RM FTH 708 G Manual de usuario

INSTRUCTIONS FOR INSTALLATION AND USE
DIE GEBRAUCHS-, UND INSTALLATIONSANWEISUNG
NOTICE D’INSTALLATION ET D’EMPLOI
www.rmgastro.com
GAS GRIDDLE PLATES
FTH 708 G / FTH 704 G / FTH 740 G / FTHC 704 G
FTHC 708 G / FTHC 740 G / FTHR 708 G
FTHR 780 G / FTHRC 780 G / FTR 704 G / FTR 708 G
FTR 740 G / FTR 780 G / FTRC 704 G / FTRC 740 G
FTRC 780 G / FTHC 780 G / FTHRC 708 G
FTRC 708 G / FTH 780 G / FTH 712 G / FTR 712 G /
FTHR 712 G / FTHC 712 G / FTRC 712 G /
FTHRC 712 G / FTH 7012 G / FTR 7012 G /
FTHR 7012 G / FTHC 7012 G / FTRC 7012 G /
FTHRC 7012 G
Date: 2018

CONTENT
DECLARATION OF A STANDARDS CONFORMITY 3
INSTRUCTION FOR USE 11
CLEANING AND MAINTENANCE 12
DIE NORMENÜBEREINSTIMMUNGSDEKLARATION 13
GEBRAUCHSANWEISUNG 20
REINIGUNG UND WARTUNG 21
DÉCLARATION DE CONFORMITÉ 22
MODE D´EMPLOI 29
ENTRETIEN 30

3
DECLARATION OF A STANDARDS CONFORMITY
The producer confi rms that the devices agree with 2016/426/EU, 2014/35/EU, 2014/30/EU standards, rule
nr. 22/1997 sb., 258/2000 sb, 38/2001 sb, 118/2016 sb., 117/2016 sb. and with relevant goverment orders.
Instalation must be done with respect to valid standards. Attention, the producer refuses any responsibility
in case of direct or indirect damages which are caused due to wrong instalation, incorrect intervention or
modifi cation, insuffi cient maintenance, incorrect use and also possibly caused by other reasons presented by
items in sale conditions. This appliance is set only for skilled use and must be operated by qualifi ed persons
only. Parts set and secured by the producer or accredited person must not be rebuilt by user.
TECHNICAL DATA
Label with technical data is placed on the back side of the device. Study the electrical diagram of connection
and all following information before instalation.
3

4
Type of product Burner performance Power
(kW)
Dimmensions
(mm)
FTH- 704 G 1x 7Kw 7 400 x 758 x 378
FTH- 708 G 2x 7Kw 14 800 x 758 x 378
FTH- 740 G 1x 7Kw 7 400 x 758 x 957
FTH- 780 G 2x 7Kw 14 800 x 758 x 957
FTH- C-704 G 1x 7Kw 7 400 x 758 x 378
FTH- C-708 G 2x 7Kw 14 800 x 758 x 378
FTH- C-740 G 1x 7Kw 7 400 x 758 x 957
FTH- C-780 G 2x 7Kw 14 800 x 758 x 957
FTHR- 708 G 2x 7Kw 14 800 x 758 x 378
FTHR- 780 G 2x 7Kw 14 800 x 758 x 957
FTHR- C-708 G 2x 7Kw 14 800 x 758 x 378
FTHR- C-780 G 2x 7Kw 14 800 x 758 x 957
FTR- 704 G 1x 7Kw 7 400 x 758 x 378
FTR- 708 G 2x 7Kw 14 800 x 758 x 378
FTR- 740 G 1x 7Kw 7 400 x 758 x 957
FTR- 780 G 2x 7Kw 14 800 x 758 x 957
FTR- C-704 G 1x 7Kw 7 400 x 758 x 378
FTR- C-708 G 2x 7Kw 14 800 x 758 x 378
FTR- C-740 G 1x 7Kw 7 400 x 758 x 957
FTR- C-780 G 2x 7Kw 14 800 x 758 x 957
FTH 712 G 3X 7kW 21 1200 x 370 x 730
FTR 712 G 3X 7kW 21 1200 x 370 x 730
FTHR 712 G 3X 7kW 21 1200 x 370 x 730
FTHC 712 G 3X 7kW 21 1200 x 370 x 730
FTRC 712 G 3X 7kW 21 1200 x 370 x 730
FTHRC 712 G 3X 7kW 21 1200 x 370 x 730
FTH 7012 G 3X 7kW 21 1200 x 960 x 730
FTR 7012 G 3X 7kW 21 1200 x 960 x 730
FTHR 7012 G 3X 7kW 21 1200 x 960 x 730
FTHC 7012 G 3X 7kW 21 1200 x 960 x 730
FTRC 7012 G 3X 7kW 21 1200 x 960 x 730
FTHRC 7012 G 3X 7kW 21 1200 x 960 x 730

