RocwooD RWPG1E Manual de usuario

RocwooD
Instruction Manual
NOTE: PLEASE READ INSTRUCTIONS CAREFULLY BEFORE USE.
POWER
GENERATOR

INTRODUCTION
DANGER
DANGER DANGER
WARNING
WARNING
[CAUTION]
Indicates a possibility of death or serious injury if instructions are not followed.
Indicates a strong possibility of severe personal injury, loss of life and equipment damage if instructions
are not followed.
• The generator is designed to give safe and dependable service if operated according to instructions.
• Do not operate the generator before you have read and understood the instructions. Failure to do so
could result in death, personal injury or equipment damage.
Indicates a possibility of personal injury or equipment damage if instructions are not followed.
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a
poison you cannot see or smell.
Never let spilt fuel REACH HOT PART of Generator.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
Only use OUTSIDE and
far away from windows,
doors, and vents.
NOTE :
Gives helpful information.
If a problem should arise, or if you have any questions about the generator, consult an authorized dealer
or service shop

SAFETY INSTRUCTIONS
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
Please make sure you review each precaution carefully.
Do not operate the generator near fuel because of the potential danger of explosion or re. Do not ll
the fuel tank with fuel while the engine is running. Do not smoke or use naked ame near the fuel tank.
Be careful not to spill fuel during refueling. If fuel is spilt, wipe it o and let dry before starting the engine.
Do not place ammables near the generator.
Be careful not to place fuel, matches, gunpowder, oily cloths, straw, trash, or any other in ammables
near the generator.
Do not enclose the generator nor cover it with a box. The generator has a built-in forced air cooling
system, and may become overheated if it is enclosed. If generator has been covered to protect it from the
weather during non use, be sure to remove it and keep it well away from the area during generator use.
Operate the generator on a level surface.
It is not necessary to prepare a special foundation for the generator. However, the generator will vibrate
on an irregular surface, so choose a level place without surface irregularities. If the generator is tilted
or moved during operation, fuel may spill and / or the generator may tip over, causing a hazardous
situation. Proper lubrication cannot be expected if the generator is operated on a steep incline or slope.
In such a case, piston seizure may occur even if the oil is above the upper level.
Pay attention to the wiring or extension cables from the generator to the connected device. If the wire is
under the generator or in contact with a vibrating part, it may break and possibly cause a re, generator
burnout, or electric shock hazard. Replace damaged or worn cables immediately.
Do not operate in rain, in wet or damp conditions, or with wet hands. The operator may suer severe
electric shock if the generator is wet due to rain or snow.
Do not operate the generator inside a room, cave, tunnel, or other insuciently ventilated area.
Always operate it in a well-ventilated area, otherwise the engine may become overheated, and the
poisonous carbon monoxide gas an odorless, colorless, poison gas, contained in the exhaust gas will
endanger human lives. Operate generator only outdoors and far from open windows, doors,
ventilation intakes and other openings. Keep the generator at least 1 metre (3 feet) away , including
overhead, from any structure or building use.

WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
If wet, wipe and dry it well before starting. Do not pour water directly over the generator, nor wash it
with water.
Be extremely careful that all necessary electrical grounding procedures are followed during each and
every use. Failure to do so can be fatal.
Do not contact the generator to a commercial power line. Connection to a commercial power line
may short circuit the generator and ruin it or cause electric shock hazard. Use the transfer switch for
connecting to domestic circuit.
No smoking while handling the battery. The battery emits ammable hydrogen gas, which can explode
if exposed to electric arcing or naked ame. Keep the area well-ventilated and keep naked ames/sparks
away when handling the battery.
Engine becomes extremely hot during and for some time after operation. Keep combustible materials
well away from generator area. Be very careful not to touch any parts of the hot engine especially the
muer area or serious burns may result.
Keep children and all bystanders at a safe distance from work areas.
It is absolutely essential that you know the safe and proper use of the power tool or appliance that you
intend to use. All operators must read, understand and follow the tool/appliance owners manual. Tool
and appliance applications and limitations must be understood. Follow all directions given on labels and
warnings. Keep all instruction manuals and literature in a safe place for future reference.
Use only “LISTED” extension cables. When a tool or appliance is used outdoors, use only extension
cables marked “For Outdoor Use”. Extension cables, when not in use should be stored in a dry and well
ventilated area
Always switch o generator’s AC circuit breaker and disconnect tools or appliances when not in use,
before servicing, adjusting, or installing accessories and attachments.
Make sure the engine is stopped before starting any maintenance, servicing or repair. Make sure
maintenance and repair of the generator set are performed by properly trained personnel only.
SAFETY INSTRUCTIONS

