S/C Black BLK-IPE101 Manual de usuario

H.264 Network Video Encoder
User Manual
Product: BLK-IPE101
Please read this manual before using your encoder, and always follow the
instructions for safety and proper use. Save this manual for future reference.
BLK-IPE101_PM
®

ii www.sc-black.com
WARNING
RISK OF ELECTRIC SHOCK. DO NOT OPEN.
To reduce the risk of electric shock, do not
remove cover (or back). No user serviceable
parts inside. Refer servicing to qualied
service personnel.
CAUTION
Operate this encoder only in environments where the temperature or humidity is within
the recommended range. Operation in extreme temperatures or humidity levels may cause
electric shock and shorten the life of the product.
LEGAL NOTICE
SC Black is a registered trademark of Supercircuits, Inc.
Supercircuits products are designed to meet safety and performance standards with the use of specic
Supercircuits authorized accessories. Supercircuits disclaims liability associated with the use of non-
Supercircuits authorized accessories.
The recording, transmission, or broadcast of any person’s voice without their consent or a court order is
strictly prohibited by law.
Supercircuits makes no representations concerning the legality of certain product applications such as
the making, transmission, or recording of video and/or audio signals of others without their knowledge
and/or consent. We encourage you to check and comply with all applicable local, state, and federal laws
and regulations before engaging in any form of surveillance or any transmission of radio frequencies.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Supercircuits, Inc. disclaims any proprietary interest in
trademarks and trade names other than its own.
No part of this document may be reproduced or distributed in any form or by any means without the
express written permission of Supercircuits, Inc.
© 2010 Supercircuits, Inc. All rights reserved.
11000 N. Mopac Expressway, Building 300, Austin, TX 78759
Sales/Support: 1.800.335.9777 | Fax: 1.866.267.9777

1H.264 Network Video Encoder
Table of Contents
SECTION 1 Features .......................................................2
1.1 Front panel indicators and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Back panel connectors ........................................4
SECTION 2 Installation and Setup ............................................5
2.1 What’s in the box ............................................5
2.2 Tools you need ..............................................5
2.3 Find an IP address for your encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 Check LAN for default IP address compatibility . . . . . . . . . . . . . . . . . . . . . 8
2.5 Install IPAdmin Tool ..........................................9
2.6 Install the encoder ..........................................10
2.7 Connections ...............................................10
2.8 Configure the encoder IP address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.9 Setup the encoder Basic Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.10 Final installation checks ......................................23
2.11 Cleaning ..................................................25
SECTION 3 Specifications ..................................................26
APPENDIX A Troubleshooting ................................................28
A.1 Reboot encoder ............................................28
A.2 Set encoder to factory default network settings . . . . . . . . . . . . . . . . . . . . 28
A.3 Check firmware version ......................................29
A.4 Support ..................................................29
APPENDIX B Dimensions ...................................................30
APPENDIX C Power over Ethernet .............................................31
C.1 PoE compatibility ...........................................31
C.2 Power classification .........................................31

2www.sc-black.com
SECTION 1: FEATURES
SECTION 1
Features
The SCBlack BLK-IPE101 is a professional, premium-grade, state-of-the-art encoder designed for indoor
installation in networks where exceptional video and audio quality is required with minimal bandwidth and
storage available. Features include:
• H.264, MPEG-4, and MJPEG real-time encoding at D1
• RTP/RTSP and unicast/multicast support
• Dual streaming mode with different codec/resolution/bit rate
• De-interlacing on DSP
• Loop-out video for external monitors
• Two ways audio
• RS-485/422 serial port for Pan/Tilt/Zoom
• RS-232C serial port for POS terminal
• Motion detection by hardware
• On Screen Display (OSD) by hardware
• Power over Ethernet (PoE) support
• Video Content Analysis Presence, Surveillance (optional)
• RTSP and HTTP-API for application development available
BLK-IPE101 encoder front panel

3H.264 Network Video Encoder
SECTION 1: FEATURES
1.1 Front panel indicators and connectors
Table 1. Status and Data LEDs indications
Status Data Item
OFF OFF Power OFF
System initialization
Off Blinking Dark Orange In Process
Orange Off Normal State
Orange Dark Orange Abnormal State
Kernel booting up
Orange Green In Process
Orange Off Normal State
Orange Green Abnormal State
Video streaming service
Blinking Green Off Normal
Green Off Abnormal
DSP operation status
Orange blinks at every 1 second Off Normal
Orange blinks at every 1 second Red High Overload
Vin Video input BNC connector
SD Slot for SD type memory card; for external storage
Vout For loop out of video input

