Form #: 7.20.533
Rev: 2

3
INTRODUCTION
The RPB® GX4, model 08-400, tests the
quality of compressed breathing air for
Carbon Monoxide and other gases*.
Compressed Air is supplied to the unit
through the sampling hose at a constant
ow to the sensors for continuous
analysis.
KEY FEATURES:
- Multiple gasses monitored
simultaneously
- Traceability of gas levels,
temperature, alarms, air ow,
sensorchecks and more
- Internal web server for remote
monitoring, reviewing logs and
printing reports
- 3 inch LCD display and 6 buttons to
easily navigate the menus
- Exterior lights and alarms
- Auxiliary output for external alarms,
strobe lights or solenoids
- Tamper switch sealed inside of unit
- Robust protective housing
- Mounts to a Radex ltration system
- Optional wall mount bracket
- Optional protective travel case.
The monitor must be supplied with
GradeD air and must be free of oil
and water to prevent contamination
of the sensors. A micro-mist lter prior
to the Radex air ltration system is
recommended to protect the GX4 and
the operator(s). Check with your local
regulatory bodies for more information
on local requirements.
The monitor operates at 12 volts DC and
can be used with either the 110/240v AC
Adaptor (P/N: 08-430) or the 12v cable
with Battery Clips (P/N: 08-431). The unit
is designed to operate in temperature
ranges of 14° to 120F (-10 to +50C)
and Humidity levels of 5% - 99% (no
condensation).
The RPB® GX4 when used with the
Carbon Monoxide Sensor Cartridge (P/N:
08-420-01) satises the requirements of
OSHA rule 29 CFR 1910.134 for carbon
monoxide monitoring.
RPB® Safety provides maintenance
service through its service centers.
In some locations RPB® has units
available for hire while your unit is being
serviced. Contact our Customer Service
Department on 1-866-494-4599 or
email: [email protected]om
* Visit rpbsafety.com for a list of available
gas sensors.
WARRANTY
This RPB® Safety product is covered by
a manufacture’s warranty of 1 year. The
manufacturer warranty covers defects
in material, workmanship and does not
cover damage caused by misuse or abuse.
RPB® Safety’s only obligation and your
exclusive remedy shall be to repair, replace
or refund the purchase price of such
parts or products upon the presentation
of proof of purchase. Maximum liability
is in no case to exceed the value of the
RPB® Safety Product involved. Damage
to the Sensor Cartridges by oil or other
contaminants will void the warranty on
the Sensor Cartridge.

4
switch is activated and/or the seal is
broken it will void all warranties.
8. Only remove replaceable parts as
listed in the parts and accessories.
Do NOT remove any part of the GX4,
especially the air inlet tting or the
power and auxiliary receptacles
under any circumstances. Removing
any part will void all warranties.
*Should the need arise, the unit must be
returned to RPB® Safety to perform any
repairs.
9. Sensors may contain sulfuric acid or
other hazardous chemicals which
are poisonous, can cause burns or
eyesight loss. Do not allow contact
with skin or eyes. If eyes are exposed
to the chemicals ush thoroughly
and seek medical attention. Always
wash hands thoroughly after
handling a sensor cartridge.
10. RPB® Safety cannot accept any
liability of whatsoever nature arising
directly or indirectly from the use
or misuse of RPB® Safety products,
including purposes that the
products are not designed for.
11. RPB® Safety is not liable for damage,
loss or expense resulting from the
failure to give advice or information
or the giving of incorrect advice or
information, whether or not due
to RPB® Safety’s negligence or that
of it’s employees, agents or sub-
contractors.
!WARNINGS!
1. When correctly installed and
maintained, the RPB® GX4 monitors
the level of relevant gasses in the
breathing air. It DOES NOT remove
any gasses from the air.
Only gasses relating to the inserted
cartridges can be detected. Ensure
you install all necessary cartridges
for your application.
2. Do not use this unit until you have
been trained in its operation by a
qualied individual appointed by
your employer. Failure to adhere to
the user’s instruction manual could
result in serious injury or death.
3. Leave work area immediately if the
monitor alarm sounds, check air
source and wait until alarm mode
stops. If it continues, verify sensor
calibration or change your air source.
4. The RPB® GX4 model 08-400 is not
approved for use in hazardous or
explosive atmospheres.
5. Do not cover the warning alarms
that are attached to the unit.
6. Regular testing of the alarm and
cartridges is required to detect
system failures and calibration.
Always wear hearing protection
when testing the alarm.
7. Do not open the monitor casing. The
unit is sealed closed and equipped
with a tamper switch. If the tamper

5
BEFORE YOU USE YOUR
GX4.
Unpack the unit from the shipping
carton and remove the shrink wrap
from the sensor cartridge. Read all
instructions and warnings that are
included with the unit. Dispose of the
removed packaging responsibly making
sure there is nothing important left
inside.
REGISTRATION:
Go to: http://go.myrpb.com/GX4-reg
to register your GX4 and be notied
of software updates and important
product information.
UPDATES
The GX4 rmware should be updated
regularly to ensure you have access
to the latest features and maintain
compatibility with the latest cartridges.
Visit http://go.myrpb.com/GX4-Update
for information on the latest software
and how to upgrade your unit.
SENSOR CHECK:
Checks should be performed when a
new cartridge is installed and monthly
thereafter. This will insure the cartridge
is within calibration and providing
adequate protection.
Follow the Sensor Check instructions
on page 17 to check the calibration
of the cartridges. If the cartridge is no
longer within calibration, follow the
instructions for removing it and replace
it with a new cartridge.
LOCATION
SETUP
Place the GX4 in a place that:
- The alarm can be heard
- Is protected from water and impact
See mounting instructions on pg. 8.

