Robe Anolis E-box Remote Basic Manual de usuario

1
Version 1.7
QR code for user manual

2
E-box Remote
Table of contents
1. Safety information ............................................................................................................ 3
2. Fixture description............................................................................................................ 4
3. Mounting............................................................................................................................ 6
4. Eminere Remote modes ................................................................................................... 9
5. E-box Remote menu ....................................................................................................... 13
5.1 DMX Addr ................................................................................................................... 14
5.2 Info ............................................................................................................................. 14
5.3 Personality ................................................................................................................. 15
5.4 Test programs ............................................................................................................ 16
5.5 Special settings .......................................................................................................... 16
6. Software update .............................................................................................................. 17
7. Technical specifications ................................................................................................. 20
8. Disposing of the product ............................................................................................... 21
9. Change Log ..................................................................................................................... 21

3
1. Safety information
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the fixture.
Always disconnect the fixture from AC power before removing its cover.
Do not install the fixture near an open flame.
This fixture falls under protection class I. Therefore, this fixture has to be connected to a mains socket outlet
with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
Do not cover the fixture with cloth or other materials.
The fixture was designed for outdoor use, and it is intended for professional application only. It is not for
household use.
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
Only operate the fixture after having checked that the housing is firmly closed, and all screws are tightly fastened.
Operate the fixture only after having familiarized yourself with its functions. Do not permit operation by persons
not qualified to operate the fixture. Most damages are the result of unprofessional operation!
Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the warranty becomes void. Furthermore, any other operation may lead to dangers like
short-circuit, burns, electric shock etc.
Immunity of the equipment is designed for electromagnetic environments E1, E2, E3, according to the
standard EN55103-2 ed.2 - Electromagnetic compatibility. Product family standard for audio, video, audiovisual
and entertainment lighting control apparatus for professional use. Part 2: Immunity.
The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m
The installation company should check levels of possible interferences above the tested levels E1, E2, E3
given by this standard (e.g., transmitters in surrounding area), before installing the equipment.
Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia
equipment – Emission Requirements according to class B.
The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m
ATTENTION!
Risque de choc. Couper L’alimentation avant L’entretien.
Non destine a à un usage domestique
Convient aux emplacements mouillés.
Ce produit doit être installé selon le code d'installation pertinent,par une personne qui connaît bien les produit et
son fonctionnement ainsi que les risques inhérents.
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR E-box Remote!
Save it for future reference.

4
2. Fixture description
A - Top cover
B - Top cover screws
C - Mounting holes
D - Antenna cover
E - Display
F - Control buttons
G - Screws of terminal blocks cover
H - Terminal blocks cover
1 - LED Output 1 (cable gland M20x1.5)
2 - LED Output 2 (cable gland M20x1.5)
3 - Power IN (cable gland M20x1.5)
4 - DMX OUT (cable gland M12x1.5)
5 - DMX IN (cable gland M12x1.5)
6 - Ethernet OUT (cable gland M12x1.5)
7 - Ethernet IN (cable gland M12x1.5)
View without top cover

5
Connection points

6
3. Mounting
Note for cable glands.
We recommend applying an adequate layer of the paste LOCTITE 5331 on the plastic holder of the
cable gland before inserting it into the body of the gland and an adequate layer of the paste LOCTITE 577 on
the thread of the gland body.
1. Remove the top cover (A) from the E-box Remote by unscrewing four fastening screws (B) in order to
get access to the display (E), control buttons (F).
2. Fasten the E-box Remote on a non-flammable flat surface via four mounting holes (C) of
a diameter of 7 mm in its housing.
3. Remove the terminal blocks cover (H) from the E-box Remote by unscrewing four fastening screws (G)
in order to get access to the terminal blocks.
4. Remove end caps from cable glands before passing cables. To keep declared IP rating of the device,
every cable gland has to be covered with the end cap if the cable gland is not used.
5. Pass cables for DMX and Ethernet through cable glands M12x1.5 and connect them to the terminal blocks
and tighten the cables in the cable glands.
6. Pass cables for Power and LED outputs through cable glands M20x1.5 and connect them to the terminal blocks
and tighten the cables in the cable glands.
Cable glands serve for cables of the following diameters:
Cable gland M12x1.5 (DMX IN/OUT, Ethernet IN/OUT) - for cable of a diameter of 3-7mm.
Cable gland M20x1.5 (Power IN, LED Output) - for cable of a diameter of 7-13mm.
7. Check that all screws and cable glands are firmly tightened.
8. Screw the terminal blocks cover (H) back to the E-box Remote.
9. Connect the E-box Remote to mains.
10. Set the E-box Remote by means of the control panel (E) and buttons (F).
11. Disconnect the E-box Remote from mains and screw the cover (A) back on the box.
Power connection
L N
Wire (CE) Brown Blue Green/yellow
Wire (US) Black White Green
This device falls under protection class I. Therefore, every E-box Remote
has to be connected to a mains socket outlet with a protective earthing connection
Fixture must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulations.
Setting and addressing the E-box Remote without top cover can be done by
a
qualified person
only!
ALWAYS DISCONNECT THE E-BOX REMOTE FROM MAINS BEFORE
CONNECTING/DISCONNECTING LED MODULES