5
PLACEMENT
The device must be instalated in well ventilated room what is necessary for regulation of the function of the
device (technician must go by valid standard (EN....). If the device is situated close to the wall or if it is in
contact with the furniture walls, these walls must resist the temperatures ranging to 90°C. Instalation, setting,
putting into operation must be done by qualifi ed person who is competent for this and according to the valid
standards.
Wrap up the device and check whether it was not damaged during transport. Settle the device on horizontal
surface (max imbalance 2°).Settle the device under the fumehood to eliminate water steam and bad smell.
The device can be instalated separately or in a set with devices of our production. Min. distance 10 cm
from other subjects must be kept.It is also necessary to prevent our product from contact with combustible
materials. In this case you must make corresponding changes to secure heat izolation of combustible parts.
Safety measures from the standpoint of the fi re protection according to EN 061008čl. 21:
PACKING AND DEVICE CHECK
The device leaves our stocks properly packed with appropriate symbols and labels. There are also appropriate
instructions for use. In case the packing shows bad handling or damage, it must be reclaimed at transporter
immediately by writing and signing of a damage protocol.
Important notice:
-This product is only intended for use inside.
Never use the appliance if it has a damaged supply cable or plug, if it is not working correctly, has fallen to
the ground and been damaged or fallen into water. In such cases take the appliance to a professional service
in order to verify that it is safe and works correctly.
• only for proff esional use
• this instructing guide must be read properly and carefully because it contains important information about
safety elements, installation, use
• these recommendations refer to this product
• this product corresponds with valid standards
• this guide must be properly deposited for future use
• keep the children away from manipulation with the product
• when selling or moving the product to another place it is necessary top make yourself sure that the staff
or the professional service has got acquainted with control and installation instructions from enclosed guide
• only authorised person can operate the product
• it can not be switched on without supervision
• we recommend to have the product checked by professional service min. once a year
• only original spare parts can be used for repairs
• the product can not be cleaned by the water jet or pressure shower
• by damage or break down disconnect all the feeders (water, gas, electricity) and call professional service
• producer refuses any responsibility in case of damages caused by wrong installation, by disobserving of
above mentioned recommendations or by other use etc.
5

6
TECHNICAL INSTRUCTIONS FOR INSTALATION AND REGULATION
Important:
The manufacturer does not provide warranty for defects caused by improper use, failure to instructions
contained in the attached instructions for use and mistreatment of the appliances.
Installation, adjustment and repair of appliances for kitchens, as well as their removal because of possible
damage to the gas can be carried out only under a maintenance contract, this contract may be signed with an
authorized dealer, and must be complied with regulations and technical standards and regulations regarding
the installation, power supply, gas connection and health & safety system.
These instructions are intended for the qualifi ed technician who must perform the installation, put it into
operation and test the appliance.
Any activity as settings, placement, rebalancing etc, must be made only when is device disconnected from
electricity. If it is necessary to have the device connected to the electricity you must keep the highest attention
to avoid any injuries.
DEVICE INSTALATION
Instalation, setting, rebuilding for another gas type, putting into operation must be done by qualifi ed person
whois competent for this and according to the valid standards. The device can be instalated in good ventilated
room. When it is possible place the device under the fumehood to suck off the products of combustion. Air
needy to the burning is 2m/3/h/kW ot the performance of the instaled device. The device can be instalated
separately or in a set with devices of our production. Min. distance 10 cm from other subjects must be kept.It
is also necessary to prevent our product from contact with combustible materials. In this case you must make
corresponding changes to secure heat izolation of combustible parts (for example:place between the device
and combustible material azbestos plate).
6

