RuggedCom RUGGED VDSL RS910L Manual de usuario

RuggedCom Inc. I30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4
Tel: (905) 856-5288 I Fax: (905) 856-1995 IToll Free: (888) 264-0006
Rugged
RuggedRugged
RuggedVDSL
VDSLVDSL
VDSL
RS9
RS9RS9
RS91
11
10
00
0L
LL
L
Serial and Ethernet Device Server with Ethernet over VDSL
Uplink
Installation Guide
www.ruggedcom.com

2
2007 RuggedCom Inc. All rights reserved Rev100
Federal Communications Commission
Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications
Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his expense
Trademarks:
Ethernet is a trademark of Xerox Corporation
RuggedSwitch, RuggedRated, ROS and eRSTP are trademarks of RuggedCom® Inc
Caution
This product contains a laser system and is classified as a “CLASS 1 LASER PRODUCT”
Use of controls or adjustments or performance of procedures other than those specified herein
may result in hazardous radiation exposure This product contains no user serviceable parts
Attempted service by unauthorized personnel shall render all warranties null and void
Should this device require service see the “Warranty” section of this installation guide
Important
This unit should be installed in a restricted access location where access can only be gained by
service personnel or users who have been instructed about the reasons for the restrictions
applied to the location and about any precautions that shall be taken; and access is through the
use of a tool or lock and key, or other means of security, and is controlled by the authority
responsible for the location

3
2007 RuggedCom Inc. All rights reserved Rev100
Table of Contents
1Product Overview ............................................................................................................................... 5
1.1 Functional Overview ................................................................................................................... 5
1.2 Feature Highlights ...................................................................................................................... 5
1.3 RS910L Front Panel Description ................................................................................................ 6
1.4 RS910L Bottom Panel Description.............................................................................................. 7
2Installation........................................................................................................................................... 8
2.1 Din Rail Mounting....................................................................................................................... 8
2.2 Power Supply Wiring and Grounding ......................................................................................... 9
2.3 Failsafe Output Wiring.............................................................................................................. 12
2.4 RS232 Console Port Wiring ...................................................................................................... 13
3Serial Ports ........................................................................................................................................ 14
4Ethernet Ports ................................................................................................................................... 18
4.1 RJ11 Ethernet over VDSL Port ................................................................................................. 18
4.2 RJ45 Ethernet Ports .................................................................................................................. 20
4.3 Fiber Optic Ethernet Ports........................................................................................................ 21
4.4 Ethernet Panel Description ....................................................................................................... 22
5Technical Specifications ................................................................................................................... 23
5.1 Operating Environment............................................................................................................. 23
5.2 Power Supply Specifications ..................................................................................................... 23
5.3 Failsafe Relay Specifications .................................................................................................... 23
5.4 RJ11 Ethernet over VDSL Port Specifications .......................................................................... 24
5.5 Serial Ports................................................................................................................................ 24
5.6 Ethernet Ports............................................................................................................................ 25
5.7 Communication Standards ........................................................................................................ 25
5.8 Mechanical Specifications......................................................................................................... 26
6Type Tests.......................................................................................................................................... 27
6.1 IEC 61850-3 Type Tests ............................................................................................................ 27
6.2 IEEE 1613 Type Tests ............................................................................................................... 28
6.3 IEC Environmental Type Tests.................................................................................................. 28
7Warranty ........................................................................................................................................... 29

