubber tape M4x16 screws
Quantity 2424
Image
Name Insulator Cable tie
Wired Remote Controller
(Purchased separately)
Quantity 26 1
Image
Net dimension
[Unit : mm(inch)]
200(7.87)
270(10.62)
87(3.42)

8
CHECKING BEFORE THE INSTALLATION
Name of the parts
Upper cover
FCU KIT PBA
Lower base
Spare holes
Checking before the installation

9
CHECKING BEFORE THE INSTALLATION
Diagram of DMS 2.5 and DVM CHILLER & FCU
CN4
CN3
RED
CN2
BLK
YEL
RED
Y-GRN
CN4
CN3
RED
CN2
BLK
YEL
RED
Y-GRN
DMS2.5 (MIM-D01AN)
Connect up to 16 FCU interface modules
R1,R2
Module
controller
(MCM-A00N)
Wired remote
controller
F3,F4
F3,F4
F1,F2
FCU KIT
(MIM-F00N)
FCU FCU
Connect up to 16 FCU KITs
DVM CHILLER
yFCU KIT and FCU interface module is for integrated control of FCU with DVM CHILLER by
DMS 2.5.
yMaximum number of FCU interface modules that can be installed to a DMS2.5, and
maximum number of FCU KITs that can be installed to a FCU interface module is both 16.
yMaximum number of FCU interface modules that can be installed to a channel of DMS2.5
is 16 (Max. 128 FCU KITs).
ySome functions of wired remote controller may not work. (Refer to page 47.)
yControl logic of DMS2.5 should be set to interlock FCU KIT and DVM CHILLER. Refer to
user manual of DMS2.5 for setting control logic.

10
CHECKING BEFORE THE INSTALLATION
Checking before the installation
yFCU interface module should be installed inside of FCU KIT.
yDMS2.0 is not supported.
yCabel Max length
– DMS -FCU interface module : max 1000 m(3280.8 ft)
– FCU interface module -FCU KIT :max 1000 m(3280.8 ft)
CAUTION
• Install FCU that has terminal block to x power cable by screw. Do not connect power
cable by cutting.
Diagram of BMS and DVM CHILLER & FCU
Connect up to 16 FCU interface modules
CN4
CN3
RED
CN2
BLK
YEL
RED
Y-GRN
BMS (for Buildings)
BACnet Gateway (MIM-B17BN) /
LonWorks Gateway (MIM-B18BN)
Module
controller
(MCM-A00N)
Wired remote controller
FCU KIT
(MIM-F00N)
DVM CHILLER
Connect up to 16 FCU KITs
FCU FCU
F3,F4 F3,F4
F1,F2
R1,R2 R1,R2
Otros manuales para DVM
1
Tabla de contenidos
Otros manuales de Enfriador de Samsung

Samsung
Samsung AG042KSVANH Manual de usuario

Samsung
Samsung AGTN1DKH Series Manual de usuario

Samsung
Samsung DVM Chiller Guía de instalación

Samsung
Samsung AG010KSV Series Manual de usuario

Samsung
Samsung DVM Manual de usuario

Samsung
Samsung MCM-A00UN Manual de usuario

Samsung
Samsung AG042KSV Series Manual de usuario