Robert Juliat TIBO-525 Manual de usuario

TIBO - 525 - Version V1
HID FRESNEL LENS - 250 W /
PROJECTEUR FRESNEL A DECHARGE 250 W
SINGLE LENS LUMINAIRE /
PROJECTEUR FRESNEL
VALIDATION : 09/04/15
DN41044300
Robert Juliat S.A.S. 32, rue de Beaumont, F 60530 Fresnoy-en-Thelle - phone : +33 (0)3 44 26 51 89 - fax : +33 (0)3 44 26 90 79 - [email protected]
www.robertjuliat.com
TIBO
Manual / Manuel
Reference Standard
Référence Standard
250 W HID (G12) 525

Robert Juliat reserve the right to change or alter any of the items detailed on this page,
to increase or improve manufacturing techniques without prior notice.
Table of Contents
1 User’s instructions................................................................................................................. 1
2 Presentation .......................................................................................................................... 2
2.1 Functions ....................................................................................................................... 2
2.2 Identication label ....................................................................................................... 2
2.3 Accessories included..................................................................................................... 3
2.4 Optional accessories .................................................................................................... 3
3 Set-up ................................................................................................................................ 4
3.1 Mechanics...................................................................................................................... 4
3.1.1 Operating positions
.................................................................................................................................. 4
3.1.2 Minimum distance between a ammable material and the lighting unit
........... 4
3.1.3 Instructions for use
................................................................................................................................... 4
3.1.4 Hanging
............................................................................................................................................................ 5
3.1.5 Safety cable
.................................................................................................................................................... 5
3.2 Electrical data ............................................................................................................... 6
3.2.1 Lamp
................................................................................................................................................................... 6
3.2.2 Power Supply
................................................................................................................................................. 7
3.3 Accessories .................................................................................................................... 8
3.3.1 Front lter holder and barndoors
..................................................................................................... 8
3.3.1 Front lter holder
........................................................................................................................................ 8
3.3.2 Barndoors
........................................................................................................................................................ 8
4 Operation............................................................................................................................... 9
4.1 Beam size adjustment.................................................................................................. 9
4.1.1 Range
................................................................................................................................................................ 9
4.1.2 Control
............................................................................................................................................................... 9
4.2 Orientation..................................................................................................................10
4.2.1 Range
..............................................................................................................................................................10
4.2.2 Control
.............................................................................................................................................................10
4.4 Beam shaping (Barndoors)........................................................................................11
4.4.1 Range.................................................................................................................................11
4.3 Colour...........................................................................................................................11
4.4.2 Control...............................................................................................................................12
5 Service ..............................................................................................................................12
5.1 Preventive maintenance............................................................................................12
5.1.1 Frequency
.....................................................................................................................................................12
5.1.2 General visual check
...............................................................................................................................12
5.2 Analysis........................................................................................................................12
5.3 Exploded view / Spare parts list ................................................................................12
6 Troubleshooting .................................................................................................................13

EN
EN - 1 -
1 User’s instructions
GENERAL INSTRUCTIONS
1. Not for residential use.
2. These fixtures must only be serviced by a qualified technician.
3. In addition to the instructions indicated on this page, relevant health and safety requirements of the appropriate EU
Directives must be adhered to at all times.
4. This fixture is in compliance with section 17 – Lighting appliance for theatre stages, television, cinema and photograph
studios. Standards NF EN 60598-1 and NF EN 60598-2-17.
5. This fixture is rated as IP20, and is for indoor use only.
FIXTURE
6. Warning: disconnect from mains supply before servicing.
7. Ensure fixture is correctly mounted on an appropriate support.
8. Protection screens, lenses and filters must be replaced in the event of any damage, such as cracks or deep scratches,
since these might reduce performance.
9. When hung or flown the fixture must be secured by an additional hanging accessory (such as a safety cable or bond) of suitable
length.
10. Safety bonds or cables must be securely attached to the back of the fixture and be as short as possible, or rolled up as necessary,
to minimise travel distance should the fixture be dislodged.
11. Movable accessories (barn doors, spill rings etc.) must also be secured with a suitable safety cable or bond at the front of the
fixture.
12. The combined weight of both the fixture and the accessories must be considered when choosing the load-bearing
capability of safety cable or bond.
13. Do not open lighting fixture when the lamp is ignited.
14. Warning: Both lamp and lamp housing become hot during use. Allow fixture to cool before servicing
15. Do not tamper with design of fixture nor any of its safety features.
16. Tighten electrical mains cable connections regularly and replace with one of identical specification if damaged.
17. Use only with correct power supply.
VENTILATION
18. Keep well away from flammable material.
19. Not for outdoor use. Do not cover. Do not permit fixture to get wet.
20. To avoid overheating, do not obstruct air vents.
21. Ensure any cooling fans are in correct working order. If fans are not working, turn fixture off immediately and service as necessary.
LAMP
22. Check that the lamp voltage corresponds to the mains voltage used. Only use a lamp of type and voltage indicated on lamp
housing or packaging.
23. Replaced lamp if damaged or deformed by heat.
24. Ensure lamp is correctly fitted before use.
CLEANING
25. Clean all optical parts (lenses, lamps, etc.) with alcohol-based cleaner.
26. Regularly remove dust from mirror with a soft, clean cloth.
27. Clean all filters regularly.
PLEASE NOTE
These products have been built to conform to European standards relating to professional lighting equipment. Any modification
made to our products will void the manufacturers' warranty.