Specications are subject to change without notice.
SPECIFICATIONS
Maximum Output: 2800W/2.8kW/3.4KVA
Voltage Regulator: Automatic voltage regulator
Emergency Indicator: Auto breaker overload protection
Safety Measures: Low oil automatic shut down
Continuous Rated Output: 2600W/2.6kW
Rated Voltage: 220V
Fuel Tank Capacity: 11 Litres
Oil Capacity: 0.6L
Oil Type: 10W30 or 10W40
Engine Type: Single-Cylinder, 4-Stroke, Air-Cooled, OHV horizontal shaft
Engine Output: 8hp
Engine displacement: 210cc
Starting System: Electric
Continuous Operating Time: 10h
Noise Level: 66dB
RocwooD Electric Start Model: RWPG1E
RocwooD Recoil Start Model: RWPG1
Maximum Output: 2800W/2.8kW/3.4KVA
Voltage Regulator: Automatic voltage regulator
Emergency Indicator: Auto breaker overload protection
Safety Measures: Low oil automatic shut down
Continuous Rated Output: 2600W/2.6kW
Nominal Current: 12.7A
Rated Voltage: 220V
Fuel Tank Capacity: 11 Litres
Oil Capacity: 0.6L
Oil Type: 10W30 or 10W40
Engine Type: Single-Cylinder, 4-Stroke, Air-Cooled, OHV horizontal shaft
Engine Output: 8hp
Engine displacement: 210cc
Starting System: Recoil
Continuous Operating Time: 10h
Noise Level: 66dB

COMPONENTS
1. Fuel tank
2. Fuel valve
3. Air filter cover
4. Choke lever
5. Engine switch
6. Oil filler plug
7. Recoil starter handle
8. AC sockets
9. Volt
10. AC circuit breaker
11. DC circuit breaker
12. DC output
1
2
3
4
56
7
8
11 12
9
10

PRE OPERATION CHECKS
CHECK ENGINE OIL
RECOMMENDED ENGINE OIL :
Before checking or relling oil, be sure generator is located on
stable and level surface with engine stopped.
• Remove oil ller cap and check the engine oil level.
• If oil level is below the lower level line, rell with suitable
oil (see table) to upper level line. Do not screw in the
oil ller cap when checking oil level.
• Change oil if contaminated. (See “How-To” Maintenance.)
Use 4-stroke automotive detergent oil of API service class SE or higher grade (SG, SH or SJ is
recommended). SAE 10W-30 or 10W-40 is recommended for general, all-temperature use. If single
viscosity oil is used, select the appropriate viscosity for the average temperature in your area
Oil capacity (Upper level) : 0.6L / 0.15Gal

PRE OPERATION CHECKS
CHECK ENGINE FUEL
Use 4-stroke automotive detergent oil of API service class SE or higher grade (SG, SH or SJ is
recommended). SAE 10W-30 or 10W-40 is recommended for general, all-temperature use. If single
viscosity oil is used, select the appropriate viscosity for the average temperature in your area
Do not refuel while smoking or near naked ame or other such potential re hazards. Otherwise re
accident may occur
WARNING
Make sure you review each warning in order to prevent re hazard.
• Do not rell tank while engine is running or hot.
• Close fuel valve before refueling with fuel.
• Be careful not to admit dust, dirt, water or other foreign objects Into fuel.
• Wipe o spilt fuel thoroughly before starting engine.
• Keep naked ames away
WARNING
NOTE :
THIS ENGINE IS CERTIFIED TO OPERATE
ON AUTOMOTIVE UNLEADED GASOLINE.
Fuel Amount
up to “LEVEL” position : (15L/3.95Gal)
• Check fuel level at fuel level gauge.
• If fuel level is low, rell with unleaded automo-
tive gasoline.
• Be sure to use the fuel lter screen on the fuel
lter neck.

PRE OPERATION CHECKS
CHECKING COMPONENT PARTS
BATTERY INSTALLATION (Electric Starter Model)
CHECK GENERATOR SURROUNDINGS
Check following items before starting engine:
• Fuel leakage from fuel hose, etc.
• Bolts and nuts for looseness.
• Components for damage or breakage.
• Generator not resting on or against any adjacent wiring
• Recommended Battery
• Type : Lead-acid battery
• Capacity (Ah) : 12V,7AH or more
• Size : Less than 190(L) x 90(W) x 175(H) mm
Make sure you review each warning in order to prevent re hazard.
• Keep area clear of in ammables or other hazardous materials.
• Keep generator at least 3 feet (1 metre) away from buildings or other
structures.
• Only operate generator in a dry, well ventilated area.
• Keep exhaust pipe clear of foreign objects.
• Keep generator away from naked ame. No smoking!
• Keep generator on a stable and level surface.
• Do not block generator air vents with paper or other material.
WARNING

PRE OPERATION CHECKS
GROUNDING THE GENERATOR
•GROUNDING SPIKE NOT SUPPLIED!•To ground the generator to the earth, connect the grounding lug of the generator to the grounding spike driven into the earth or to the conductor which has been already grounded to the earth.
• If such grounding conductor or grounding electrode is unavailable, connect the grounding lug of the generator to the grounding terminal of the using electric tool or appliance.
•If using this as a portable generator for tools and standalone items, the grounding spike is not needed.•The grounding spike is only required if plugging into your homes/buildings electrical supply, you will also require a transfer switch if plugging into homes/buildings.Death, personal injury and/or property damage may occur unless instructions are followed
carefully.
• Use battery of recommended capacity.
• Turn the starter switch to the “STOP” position when mounting or dismounting battery. When
mounting battery, connect the positive (+) cable rst and then the negative (-) cable to the battery.
Be careful not to short battery cables. When dismounting battery, disconnect negative (-) cable rst.
RED CABLE : To positive (+) terminal
BLACK CABLE : To negative (-) terminal
• Should the connection be made in incorrect manner, the generator will be broken.
• Tighten bolts and nuts on terminals securely so they will not be loosened by vibration.
• Disconnect battery cables when charging battery
WARNING
Este manual sirve para los siguientes modelos
1
Tabla de contenidos