Riva PLUS COMBI Instrucciones de instalación

Riva
BOILER INSTALLATION, OPERATION
INSTRUCTIONS
Riva
PLUS COMBI
WALL HUNG GAS BOILER FOR
CENTRAL HEATING SUPPLY
Please Read Instructions Carefully
Save for Future Reference
— Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone. Fol-
low the gas supplier’s instructions.
• If you can not reach your gas supplier call the fire department.
— Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property dam-
age, personal injury or loss of life.
Quincy Hydronic Technology, Inc.
3560 Lafayette Road
Bldg. 2, Unit A
Portsmouth, NH 03801
Phone: 603-334-6400
Fax: 603-334-6401

2 RIVA PLUS COMBI MANUAL
Dear Customer:
Thank you for buying a Biasi Riva Plus Combi.
The Riva Plus Combi is a high efficiency condensing, wall mounted gas boiler which provides
central heat supply water.
We realize that it is not possible to answer all questions about the Riva Plus Combi system in
this manual. Reading this installation manual does not make the reader an expert in all aspects
of installation and operation, and does not replace the need for a qualified, licensed heating
contractor. We urge you to contact your installing contractor or distributor if you are in question
about any aspect of your boiler’s performance. Our main concern is that you are satisfied with
your boiler and its performance. We require that your contractor complete efficiency tests using
instruments.
The external controls and accessories listed in this manual (excluding those supplied inside
the boiler) are intended to serve as guidelines rather than specific recommendations. We re-
alize that other makes and models of such devices are available and can be used as suc-
cessfully as those we specify. The installing contractor is the best judge of a system’s specific
requirements, as well as the local availability of certain makes and models of controls and
accessories. The preceding does not apply, however, to the equipment that comes with every
boiler, such as the overheat control and pressure relief valves. The installation of the spe-
cific devices supplied with every boiler is absolutely necessary to the safe operation of
the boiler and protection of the heating system.
All BIASI wall hung boilers are built in accordance with the ASME boiler and pressure vessel
code, and bear the “H” stamp. The Entire range of applications for the Riva Plus Combi has
been tested to standard CSA 4.9 and is CSA compliant.
This Riva Plus Combi has a 2 year warranty, a copy of which is provided with the boiler. Please
be sure to return the warranty registration card as the warranty will be void without your boiler’s
serial numbers (located on the ratings label affixed to the boiler), date of installation and the
name of your installer being on record in our files.
Thank you for purchasing our Riva Plus Combi. If you have questions or comments, please
don’t hesitate to contact us immediately. Our goal is 100% customer satisfaction.
QHT inc.

RIVA PLUS COMBI MANUAL 3
Table of Contents
Section Title Section Number Page Number
Warnings - 5-6
Important Information - 7
General Information 1 8
Technical Information (M135.30CM) 2 8-9
Parts List 3 10
Internal Piping and Parts List 4 11
Electric Diagrams 5 12
Sequence of operation 5.1 13
Installation Location 6 14
Exhaust Pipe Location 7 15
Mounting Bracket 8 16
Venting 9 17-24
Restrictor Sizing 9.1 19
Fitting the Flue System 9.2 19
Choice of Flue 9.3 20-23
Pipe Connections 10 24
Gas Pipe Connections 11 25
Electrical Connections/Wiring 12 26-27
Power Connection 12.1 26
Connection to the Electricity Supply 12.2 26
Room Thermostat Connection 12.3 27
Relay Panel Control Connection 12.4 27
Zone Valve Microswitch Connection 12.5 28
Finishing 12.6 28
Circulator Sizing 13 29
Circ. Cap. as a Function of Flow Rate 13.1 29
Expansion Vessel 13.2 29
Piping 14 30-33

4 RIVA PLUS COMBI MANUAL
Table of Contents
Section Title Section Number Page Number
Primary-Secondary with Zone Valves 14.2 32
Manifold Piping with Zone Valves or Circ. 14.3 33
Commissioning 15 34-40
Initial Filling of the System 15.1 34
Lightning the Boiler 15.2 34
Checking the Gas Pres. at the Burner 15.3 35
Adjustment of the Gas Pressure 15.4 36
Checking the Ignition Device 15.5 36
Checking the Burner Ignition 15.6 37
Adjustment of the Useful c.h. Output 15.7 37
Labels Placement 15.8 37
Checking the Flue System and Comb. 15.9 38
Instructing the User 15.10 39
Gas Conversion 16 40
Annual Maintenance 17 41-43
Warnings 17.1 41
Dismantelling the External Panels 17.2 41
Emptying the C.h. System 17.3 41
Emptying the D.h.w.circuit 17.4 42
Cleanig the Burner. 17.5 42
Checking the combustion fan 17.6 42
Checking the Flue 17.7 42
Checking the press. in the exp.vassel 17.8 43
Visual Inspection of Appliance 17.9 43
Gas Pressures and Soundness 17.10 43
Cleanig the primary heat exchanger 17.11 43
Cleanig the domestic hot water exchanger 17.12 43
Condensate trap 17.13 43
Vent Part Spares 18 44-46
Installer Notes 19 47