7
DMX connection
D+ D- 0V
Data + Data - Data ground (shielding)
Ethernet connection
Pin 1 2 3 4 5 6 7 8
Function TX+ TX- RX+ NC NC RX- NC NC
Eminere Remote connection
CE version:
Mark Function Wire
Vcc LEDs + Red
D+ DATA + Orange
D- DATA - White
0V LEDS - Black
Ground Not connected
US version:
Mark Function Wire
Vcc LEDs + Red
D+ DATA + Orange
D- DATA - White
0V LEDS - Black
Ground Green
Example of connection

8
NOTE: Each line of Emineres Remote connected to the LED output of the E-box Remote has to be terminated at
the last fixture.
EITHER connect a 120 Ohm resistor between terminals D+ and D- in the last fixture, OR terminate via RDM as
described on page 12.
Ensure ONLY the last fixture in the line is terminated using ONE of the above methods!
Number of connected Emineres to one LED output of the E-box Remote depends on the type of Eminere
Remote and cable length.
The table states max. number of Eminere Remote modules connected to the E-box Remote.
Max. number of Emineres Remote connected to the E-box Remote
Cable length * Eminere Remote 1 Eminere Remote 2 Eminere Remote 3 Eminere Remote 4
25 m 20 10 6 5
50 m 16 8 5 4
75 m 13 6 4 3
100 m 10 5 3 2
* Cable length is the total cable length between E-box Remote and last connected Eminere Remote.
Example: Total cable length = L1+L2+L3+L4
Max. number of Eminere Remote modules connected to the one output of the E-box Remote/E-box Remote Basic is stated
in the following table:
Max. number of Emineres Remote connected to the one output of the E-box Remote
Eminere Remote 1
Eminere Remote 2 Eminere Remote 3 Eminere Remote 4
16 8 5 4
Example: if you want to connect 20 Emineres Remote 1 to the E-box Remote, you may connect 16 Emineres Remote 1 to
output 1 and 4 Emineres Remote 1 to output 2 (at total cable length of 25 m).

9
4. Eminere Remote modes
The E-box Remote menu allows you to switch connected Emineres Remote to the two modes:
Standard - LED modules are switched to an internal serial connection. DMX addressing of connected LED
modules is made automatically (default DMX address = 1, changes can be done by the E-box Remote or by
RDM). The Standard mode is set as default.
E-box Remote and connected LED modules will be shown in the RDM Manager.
Pass-Thr - (Pass through). LED modules are switched to an internal parallel connection. DMX addressing of
connected LED modules has to be done manually by means of the Robe Universal Interface (or its wireless
version Robe Universal Interface WTX) and the software RDM Manager.
Only connected LED modules will be shown in the RDM Manager.
Note: RDM manager and DMX controller cannot be connected to the E-box Remote at the same time.
Example of RDM manager connection:

10
Examples of RDM manager screenshots.
Initial screen of the RDM manager – Standard mode:
Initial screen of the RDM manager – Pass Through mode:
E-box Remote is shown
Connected LED
module(s) is (are) shown
Only connected LED
module(s) is (are) shown
Otros manuales para Anolis E-box Remote Basic
2
Tabla de contenidos
Otros manuales de Mando a distancia de Robe