4
2007 RuggedCom Inc. All rights reserved Rev100
Table of Figures
Figure 1 - RS910L Front Panel Description............................................................................................... 6
Figure 2 - RS910L Bottom Panel Description ............................................................................................ 7
Figure 3 - RS910L DIN Rail Mounting....................................................................................................... 8
Figure 4 - RS910L Power Supply Inputs.................................................................................................... 9
Figure 5 - DC Power supply wiring and grounding diagram ................................................................. 10
Figure 6 - Dielectric Strength Testing....................................................................................................... 11
Figure 7 - RS910L Failsafe Output Relay ................................................................................................ 12
Figure 8 - RS232 Female DCE pin-out ..................................................................................................... 13
Figure 9: Fiber Serial Interface (ST Connector) ..................................................................................... 14
Figure 10: DB9 Port pin-out...................................................................................................................... 15
Figure 11: RJ45 Port pin-out..................................................................................................................... 16
Figure 12: Conceptual recommended RS485 wiring diagram ............................................................... 17
Figure 13 - RJ11 port pin-out and LEDs.................................................................................................. 18
Figure 14 - RJ45 Ethernet port pin-out.................................................................................................... 20
Figure 15: 10FL ST connector.................................................................................................................. 21
Figure 16: 100FX MTRJ connector ......................................................................................................... 21
Figure 17: 100FX ST connector ............................................................................................................... 21
Figure 18: 100FX LC connector............................................................................................................... 22
Figure 19: 100FX SC connector ............................................................................................................... 22
Figure 20: Ethernet panel LED description ............................................................................................ 22
Figure 21 - Mechanical Specifications ...................................................................................................... 26
Table of Tables
Table 1 - Status LEDs................................................................................................................................... 6
Table 2 - RJ11 port pin-out ....................................................................................................................... 18
Table 3 - RJ11 port LED description........................................................................................................ 18
Table 4 - Typical Performance on 24 AWG PIC twisted-pair................................................................ 19
Table 5 - RJ45 Ethernet port pin-out ....................................................................................................... 21
Table 6 - Operating Environment............................................................................................................. 23
Table 7 - Power Supply Specifications...................................................................................................... 23
Table 8 - Failsafe Relay Specifications...................................................................................................... 23
Table 9 – RJ1 Ethernet over VDSL Port Specifications ......................................................................... 24
Table 10: Copper Port Specification......................................................................................................... 24
Table 11: Fiber Optic Port Specification.................................................................................................. 24
Table 12: Ethernet Ports - Copper Specifications ................................................................................... 25
Table 13: Ethernet Ports – Fiber Optic Specifications........................................................................... 25
Table 14 - Communication Standard Compliance .................................................................................. 25
Table 15 - Mechanical Specifications........................................................................................................ 26
Table 16 - IEC 61850-3 Type Tests ........................................................................................................... 27
Table 17 - IEEE 1613 Type Tests .............................................................................................................. 28
Table 18 - Environmental Type Tests....................................................................................................... 28

5
2007 RuggedCom Inc. All rights reserved Rev100
1 Product Overview
1.1 Functional Overview
The RuggedVDSLTM RS910L is an industrial hardened serial server and managed Ethernet switch
su orting Ethernet over VDSL (EoVDSL). The RS910L can be configured with 2 serial orts
(RS485/RS422/RS232/fiber) and/or 2 Ethernet orts (co er or fiber). The RS910L can
interconnect multi le ty es of intelligent electronic devices (IEDs) that have different methods of
communications. The EoVDSL ort allows for aggregation of these devices at a remote location
back to the central control room using existing tele hone grade cable (or other legacy serial
cabling). The EoVDSL u link allows u to 4km LAN segments at u to 50 Mb s.
1.2 Feature Highlights
•Interface Ports
o1 Ethernet over VDSL (EoVDSL) interface
o2 Serial and/or 2 Fast Ethernet Ports
oRS485/RS422/RS232 Serial Ports (DB9 and RJ45)
oSerial Fiber Interface (ST) available
o10/100BaseTX or 100BasesFX Ethernet orts
•Ethernet Over VDSL Port Characteristics:
oU to 4 km LAN segments
oSymmetric data rates u to 50 Mb s
oAutomatically selects fastest data rate based on distance and quality of cable
oSoftware selectable to be master or slave
oFrequency Division Multi lexing (FDM)

