Ridder RLD200 Manual de usuario

Product Manual
Ridder LogicDrive RLD200
265110EN - 2017.07 - V03
Ridder Drive Systems
Lorentzstraat 36-38 3846 AX Harderwijk
P.O. Box 360 3840 AJ Harderwijk
The Netherlands
T+31 (0)341 416 854 F+31 (0)341 416 611
Iwww.ridder.com Einfo@ridder.com

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
2
This product manual contains important informaon for installers on how to connect and
commission a Ridder LogicDrive RLD200. All acvies in this respect should be carried out by
qualied and skilled mechanical and / or electrical installers in proper and safe condions.
Table of contents
1.1 LogicDrive RLD200 product manual
1.1 LogicDrive RLD200 product manual ............................................. 2
2.1 LogicDrive RLD200 descripon .................................................3
2.2 LogicDrive RLD200 applicaon .................................................3
2.3 LogicDrive RLD200 technical specicaons .......................................4
2.4 LogicDrive RLD200 dimensions..................................................4
2.5 LogicDrive RLD200 winch belt pull force for venlaon systems ...................... 5
2.6 LogicDrive RLD200 packaging contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.1 LogicDrive RLD200 mounng posions .......................................... 6
3.2 Mounng the LogicDrive RLD200 ...............................................7
3.3 Mounng the belt drum and winch belt .........................................8
3.4 Pre-winding the winch belt onto the belt drum ....................................9
3.5 Mounng the sprocket ........................................................9
4.1 Connecon and operaon - abbreviaons ....................................... 10
4.2 Connecng the control components and switch materials, and cable lengths .......... 10
4.3 LogicDrive RLD200 wiring diagram and operang elements ........................11
4.4 LogicDrive RLD200 rotaonal direcon, and end and emergency posions ............12
5.1 Condions and criteria for teaching in the LogicDrive RLD200 . . . . . . . . . . . . . . . . . . . . . . . 13
5.2 Operang the LogicDrive RLD200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.3 LogicDrive RLD200 status LEDs ................................................15
5.4 Control signal of climate controller and emergency posion ........................15
6.1 Teaching in the LogicDrive RLD200 - Programming the end posions .................16
6.2 Teaching in the LogicDrive RLD200 - Programming an emergency posion ............18
6.3 Teaching in the LogicDrive RLD200 - Erasing an end posion ........................19
6.4 Teaching in the LogicDrive RLD200 - Erasing the emergency posion .................20
7.1 LogicDrive RLD200 alarm contact .............................................. 21
8.1 LogicDrive RLD200 blink codes of status LEDs .................................... 21
9.1 LogicDrive RLD200 maintenance ...............................................24
10.1 LogicDrive RLD200 troubleshoong ............................................24
10.2 Technical Support ...........................................................25
10.3 Environment ...............................................................25
11.1 LogicDrive RLD200 accessories ................................................ 26
12.1 Meaning of warnings in this product manual ..................................... 27

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
3
The LogicDrive RLD200 is a maintenance-free drive unit for
accurately and awlessly opening and closing air inlet aps,
air valves and venlaon curtains in livestock houses.
The RLD200 features a sleek housing with a high protecon
class of IP65. This not only makes the RLD200 resistant
to water and dust, but also easy to clean.
The RLD200 is equipped with a self-locking worm wheel
transmission which ensures that the drive sha is braked when the drive unit stops moving. The
matching gear and worm wheel transmissions mean the drive unit runs very quietly. The RLD200
is available with a one-sided or two-sided drive sha for mounng one or more belt drums or
sprockets. The RLD200 is durable and has virtually no duty cycle restricon.
The RLD200 features a 24 V DC stepper motor with intelligent motor control. Using a 0-10 V control
signal, the RLD200 can be posioned extremely accurately. The revoluon range of the RLD200 drive
unit is electronically adjustable from 0.25 to 100 revoluons of the drive sha. The integrated motor
control unit of the RLD200 protects the drive unit against overloading and adjusts it to a taught-in
posion in the event that the control signal is lost (requires emergency power supply). The RLD200
is equipped with a contact to transmit alarm signals.
The RLD200 drive unit can be controlled and powered by the Ridder
LogicControl RLC100 control units (or equivalent) and Ridder
LogicPower RLP200 emergency power supply (or equivalent).
This allows the RLD200 to be adjusted to an emergency posion
should a power failure occur.
The standard RLD200 is nished with a graphite grey powder coang.
The LogicDrive RLD200 drive units are designed to adjust the posions of air inlet aps, air valves
and venlaon curtains in livestock houses and crop storage buildings.
Other applicaons require permission by Ridder Drive Systems.
In addion, the following condions apply when using the LogicDrive RLD200:
● The construcon of the RLD200 may not be modied or changed.
● The applicable regulaons and guidelines (e.g. CE) must be observed.
● The RLD200 may not be used to li or move people.
2.2 LogicDrive RLD200 applicaon
2.1 LogicDrive RLD200 descripon