7
SAFETY MEASURES FROM THE STANDPOINT OF THE FIRE
PROTECTION ACCORDING TO EN 061008 ČL. 21
• only adults can operate the device
• device must be safely used in common surroundings according to EN 332000-4-462; EN 332000-4-42. You
must switch the gas device off under the circumstances leading: to the danger of the temporary rise of the
combustion gas or steam or during works when there is a big possibilityof rise ot the temporary fi re danger
or explosion (for example: to stick linoleum, PVC etc.).
• before you start to instal the device you must get the licence for connection to the gas feeder from the
gasworks
• device must be placed so as to stand or hang on the noncombustible surface which is on each side 10
cm larger than the device. No subjects from combustible materials can be placed directly on the device
or in distance which is shorter than safety distance (the shortestdistance is 50 cm in the direction of the
heat emission and 10 cm in other directions).- safety distances from various materials of diff erent degree of
combustion and information about the degree of comb. of common building materials - see chart:
Chart:
Combustion degree of building materials classifi ed according to the combustion degree of materials and
products (EN 730823)
A noncombustible granit, sandstone, concretes,bricks, ceramic wallfacing tiles, plaster
B uneasily combustible akumine, heraklite, lihnos, itavere
C1 hardly combustible leafy wood, plywood, sirkoklit, rare paper formica
C2 middle combustible fi breboards, solodure, cork boards, rubber,fl oor-coverings
C3 easily combustible wood-fi breboards, polystyrene,polyurethane, PVC
Devices must be instalated in a safe way. When instaling you must respect corresponding project, safety and
hygienic orders according to:
• EN 061008 fi re protection of local devices and sources of heat
• EN 332000 (33 2000-4-482; 33 2000-4-42) surrounding for electric devices ČSN EN 1775 Gas supplying
• Gas fi ttings in the buildings - the highest operational pressure < 5 bar - operation demands
• § 10 law nr. 185/2001 Sb. about waste

8
PIPE FOR GAS CONNECTION
It must fi rst determine if the appliance is made for the same type of gas that will be used and thus conforms
to the indications on the label the type of gas to be used.
The conversion of gas pan to another type of gas you need to check if it corresponds to the type of gas
bearing, which is recommended in this guide.
Connecting the appliance to the gas distribution must be towable to a steel or copper tube complying with
applicable national requirements. This must be controlled on regular basis and changed if needed. Every
appliance must be equipped with shut-off valve and quick shut-off valve. Quick shut-off valve must be freely
accessible and within reach of the device. After installation, is necessary to check whether there is a gas leak.
To fi nd a gas leak you can use soapy water or spray for gas leak detection.
Do not use corrosive substances!! All our appliances are carefully controlled. Gas type, pressure and of the
categories listed named on the technical information plate.
Liquid gas connection:
Pressure for liquid gas connection must be 28 or 30 mbar for propane/butane and 37 mbar for propane. It
is necessary to check the technical label ,gauge the pressure and check the parameters of the nozzle is
installed with the required parameters of the nozzle according to the manufacturer‘s. If the pressure is lower
than 25mbar or higher than 37 mbar, THE APPLIANCE SHALL NOT TO BE CONNECTED.
Gas Connection:
Pressure for methane connection must be 18 or 20 mbar. It is necessary to check the technical label ,gauge
the pressure and check the parameters of the nozzle is installed with the required parameters of the nozzle
according to the manufacturer‘s. If the gas pressure is lower than 15mbar or higher than 22,5 mbar, THE
APPLIANCE SHALL NOT TO BE CONNECTED.
8

9
Outlet hood with natural extraction (A). Flue gas provides a natural chimney draft.
Outlet hood without natural extraction. Flue gas is secured by a fan (D) (forced extraction). In this
case, it is necessary to secure the connection with a gas feeder (B) to turn off the gas supply in case
of failure.
NATURAL EXTRACTION FORCED EXTRACTION
CHIMNEY DESIGN FOR ANAPPLIANCE –TYPEA

10
10
CHECK THE GAS TYPE THE DEVICE IS ADJUSTED FOR
Our appliances are certifi ed and regulated the natural gas (see technical plate). Conversion or adaptation to
a diff erent type of gas must be performed by authorized personnel. Nozzles for diff erent types of gas are in a
bag provided with the gas cooker and are marked in hundredths of mm (table of technical data pipes).
Nozzle replacement and pressure adjustment
Proceed as follows when replacing the main burner nozzle:
1) remove the control buttons from the front panel (fi g.1, note 1)
2) disassemble the front panel (fi g.1, note 2)
3) According to picture (fi g. 2) unscrew the nozzle from the main burner and replace with nozzles according
to table „TECHNICAL DATA“
4) Adjust the air intake for the relevant gas according to table „TECHNICAL DATA“
Adjust the pilot burner by loosening the safety nut (pct.3, note 1) with a spanner, then unscrew the pilot burner
nozzle and replace with a nozzle for the relevant gas according to the table. Tighten the nozzle cover with a
spanner.
Important:
After what was done adjusting the appliance to another type of gas, it is necessary to change the gas
indicated on the technical plate located in a visible location on the back of the device.