http: www.repeatit.se support trinity
Before proceeding with the installation verify that the equipment works on the ground. Power up
both units and put them between your computer and network access, you should have full
communication within a few minutes of powering up the units. (If the units have no internal antenna
make sure you place the antenna connectors directly opposite each other.)
The units are pre-configured and paired from factory with the following parameters.
Master
MasterMaster
Master
Client
ClientClient
Client
IP Address
IP AddressIP Address
IP Address
10.0.0.1 10.0.0.2
Username
UsernameUsername
Username
admin admin
Password
PasswordPassword
Password
public public
Installing the link
Installing the linkInstalling the link
Installing the link
•Mount the first unit, point it towards the site of the second unit. Power it up and make sure
the Power LED is lit and the status LED blinks slowly.
•Mount the second unit. Power it up and adjust it for best signal using the status LED.
•Adjust the first unit for best signal using the Status LED.
•Make sure all cables are secured and connect the link to the network.
•Configure the distance parameters at the master unit to reflect the correct distance
between the units.
Note
NoteNote
Note Make sure that the polarization on both units are in the same direction. Unaligned
polarization will significantly reduce the signal strength.
Package contents
Package contentsPackage contents
Package contents
Trinity
TrinityTrinity
Trinity-
--
-116M M Plus
116M M Plus116M M Plus
116M M Plus
2 Trinity-116M 116M Plus units with an integrated 16 dBi antenna.
2 Mounting kits.
2 PoE with power adapter for your local region (third party supplier)
Note
Note Note
Note PoE is not included in deliveries to Brazil
Warning
WarningWarning
Warning
This product transmits information using microwave radio signals.
nstallation of fixed outdoor radio links should only be performed by a qualified
and trained technician familiar with local radio, electric and safety regulations.

How to access the units web interface
How to access the units web interfaceHow to access the units web interface
How to access the units web interface
The unit does not have a DHCP server and will not provide any IP address to your PC when you
connect the Ethernet cable. To be able to access the unit, your computer needs to be configured
with a static IP address that is within the same subnet as the IP address of the unit.
To change the IP address of your network card you need to open the configuration utility for your
network card. For information on how to do that please consult you operating system manual.
The default IP settings of the units are:
IP Address
IP AddressIP Address
IP Address
Netmask
NetmaskNetmask
Netmask
Master Unit
Master UnitMaster Unit
Master Unit
10.0.0.1 255.0.0.0
Client Unit
Client UnitClient Unit
Client Unit
10.0.0.2 255.0.0.0
Recommended configuration of your network card is:
IP Address
IP AddressIP Address
IP Address
Netmask
NetmaskNetmask
Netmask
PC card
PC cardPC card
PC card
10.0.0.3 255.0.0.0
You do not need to have a gateway address to configure the unit when you are connected directly to
it.
If you want the units to be accessible within your normal subnet you will have to reconfigure the IP
addresses of the units. Remember that after changing the IP address of the unit you will not be able
to access it again until you have reconfigured your network card to be in the same subnet as you
configured in the unit.
Note
NoteNote
Note Your Trinity link will work as a cable replacement (transparent bridge), therefore you should
never connect both units to the same switch or Ethernet segment. Doing so will cause an infinite
forwarding loop which severely will disrupt normal traffic on your network.
Repeatit AB Tel: +46 8 570 106 66
Hamngatan 33 Fax: +46 8 570 106 67
Sweden www.repeatit.se
Warning
WarningWarning
Warning
At all times, it is the customers responsibility to ensure that an
outdoor antenna
installation complies with local radio, electric and safety regulations. f you are not certain
about the regulations that apply in your country, consult your regulatory agency or a local
Repeatit sales partner.
The customer must verify that:
•The installation is performed by a qualified technician.
•The antenna installer is aware of local regulations and limits, including, but not limited
to, allowed frequency spectrum and maximum E RP limits.
•The final installation complies with local radio, electric and safety regulations,
including, but not limited to allowed frequency and maximum E RP limit.
•Repeatit AB and its resellers or distributors are not liable for any damage or violation of
government regulations that may arise from failing to comply with these guidelines
Este manual sirve para los siguientes modelos
1
Tabla de contenidos