6
2007 RuggedCom Inc. All rights reserved Rev100
1.3 RS910L Front Panel Description
Failsafe Relay Power Port
Ports 1 & 2
RS485/422/232
Serial
Or
Serial over Fiber
Ports 3 & 4
10/100Base-T
or
100Base-F
Or
10Base-FL
Port 9
Ethernet over VDSL
Power & Alarm
Figure 1 - RS91 L Front Panel Description
Status LED Colour Activity Comments
Power LED Green Solid Power On
Alarm LED Red Solid Alarm condition exists
Table 1 - Status LEDs

7
2007 RuggedCom Inc. All rights reserved Rev100
1.4 RS910L Bottom Panel Description
Failsafe Relay
Console Port
Power
Port
Chassis
Ground
Optional Din-Rail
Mounting Bracket
Figure 2 - RS91 L Bottom Panel Description

8
2007 RuggedCom Inc. All rights reserved Rev100
2 Installation
2.1 Din Rail Mounting
An o tional DIN rail mounting bracket is available for the RS910L. The figure below details
mounting instructions for the standard 1” DIN Rail.
Figure 3 - RS91 L DIN Rail Mounting

9
2007 RuggedCom Inc. All rights reserved Rev100
2.2 Power Supply Wiring and Grounding
2.2.1 AC Power Supply Wiring and Grounding
Figure 4 - RS91 L Power Supply Inputs
The RS910L AC ower su ly in uts should be connected as follows:
1. +/L should be connected to AC Line/Hot.
2. -/N should be connected to AC Neutral.
3. Surge Ground should be connected to the Chassis Ground via a braided cable or other
a ro riate grounding wire. Surge Ground is used as the ground conductor for all surge
and transient su ression circuitry internal to the unit.
4. Chassis Ground must be connected to the AC ground terminal.
NOTES:
1. Equi ment must be installed according to the a licable country wiring codes.
2. All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases
where users require the in uts to be isolated from ground, remove the ground braid
between Surge and Chassis Ground. Note that all line-to-ground transient rotection
circuitry will be disabled.

10
2007 RuggedCom Inc. All rights reserved Rev100
2.2.2 DC Power Supply Wiring and Grounding
Figure 5 - DC Power supply wiring and grounding diagram
The RS910L low voltage DC ower su ly features reverse olarity rotection and dual
inde endent in uts. The latter feature allows the connection of two DC sources with the same
nominal voltage to rovide redundant ower su ly in uts.
The RS910L DC ower su ly in uts should be connected as follows:
1. Connect to the DC in uts according to the olarity markings on the unit.
2. Surge Ground should be connected to the Chassis Ground via a braided cable or other
a ro riate grounding wire. Surge Ground is used as the ground conductor for all surge
and transient su ression circuitry internal to the unit.
3. Chassis Ground must be connected to the rotective earth.
NOTES:
1. Equi ment must be installed according to the a licable country wiring codes.
2. All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases
where users require the in uts to be isolated from ground, remove the ground braid
between Surge and Chassis Ground. Note that all line-to-ground transient rotection
circuitry will be disabled.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Hardware de red de RuggedCom

RuggedCom
RuggedCom RUGGEDMAX WIN7000 Manual de usuario

RuggedCom
RuggedCom RUGGEDBACKBONE RX1510 Manual de usuario

RuggedCom
RuggedCom RuggedMAX WiN7013 Manual de usuario

RuggedCom
RuggedCom RuggedServer RS416 Manual de usuario

RuggedCom
RuggedCom RuggedWireless RS900W Family Manual de instalación y operación
Manuales populares de Hardware de red de otras marcas

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manual de usuario

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manual de usuario

Yudor
Yudor YDS-16 Manual de usuario

D-Link
D-Link ShareCenter DNS-320L Manual de usuario

Samsung
Samsung ES1642dc Instrucciones de uso

Honeywell Home
Honeywell Home LTEM-PV Instrucciones de montaje