This user manual describes the following satellite system models:
●R&S®OSP-B200R Remote Control Module (order no. 1528.3140K02)
●R&S®OSP-B200R Remote Control Module with FOL (order no. 1528.3140K04)
●R&S®OSP-B200S2 Satellite Unit (order no. 1528.3134K02)
●R&S®OSP-B200S2 Satellite Unit with FOL (order no. 1528.3134K04)
It describes also the following satellite system accessories, see Chapter 4.3:
●R&S®OSP-B200P Power Supply (order no. 1528.3205.02)
●R&S®OSP-Z200x 5 m to 10 m Wired Link Cable (order no. 1528.3170.xx)
●R&S®OSP-Z201x 5 m to 40 m FOL Cable, SC/SC (order no. 1528.3186.xx)
●R&S®OSP-Z203xF 0.5 m to 40 m FOL Cable, SC/FSMA (order no. 1528.1690.xx)
●R&S®OSP-Z204xF 0.5 m to 40 m FOL Cable, FSMA/FSMA (order no. 1528.1702.xx)
© 2021 Rohde & Schwarz GmbH & Co. KG
Mühldorfstr. 15, 81671 München, Germany
Phone: +49 89 41 29 - 0
Email: [email protected]
Internet: www.rohde-schwarz.com
Subject to change – data without tolerance limits is not binding.
R&S® is a registered trademark of Rohde & Schwarz GmbH & Co. KG.
Trade names are trademarks of the owners.
1178.6733.02 | Version 03 | R&S®OSP-B200R/B200S2
Throughout this manual, products from Rohde & Schwarz are indicated without the ® symbol , e.g. R&S®OSP-B200R is indicated as
R&S OSP-B200R.

Contents
R&S®OSP-B200R/B200S2
3User Manual 1178.6733.02 ─ 03
Contents
1 Safety and Regulatory Information...................................................... 5
1.1 Safety Instructions........................................................................................................5
1.2 Labels on the Product.................................................................................................. 8
1.3 Warning Messages in the Documentation.................................................................. 8
1.4 Korea Certification Class B..........................................................................................9
2 Key Features.........................................................................................10
3 Documentation Overview.................................................................... 11
3.1 User Manual................................................................................................................. 11
3.2 Manuals of the Base Switch Units............................................................................. 11
3.3 Printed Safety Instructions.........................................................................................11
3.4 R&S OSP on the Internet............................................................................................ 11
3.5 Data Sheets and Brochures....................................................................................... 12
3.6 Application Notes, Application Cards.......................................................................12
3.7 Drivers..........................................................................................................................12
3.8 Release Notes and Open Source Acknowledgment................................................ 12
4 Hardware Description..........................................................................13
4.1 Remote Control Interface Module R&S OSP-B200R................................................ 13
4.2 Satellite Unit R&S OSP-B200S2................................................................................. 14
4.3 Accessories for the Satellite System........................................................................ 15
5 Preparing for Use.................................................................................17
5.1 Unpacking and Checking........................................................................................... 17
5.2 Mounting the RC Module into a Base Unit................................................................17
5.3 Mounting a Switch Module into the Satellite............................................................ 18
5.4 Connecting the Satellite System's Components......................................................19
6 Operating the Satellite System........................................................... 23
6.1 System Status............................................................................................................. 23
6.2 Power Consumption................................................................................................... 23
7 Transporting, Storage and Disposal.................................................. 24
7.1 Transporting................................................................................................................ 24

Contents
R&S®OSP-B200R/B200S2
4User Manual 1178.6733.02 ─ 03
7.2 Storage.........................................................................................................................24
7.3 Disposal....................................................................................................................... 24
8 Maintenance......................................................................................... 25
8.1 Cleaning....................................................................................................................... 25
8.2 Maintaining Flawless FOL Connections................................................................... 25
8.3 Contacting Customer Support...................................................................................27