RIVA PLUS COMBI MANUAL 5
WARNING
Boiler is certified as an indoor appliance. Do not install boiler outdoors or locate where it will
be exposed to freezing temperatures.
— Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your build-
ing.
• Immediately call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you can not reach your gas supplier call the fire department.
— Installation and service must be performed by a qualified installer, ser-
vice agency or the gas supplier.
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property dam-
age, personal injury or loss of life.
DANGER
Caution: Do not store or use flammable materials, chemicals or flammable liquids,
especially gasoline, in the vicinity of this heating appliance.
Caution: Should overheating occur or the gas supply fail to shut off, do not turn
off or disconnect the electrical supply to the pump. Instead, shut off the gas
supply at a location external to the appliance.
Caution: Do not use this boiler if any part has been under water. Immediately
call a qualified service technician to inspect the boiler and to replace any part of
the control system and any gas control which has been under water.

6 RIVA PLUS COMBI MANUAL
WARNING
Any appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of pro-
ducing carbon monoxide (CO). Carbon Monoxide (CO) is a gas which is odorless, colorless
and tasteless but is very toxic. CO is lighter than air and thus may travel throughout the
building.
BRIEF EXPOSURE TO HIGH CONCENTRATIONS OF CO, OR
PROLONGED EXPOSURE TO LESSER AMOUNTS OF CO MAY
RESULT IN CARBON MONOXIDE POISONING. EXPOSURE CAN BE
FATAL AND EXPOSURE TO HIGH CONCENTRATIONS MAY RESULT
IN THE SUDDEN ONSET OF SYMPTOMS INCLUDING
UNCONSCIOUSNESS.
Symptoms of CO poisoning include the following:
dizziness vision problems shortness of breath
headache loss of muscle control unclear thinking
nausea weakness unconsciousness
The symptoms of CO poisoning are often confused with those of influenza, and the highest
incidence of poisoning occurs at the onset of cold weather or during flu season.
A victim may not experience any symptoms, only one symptom, or a few symptoms.
Suspect the presence of carbon monoxide if symptoms tend to disappear when you
leave your home.
The following signs may indicate the presence of carbon monoxide:
• Hot gasses from appliance, venting system pipes or chimney, escaping into the living
space.
• Flames coming out around the appliance.
• Yellow colored flames in the appliance.
• Stale or smelly air.
• The presence of soot or carbon in or around the appliance.
• Very high unexplained humidity inside the building.
If any of the symptoms of CO occur, or if any of the signs of carbon monoxide are
present, VACATE THE PREMISES IMMEDIATELY AND CONTACT A QUALIFIED
HEATING SERVICE COMPANY OR THE GAS COMPANY OR THE FIRE
DEPARTMENT.
ONLY QUALIFIED, LICENSED SERVICE CONTRACTORS SHOULD PERFORM
WORK ON YOUR BIASI RIVA COMBI BOILER.

RIVA PLUS COMBI MANUAL 7
IMPORTANT INFORMATION
Please read this page carefully.
• ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL,
STATE AND LOCAL PLUMBING, HEATING AND ELECTRICAL CODES
AND ORDINANCES, AS WELL AS THE REGULATIONS OF THE SERVING
ELECTRICAL, WATER AND GAS UTILITIES.
• All systems should be designed by competent contractors, and only persons
knowledgeable in the layout and installation of heating systems should attempt
the installation of any boiler. It is the responsibility of the installing contractor
to see that all controls are correctly installed and operating properly when the
installation is completed.
• This boiler is intended for use, only with propane or natural gas. All flammable
liquids (especially gasoline), chemicals, rags, paper, wood scraps, debris, etc.,
should be kept away from the boiler at all times. Keep the boiler area clean and
free of all fire hazards.
• Please read the literature and warranties supplied by the manufacturers of the
various accessory equipment. This equipment is warranted by the respective
manufacturers, not by Quincy Hydronic Technologies, Inc. Each piece of
equipment must be installed and used according to the recommendations of
the manufacturer.
Codes and Regulations:
Installation of the boiler and related equipment must conform to national, state and
local regulating agencies and codes applicable to the installation of the equipment. In
the absence of local requirements, the following codes apply:
A. ANSI/NFPA - #70 National Electric Code
B. ANSI/NFPA - #211 Chimneys and Vents
C. ANSI/NFPA - #Z223.1 National Fuel Gas Code
C. ANSI/NFPA - Domestic Gas Conversion Burner
D. CAN/CGA - B149 Installation Codes
E. ANSI/ASME - CSD-1
The above codes are available from:
National Fire Protection Association (NFPA) CSA International
Battery March Park 8501 E. Pleasant Valley Road
Quincy, Massachusetts, 02269 Cleveland, OH 44134-5575
http://www.nfpa.org http://www.csa-international.org