EN
EN - 2 -
2 Presentation
2.1 Functions
2.2 Identication label
Functions
Description
1. Handle
2. Hanging yoke
3. Tilt locking handle
4. Beam angle adjustment
5. Safety cable attachment point
6. Unit rotation locking button
7. Tilt index
8. Front slot locking system
9. Front slot for accessory and gel frame
10. Safety cable attachment point for
accessories
1. Serial number
2. Version

EN
EN - 3 -
2.3 Accessories included
2.4 Optional accessories
Reference Description
1 PF100M 138x138 mm metal filter holder
Reference Description
1 PCP1716A 16A blue 2P+E 6h IEC60309 (P17) power connector
2 CF100 4 leaves on a barndoor - 135x135mm (without safety cable)
3 872 Doughty Twenty clamp with M10 screw/nut for Ø48 to 51mm
pipes - SWL: 20Kg - TÜV approved
4 878 Hook clamp 25x6mm with 23mm M10 screw for Ø35 to 50mm
pipes - SWL: 11Kg
5 CS2 Safety cable Ø3 mm L= 600mm - SWL: 75 Kg
1
1
4
2
5
3

EN
EN - 4 -
3 Set-up
3.1 Mechanics
3.1.1 Operating positions
3.1.2 Minimum distance between a ammable material and the lighting unit
3.1.3 Instructions for use
Minimum :
40°C
104°F
5°C
41°F
IP20 - Indoor use only
Maximum :
0.5 m
1,6 ft

EN
EN - 5 -
3.1.4 Hanging
• Ensure fixture is correctly mounted on an appropriate support.
Net weight :
- Fixture with power supply = 7,4 kg (16,3 lbs)
- Power supply = 2 Kg (4,4 lbs)
3.1.5 Safety cable
• When hung or flown, the fixture must be secured by an additional hanging
accessory (such as safety bond or cable) of suitable length.
• Safety cables or bonds must be securely attached to the back of the fixture and be as
short as possible, or rolled up as necessary, to minimise travel distance should the
fixture be dislodged
NOTA:
The indicated attachment points are symmetrical.
Warning : attachment point for
accessories only
Do not use as a hanging point
to secure the fixture.
Ø13,20 mm

EN
A
B
EN - 6 -
Compatible lamps
Designation Ref. Colour
Code Socket Voltage Power Lumen
output
Colour
Temperature Lamp life
3.2 Electrical data
3.2.1 Lamp
How to place the lamp
• Electrically insulate prior to any intervention. Intervention must be carried out by a skilled technician.
• Caution : lamp and supports can be hot. The fixture must be cold prior to any intervention.
• Never touch or handle the lamp bulb with bare hands.
1. Unscrew the 2 screws A of the lamp compartment.
2. Pull the lamp compartment out.
3. Place the lamp into the socket.
4. Place the lamp compartment to the fixture, making sure that ground wire is correctly connected B .
5. Tighten the 2 screws A of the lamp compartment.
Warning:
Warm white CDM-T 830 G12 95 V 250 W 23 000 lm 3000 K 8000 h
Neutral white CDM-T (Philips) 942 G12 93 V 250 W 23 300 lm 4200 K 8000 h

EN
EN - 7 -
Power Supply
Model Voltage Frequency Current
525 230 V 50 Hz 250 W lamp: 1,2 A
3.2.2 Power Supply
• Class 1 equipment. Mandatory earth grounding.
• Can be connected to an external electronic dimmer
Power cable
Cable Connectors Cable reference Length Cabling
1Standard
Version -H07RNF
3G1.5
1,5 m
4.9 ft
Phase: brown
Neutral: blue
Ground: yellow, green

EN
EN - 8 -
3.3 Accessories
3.3.1 Front lter holder and barndoors
Step 1
3.3.1 Front lter holder
3.3.2 Barndoors
Step 2
Tabla de contenidos
Idiomas:
Otros manuales de Linterna de Robert Juliat