Safety and Regulatory Information
R&S®OSP-B200R/B200S2
5User Manual 1178.6733.02 ─ 03
1 Safety and Regulatory Information
The product documentation helps you use the product safely and efficiently. Follow the
instructions provided here and in the Chapter 1.1, "Safety Instructions", on page 5.
Intended use
The R&S OSP-B200R/B200S2 is designated for switching and control applications,
including RF switching, in industrial, administrative, and laboratory environments. Use
the R&S OSP-B200R/B200S2 together with the R&S OSP base switch units, see
Chapter 2, "Key Features", on page 10, and only for its designated purpose.
Observe the operating conditions and performance limits stated in the data sheet.
Target audience
This document is targeted at all users, including installers, operators, and maintenance
personnel.
Where do I find safety information?
Safety information is part of the product documentation. It warns you of potential dan-
gers and gives instructions on how to prevent personal injury or damage caused by
dangerous situations. Safety information is provided as follows:
●In Chapter 1.1, "Safety Instructions", on page 5. The same information is provi-
ded in many languages as printed "Safety Instructions". The printed "Safety
Instructions" are delivered with the product.
●Throughout the documentation, safety instructions are provided when you need to
take care during setup or operation.
1.1 Safety Instructions
Products from the Rohde & Schwarz group of companies are manufactured according
to the highest technical standards. To use the products safely, follow the instructions
provided here and in the product documentation. Keep the product documentation
nearby and offer it to other users.
Use the product only for its intended use and within its performance limits. Intended
use and limits are described in the product documentation such as the data sheet,
manuals and the printed safety instructions. If you are unsure about the appropriate
use, contact Rohde & Schwarz customer service.
Using the product requires specialists or specially trained personnel. These users also
need sound knowledge of at least one of the languages in which the user interfaces
and the product documentation are available.
If any part of the product is damaged or broken, stop using the product. Never open
the casing of the product. Only service personnel authorized by Rohde & Schwarz are
allowed to repair the product. Contact Rohde & Schwarz customer service at http://
www.customersupport.rohde-schwarz.com.
Safety Instructions

Safety and Regulatory Information
R&S®OSP-B200R/B200S2
6User Manual 1178.6733.02 ─ 03
Lifting and carrying the product
The maximum weight of the product is provided in the data sheet. To move the product
safely, you can use lifting or transporting equipment such as lift trucks and forklifts. Fol-
low the instructions provided by the equipment manufacturer.
Choosing the operating site
Only use the product indoors. The product casing is not waterproof. Water that enters
can electrically connect the casing with live parts, which can lead to electric shock,
serious personal injury or death if you touch the casing. If Rohde & Schwarz provides a
carrying bag designed for your product, you can use the product outdoors.
Unless otherwise specified, you can operate the product up to an altitude of 2000 m
above sea level. The product is suitable for pollution degree 2 environments where
nonconductive contamination can occur. For more information on environmental condi-
tions such as ambient temperature and humidity, see the data sheet.
Setting up the product
Always place the product on a stable, flat and level surface with the bottom of the prod-
uct facing down. If the product is designed for different positions, secure the product so
that it cannot fall over.
If the product has foldable feet, always fold the feet completely in or out to ensure sta-
bility. The feet can collapse if they are not folded out completely or if the product is
moved without lifting it. The foldable feet are designed to carry the weight of the prod-
uct, but not an extra load.
If stacking is possible, keep in mind that a stack of products can fall over and cause
injury.
If you mount products in a rack, ensure that the rack has sufficient load capacity and
stability. Observe the specifications of the rack manufacturer. Always install the prod-
ucts from the bottom shelf to the top shelf so that the rack stands securely. Secure the
product so that it cannot fall off the rack.
Connecting to power
The product is an overvoltage category II product and has to be connected to a fixed
installation used to supply energy-consuming equipment such as household applian-
ces and similar loads. Be aware that electrically powered products have risks, such as
electric shock, fire, personal injury or even death.
Take the following measures for your safety:
●Before switching on the product, ensure that the voltage and frequency indicated
on the product match the available power source. If the power adapter does not
adjust automatically, set the correct value and check the rating of the fuse.
●If a product has an exchangeable fuse, its type and characteristics are indicated
next to the fuse holder. Before changing the fuse, switch off the instrument and dis-
connect it from the power source. How to change the fuse is described in the prod-
uct documentation.
Safety Instructions