4www.sc-black.com
1.2 Back panel connectors
BLK-IPE101 encoder back panel
USB Connect to a USB device (or USB hub) for external storage.
Ethernet RJ-45 LAN connector for 10/100Base-T Ethernet. This connector accommodates PoE.
Pin block Terminal for audio output/input, alarm out, sensor in, and RS-232/RS-485 serial devices
Reset Reset switch for restarting the encoder, or resetting the encoder to factory default settings.
DC12V Power adapter connector.
SECTION 1: FEATURES

5H.264 Network Video Encoder
SECTION 2: INSTALLATION AND SETUP
SECTION 2
Installation and Setup
2.1 What’s in the box
Your encoder includes the following:
• BLK-IPE101 encoder
• 12 V DC power adapter
• 9-pin terminal blocks (2)
• Hardware installation kit including mounting brackets (2), screws (4), and wall inserts (2)
• CD mini disk with application software, software manual, and encoder manual (this document)
2.2 Tools you need
To install the encoder, you will need:
• Phillips #2 screwdriver
• Drill 1/4” drill bit
• PC with Microsoft® Windows® XP SP3 or newer
2.3 Find an IP address for your encoder
Devices attached to an Local Area Network (LAN) are each assigned unique address (IP address) that
they use when sending messages with each other. No two devices on a single Ethernet network can have
the same IP address. Otherwise, conicts will occur.
Your IP encoder is pre-congured with a static IP address, subnet mask, and gateway setting:
IP address: 192.168.0.100
Subnet mask: 255.255.255.0
Gateway: 192.168.0.1
Usually these settings are changed during installation to ones more compliant with the network
conguration.
Use the following procedure to determine a compliant IP address to assign to your encoder. If connecting
your encoder to a large enterprise network, consult with your network administrator before attaching the

6www.sc-black.com
SECTION 2: INSTALLATION AND SETUP
encoder to the LAN for network settings to ensure that your encoder won’t initially conict with other
devices. Your network administrator should also setup WAN (Internet) access to the encoder.
If you encounter a problem and need to contact Supercircuits Support, rst complete the chart in step 1
about your Computer (PC) and encoder network settings, if possible. Support will need this information to
provide assistance.
1. At a PC attached to the same LAN that will be shared with your encoder, determine the IP address,
subnet mask, and default gateway of your PC and record it in Table 1. To nd this information, do
the following at the Windows desktop:
a. Hold down the Windows key and press r (without the quotes) to open the Run dialog box.
b. Type cmd in the entry eld and click OK to open the DOS command window.
c. At the command prompt, enter ipcong. The PC will display Ethernet data associated with
your Ethernet adapter LAN connection.
Example: Typical use of ipcong in Windows XP
d. Enter the IP Address, Subnet Mask, and Default Gateway for your PC’s Ethernet adapter into
Table 2.

7H.264 Network Video Encoder
SECTION 2: INSTALLATION AND SETUP
NOTE
The Ethernet adapter data you see by using ipcong will probably be different from that
shown in the example above. If you are using Windows Vista or Windows 7, the IP address
is identied as the “IPv4 Address.”
Table 2. PC/Encoder network settings
Computer (PC) Encoder
IP Address
Subnet Mask
Default Gateway
CAUTION
If connecting your encoder to an enterprise network, consult with your network
administrator for the encoder IP address, subnet mask, and default gateway.
2. At your PC, nd an IP address on your network that is not in use:
a. Write down the EXACT IP address of your PC up to the third/last period. Using the example
shown above, this expression is: 192.168.1.
b. After the third period, include any number between 1 and 256 that is different from the one
in your PC’s IP address, 168. As a rst try, let’s choose 200, which will form the IP address
192.168.1.200.
c. Next, use the ping command in the DOS window to see if this IP address is in use on your
network. The format of the ping command is:
ping <IP address>
To test this IP address, enter ping 192.168.1.200. Any reply received from the ping indicates
that a device on the network is already using this IP address and you can connect to it.

8www.sc-black.com
SECTION 2: INSTALLATION AND SETUP
In the example shown above, the message “Reply from 192.168.1.200: ...” indicates that your
PC can reach the device with that IP address, and that address is in use.
d. Since the ping test of the IP address we tried showed the address was in use, try another
number between 1 and 256. For example, let’s ping 192.168.1.201. At the DOS prompt,
enter: ping 192.168.1.201
e. In this test, the message “Request timed out” indicates that your PC cannot reach the device
with that IP address, and that address is probably not in use. Enter this number into Table 1. If
this test indicated that this IP address is in use, try other IP addresses using the steps above
until an unused address is found.
2.4 Check LAN for default IP address compatibility
Because all SC Black cameras and encoders are factory congured with the static IP address
192.168.0.100, check the LAN before connecting your encoder to ensure that network conicts won’t
occur.