8 RIVA PLUS COMBI MANUAL
1. General Information
2. Technical Information (M135.30CM)
The Riva Plus Combi is a high efficiency condensing, wall mounted gas boiler which provides
central heat. The boiler features a gas valve which modulates the energy input from 49,476
BTU/h to 116,008 BTU/h. The boiler is shipped fully assembled with the components listed on
page 11. All units are pressure and combustion tested at the factory prior to shipping.
Key Features:
• Wall mountable - saving valuable floor
space.
• Several flue options available
• Electronic spark ignition
• Safety flow switch - positioned on the
main circuit, which monitors the flow and
protects the main heat exchanger from
thermal shock should there be a lack of
water in the system.
• Frost protection - contains an integral frost
protection system to prevent frost dam-
age which can occur in areas susceptible
to very cold weather conditions.
• Boiler operation recognition system -
should the boiler not be used for longer
than 24 hours, it then performs a con-
trolled system test to ensuring the motor-
ized components within the boiler do not
become inoperable due to lack of use.
• Gas valve modulation - the gas input
modulates based off central heating tem-
perature to within ± 2 ºF
• Diagnostic information system equipped
with three LED diagnostic lights for quick
error assessment.
GENERAL
Height in 31.6
Width in 15.7
Depth in 13.8
Weight lb 109.5
ELECTRICAL
Voltage V 120
Frequency Hz 60
Current A 1.6
Power consumption W 180
INJECTORS No. Size
Natural 14 130
Propane 14 89
CENTRAL HEATING
Maximum working temp. °F 185
Temp. Regulation range* °F 100-176
Maximum pressure psi 30.0
Minimum pressure psi 4.35
Max head loss (at 4.4 GPM) ft 8.25
*At the minimum useful output

RIVA PLUS COMBI MANUAL 9
2. Technical Information Cont.
ENERGY CAPACITY
Nominal heat input
(0/2000ft) MBH 116.0
Nominal heat input
(2000/4500ft) MBH 110.2
Minimum heat input MBH 49.5
Maximum useful output
(0/2000ft) MBH 102.0
Maximum useful output
(2000/4500ft) MBH 97.2
Minimum useful output MBH 41.6
GAS SUPPLY PRESSURE
Gas Normal Min Max
Natural inwc 7.0 3.5 10.5
Propane inwc 11.0 8.0 13.0
GAS PRESSURE AT BURNER
Gas Min Max Ignition
Natural inwc 1.0 4.8 2.4
Propane inwc 2.0 10.3 5.2
FLUE DESIGN
Minimum Venturi pressure inwc 0.64
Flue pipe diameter
Coaxial in 2.25/4
3.25/5
Twin split pipes in 3.25/3.25
Nominal heat flow rate
(0/2000ft) MBH 116.0
Nominal heat flow rate
(2000/4500ft) MBH 110.2
Min Exhaust temperature °F 140
Max Exhaust temperature °F 180
GAS FLOW RATE
Gas Min Max
Natural ft³/h 48.7 115.1
Propane lb/h 2.2 5.2
CLEARANCE TO COMBUSTIBLES
Front in 18
Back in 0
Top in 8
Sides in 2
Bottom in 8
Flue pipe enclosed in 2
Flue pipe free air in 0
Hot water pipes in 1”
FLUE GAS FIGURES
Gas Min Max
CO22.5% 6.3%
O216.5% 9.7%
DOMESTIC HOT WATER
Maximum temperature °F 131
Minimum temperature °F 95
Maximum pressure psi 145
Minimum pressure psi 4.35
D.h.w. ΔT 45 F (25 C) gpm 4.5
D.h.w. ΔT 54 F (30 C) gpm 3.8
D.h.w. ΔT 63 F (35 C) gpm 3.2
D.h.w. ΔT 72 F (40 C gpm 2.8

10 RIVA PLUS COMBI MANUAL
3. Parts List
Primary Components:
1 Pump
2. Pump vent plug
3. Automatic air purger valve
4. Modulation gas valve
5. Flame-detecting electrode
6. Ignition electrodes
7. Burner
8. Combustion chamber
9. Primary heat exchanger
10. Fan
11. Air pressure switch
12. Air switch pres. Test points
13. Safety thermostat
14. Modulation operator
15. Gas valve outlet pres. Test point
16. Gas valve inlet pres. Test point
17. Central heating expansion vessel
18. Central heating temp. Probe NTC
19. Central heating pressure relief valve
20. Primary circuit flow switch
21. Main circuit drain cock
22. By-pass valve
23. Three-way diverter valve
24. Venturi device
25. Flue outlet pipe
26. Air Intake Pipe
27. Control panel
28. Safety thermostat probe
29. Pressure reducing automatic fill valve
30. Backflow preventer
31. Gas supply line cock
32. Water supply inlet cock
33. Condensate trap
34. Condensing heat exchanger
35. Flue termostat
36. D.h.w heat exchanger
37. D.h.w flow switch
38. Domestic water circuit filter
39. D.h.w flow limiter
40. Domestic hot water temp.probe NTC
41. Domestic cold water inlet valve
42. D.h.w. outlet pipe
Tabla de contenidos
Otros manuales de Caldera de Riva