Safety and Regulatory Information
R&S®OSP-B200R/B200S2
7User Manual 1178.6733.02 ─ 03
●Only use the power cable delivered with the product. It complies with country-spe-
cific safety requirements. Only insert the plug into an outlet with protective conduc-
tor terminal.
●Only use intact cables and route them carefully so that they cannot be damaged.
Check the power cables regularly to ensure that they are undamaged. Also ensure
that nobody can trip over loose cables.
●If the product needs an external power supply, use the power supply that is deliv-
ered with the product or that is recommended in the product documentation or a
power supply that conforms to the country-specific regulations.
●Only connect the product to a power source with a fuse protection of maximum
20 A.
●Ensure that you can disconnect the product from the power source at any time.
Pull the power plug to disconnect the product. The power plug must be easily
accessible. If the product is integrated into a system that does not meet these
requirements, provide an easily accessible circuit breaker at the system level.
Cleaning the product
Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that the
casing is not waterproof. Do not use liquid cleaning agents.
Meaning of safety labels
Safety labels on the product warn against potential hazards.
Potential hazard
Read the product documentation to avoid personal injury or product damage.
Electrical hazard
Indicates live parts. Risk of electric shock, fire, personal injury or even death.
Hot surface
Do not touch. Risk of skin burns. Risk of fire.
Protective conductor terminal
Connect this terminal to a grounded external conductor or to protective ground. This protects
you against electric shock should an electric problem occur.
Using laser products
Warning: laser beam
The product contains a laser.
Avoid exposure to direct or reflected laser beam.
Lasers are classified according to their potential risk.
Safety Instructions

Safety and Regulatory Information
R&S®OSP-B200R/B200S2
8User Manual 1178.6733.02 ─ 03
Class 1M lasers
Safe for the naked eye. If you look into the laser beam with optical instruments such as
binoculars or eye loupes, you risk damaging your eyes.
Class 2 lasers
If you stare into the beam, you risk damaging your eyes.
1.2 Labels on the Product
Labels on the casing inform about:
●Personal safety, see Table 1-1
and "Using laser products" on page 7
●Product and environment safety, see Table 1-1
●Identification of the product by the label that bears a bar code
Table 1-1: Labels regarding product and environment safety
Labeling in line with EN 50419 for disposal of electrical and electronic equipment after the prod-
uct has come to the end of its service life. For more information, see "Disposing electrical and
electronic equipment" on page 24.
"Environment Friendly Use Period" (EFUP) according to the China "Restriction of Hazardous
Substances" (RoHS) regulations. Here, 25 is the number of years before any of the RoHS sub-
stances (lead, mercury, cadmium etc.) are likely to leak out, causing possible harm to health
and the environment.
1.3 Warning Messages in the Documentation
A warning message points out a risk or danger that you need to be aware of. The sig-
nal word indicates the severity of the safety hazard and how likely it will occur if you do
not follow the safety precautions.
CAUTION
Potentially hazardous situation. Could result in minor or moderate injury if not avoided.
NOTICE
Potential risks of damage. Could result in damage to the supported product or to other
property.
Warning Messages in the Documentation

Safety and Regulatory Information
R&S®OSP-B200R/B200S2
9User Manual 1178.6733.02 ─ 03
1.4 Korea Certification Class B
이 기기는 가정용(B급) 전자파 적합기기로서 주로 가정에서 사용하는 것을 목적으로 하
며, 모든 지역에서 사용할 수 있습니다.
Korea Certification Class B

Key Features
R&S®OSP-B200R/B200S2
10User Manual 1178.6733.02 ─ 03
2 Key Features
The R&S OSP-B200R and R&S OSP-B200S2 satellite system is the transparent
extension of two R&S OSP module slots via a cable connection or fiber-optic link.
Advantages of this satellite system are:
●You can operate and control RF relays "on-site" at the shortest possible distance
from other test equipment, for example in a shielded test chamber
●The non-conductive fiber-optic control link avoids electromagnetic interference
●The fiber-optic cables allow long-distance connections
●The fiber-optic cables easily feed through the shielding of anechoic chambers
Base unit required
You can operate the satellite options R&S OSP-B200R and R&S OSP-B200S2 only in
connection with one of the following base switch units:
●R&S OSP120, R&S OSP130 or R&S OSP150 (1st generation)
●R&S OSP220, R&S OSP230 or R&S OSP320 (2nd generation)
For all information related to these switch units, refer to the R&S OSP user manuals.
This manual describes the satellite options for the R&S OSP family:
●R&S OSP-B200R (order no. 1528.3140K02 / K04)
Remote control module for one satellite R&S OSP-B200S2
●R&S OSP-B200S2 (order no. 1528.3134K02 / K04)
Satellite unit with two standard R&S OSP module slots
It describes also the satellite system's accessories, including cables and power supply.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Mando a distancia de Rohde & Schwarz