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
4
2.4 LogicDrive RLD200 dimensions
2.3 Technical specicaons LogicDrive RLD200
Mechanical
Torque 200 Nm
Speed 1 rpm
Winch belt speed 15-22 cm/min
Winch belt length 1 m | 2 m
Rotaonal range between end posions 0,25-100 rev
Drive unit Self-locking
Dimensions (WxHxD) 110 mm x 150 mm x 230 mm
Weight 20 - 23 kg
Electrical
Supply voltage 24 V DC (± 10 %)
Maximum current 4 A
Power 96 W
Alarm contact 24 V AC/DC, 1 A
Protecon Mechanical and thermal overload
Control
Control signal 0-10 V DC / 10-0 V DC
Control signal dierence (A - B) > 2 V DC
Emergency posion control
Lower value of control signal > 1 V DC
Acvaon signal < Lower value of control signal x 0.5 V DC
Emergency posion (C) Freely adjustable
between or to one of the end posions (A, B)
Environment
Protecon class IP65
Ambient temperature 0-40 °C (32-104 °F)

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
5
2.5 LogicDrive RLD200 winch belt pull force for venlaon systems
Winch belt forces depend on:
● Type of LogicDrive RLD200 (one-or two-sided output drive sha, single or double winch strap).
● The required winding length of the winch belt.
Winding length limitaons:
● Pre-winding the winch belt around the drum (± 100 mm, see also §3.4).
● Winding capacity of drum (± 2000 mm).
Graph lines:
1. RLD200 winch belt pull force per winch belt: One winch drum with a single wing belt
(graph line ①).
2. RLD200 winch belt pull force per winch belt: One winch drum winch with a double winch belt
(graph line ②).
Belt forces only applicable for opening and closing air inlets and
valves! Forces not allowed for liing or hoisng objects or people!

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
6
Please observe the following mounng posions when installing the LogicDrive RLD200.
3.1 LogicDrive RLD200 mounng posions
2.6 LogicDrive RLD200 packaging contents
Each LogicDrive RLD200 unit is packaged in a box together with its accessories. The following table
shows which items are supplied in each box.
315° < α < 45° 45° ≤ α ≤ 315°
45°
315°
90°
270°
180°
α=0°
315° < α < 45° 45° ≤ α ≤ 315°
45°
315°
90°
270°
180°
α=0°

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
7
3.2 Mounng the LogicDrive RLD200
1
Please ensure that the RLD200 is mounted securely, so
that the building structure can suciently absorb the
forces applied.
2
When mounng the RLD200, ensure that the motor
cover remains accessible so you will have no problems
connecng and teaching in the RLD200.
3
To drill the mounng holes, a drilling template has been
included. Use the drilling template to mark the holes onto
the wall or structure.
If you do not wish to use the template, mark the holes as
shown opposite.
4a
Mounng the unit to a wall (blind holes).
● Drill holes for wedge bolts or sleeves.
● Secure the unit using the following fasteners:
① M8 x 75 wedge bolt (with washer, spring washer
and nut).
② M8 wedge sleeve (with ③).
③ M8 x 65 hexagon bolt (with washer and spring
washer).
4b
Mounng the unit to a steel structure (through holes).
● Drill ø 8.5 mm holes.
● M8 x 30 hexagon screw (4x).
● M8 self-locking nut M8 (4x).
● M8 body washer (8x).
Mount the LogicDrive RLD200 according to the following instrucons and in a mounng posion as
described in §3.1.