6
WIFI CONNECTION
To unleash the full power of the GX4, it is recommended to connect it to the internet
via the built-in wireless network transceiver. This connection allows easy rmware
upgrades and the unit hosts a website available to devices on that network. Use the
website to stream real-time gas levels, search through logs or print reports.
The GX4 can operate in two wireless modes. To select a mode in the Menu go to
Network and then Mode. Use the arrow keys to switch between modes and press OK
to select a mode. The unit will restart and resume operation in this network mode.
SETUP (CONTINUED)
Client Mode
Wireless
Router
or or
PC Tablet Smartphone
PC
GX4
Client Mode
Internet
Hotspot Mode
or or
PC Tablet Smartphone
GX4
Hotspot Mode
Internet
*Limited
Connectivity
PC
or
CLIENT MODE:
Use when you have access to a wireless
network {IEEE 802.11 b/g/n}.
- The GX4 must be connected to the
same network as your PC/Tablet/
Smartphone
- Access the GX4 website through
your internet browser.
- Multiple GX4s can be connected in
Client Mode to the same network
and each individual GX4 website
can be viewed on a seperate web
browser page.
HOTSPOT MODE:
Use to connect directly to your GX4
when you do not have access to an
existing network.
- The GX4 Hotspot Mode does not
connect to the internet.
- Devices can only connect to one
GX4 in Hotspot Mode at a time.
- For multiple GX4s, disconnect from
one before connecting to another.
Note: Although multiple devices can
connect, the GX4 is not a router. When
in Hotspot Mode your device can only
communicate to the host GX4.
To congure your network see page 15.

7
WEBSITE
The GX4 has an internal website that can be accessed by internet enabled devices.
This allows the user to view information about the unit and change settings such as
the network connection. This is your portal to access the full potential of the GX4.
To access the website for your GX4 from your internet connected device:
In Hotspot mode:
- Browse to http://192.168.1.3/
In Client mode:
- Locate the IP Address for your unit in the “About” menu.
- Make sure the GX4 and your internet enabled device are on the same network.
- Type the IP address into your internet browser, http://<IP Address>/
Features
The internal GX4 website provides the following features:
Dashboard Page
- Status of the unit (Power, Alarm, Auxiliary...)
- Network Conguration
- Change Wireless mode (O, Client, Hotsport)
- Change settings or connect to a dierent network
- Status of each cartridge
- Type of gas being monitored
- Current reading
- Last validation date
- Expiration date, and more
Logs
- Select a date(s) to view logs from
- Logs show events such as alarms, sensor checks, warnings, etc.
- Export visible logs as a CSV le for all logs or main events
Certicate of Calibration
- Printable report of the last sensor checks for each cartridge
- To save as a PDF, use a PDF printer driver or a browser with PDF functionality

8
SETUP (CONTINUED)
Position the monitor so that the green
brackets on the back line up with
the mounting bracket on the side of
the RADEX® , turn clockwise until the
monitor clicks into place.
Use the wall bracket (P/N: 08-231) and
appropriate screws to secure the wall
mounting bracket to a suitable wall.
MOUNTING TO A RADEX® FILTRATION UNIT
Figure 1.1
Figure 1.3
Figure 1.2
Position the monitor so that the green
brackets on the back line up with the
mounting bracket, turn clockwise until
the monitor clicks into place.
MOUNTING TO A WALL BRACKET

9
Insert the 3/8” O.D. Air Supply Hose (P/N:
08-428) into the push-lock tting on the
left side of the monitor. To disconnect,
press the outside ring of the push-lock
and pull the hose out. Note: Hose can be
trimmed to the desired length.
CONNECT THE AIR SUPPLY
Figure 2.1
When using Battery Clips (08-431),
connect:
- Black = Negative
- Red = +12V (± 0.5V)
1 2
+ -
Connect the power supply by screwing
it onto the receptacle on the left side
of the unit (next to the air inlet tting.)
Plug the AC Adaptor into a power
source.
Connect the air supply hose to a
GradeD air source regulated to between
7 to 80 PSI (50-550 kPa). Maximum air
ow is achieved at 20 PSI.
CONNECTING THE POWER SUPPLY
between 10-125psig.
Figure 3.1
Figure 2.2
Figure 3.2

10
If using an external alarm device,
connect the plug into the auxiliary
outlet. The use of an external alarm is
recommended when the GX4 cannot
be seen or heard by the operator. The
external alarm should be located near
the work area to alert the operators of
the status.
Alternatively, the auxiliary can control a
shut o valve, or other safety device.
Figure 4.1
CONNECT THE EXTERNAL ALARM
SETUP (CONTINUED)
To congure your own external device,
use the bare end AUX cable (08-434).
It is recommended to use a qualied
electrician when wiring to ensure you
do not damage the electrodes.
- Incorrectly wiring your auxiliary can
permanently damage your unit.
- Always use a qualied electrician.
- Damage to the auxiliary is not
covered under the manufacturer’s
warranty.
1. Brown - 12V DC
2. Blue - Alarm Out
3. Black - Ground
4. White - Alert Out
5. Green - OK Out
Figure 4.2