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
8
Mount the belt drum and winch belt (or belts) for the RLD200 as follows:
3.3 Mounng the belt drum and winch belt

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
9
3.4 Pre-winding the winch belt onto the belt drum
To safely use the belt drum and winch belt of the LogicDrive RLD200, it is necessary to rst pre-wind
the belt onto the drum:
Not pre-winding the winch belt may result
in injury at high belt or drum loads.
3.5 Mounng the sprocket
Mount the sprocket for the RLD200 as follows:
Belt drum
with a single belt:
●At least ¼ revoluon.
Belt drum
with a double belt:
●At least ¼ revoluon.

Ridder Drive Systems T+31 (0)341 416 854 F+31 (0)341 416 611 I www.ridder.com
10
4.1 Connecon and operaon - abbreviaons
The data in the table below allows you to determine the required conductor diameter, based on the
cable length and supply voltage.
4.2 Connecng the control components and switch materials, and cable lengths
Symbol Descripon
RLD200
AIN 0-10 V DC Control signal
C Emergency Posion
DIR A | DIR B Push buon for rotaonal direcon A | B
GND Ground (earth) terminal
LED A | LED B LED for rotaonal direcon A | B (Green, control board X1)
PROG Programming buon
RELAY Alarm contact terminal (control board X1)
RUN LED Status LED for motor board X2 (green)
S1 DIP Switch (control board X1)
X1 | X2 Control board | Motor board
M1 - RLC100
1 - Sgn 0-10 V DC control signal from climate controller
2 - Gnd Return wire of control signal from climate controller
3 - Scr Shield of control cable
4 - AL Alarm signal from LogicDrive
5 - AL Return wire of alarm signal from LogicDrive
6 - Sgn 0-10 V DC control signal to LogicDrive
7 - Gnd Return wire of control signal to LogicDrive
8 - Scr Shield of alarm and control signal cables
9 - 24 V 24 V DC LogicDrive power supply
10 - Gnd Return wire of LogicDrive power supply
Please use only suitable control components and switch materials.
Make sure you are using the correct equipment by consulng the
informaon of the control components and switch materials.
The LogicDrive requires a supply voltage of 24 VDC ± 10 %.
Cable Voltage Min. conductor diameter Max. cable length at 24 V DC
Power cable 24 VDC 1.5 mm² 30 m
2.5 mm² 50 m
Control cable 0-10 VDC 0.75 mm²
Note: If longer cable lengths are required, you can consider compensang for the voltage loss by
increasing the supply voltage of the LogicDrive RLD200. A conductor diameter of 1.5 mm² requires a
1 V DC increase per 10m of cable length and a diameter of 2.5 mm² requires a 1 V DC increase per
15 m of cable length (both in addion to the relevant value specied in the table).
Este manual sirve para los siguientes modelos
10
Tabla de contenidos
Otros manuales de Accionamiento de CC de Ridder
Manuales populares de Accionamiento de CC de otras marcas

Vincent Associates
Vincent Associates UNIBLITZ ED12DSS Manual de usuario

EKSMA OPTICS
EKSMA OPTICS DQ-100-4 Manual de lista de piezas

Chamberlain Garog
Chamberlain Garog D Series Manual de usuario

Parker
Parker PDS Series Manual de usuario

Festo
Festo DGC G Series Guía de configuración

Binks
Binks QS-5012-1-CE Manual de usuario

ABB
ABB RSYC-01 Manual de usuario

Rockwell Automation
Rockwell Automation PowerFlex 700S Manual del propietario

WEG
WEG DeviceNet CFW500 Manual de usuario

Siemens
Siemens SINAMICS G Hoja de datos

Siemens
Siemens SINAMICS SM150 6SL3815-7NP41-0AA1 Instrucciones de funcionamiento

SOMFY
SOMFY JR RU 30 Manual de usuario