2
RemVu2
Contents
Introduction ......................................................................3
Features...........................................................................4
Introduction ......................................................................7
Installation........................................................................8
Installation Details..........................................................17
Troubleshooting .............................................................20
Specication ..................................................................21
Index ..............................................................................23

RemGuard ©2011
3
RemVu2
Introduction
What is the…
RemVu2 ?
At RemGuard we understand that no two security installations are the same. Unlike many other providers of
remotely monitored CCTV our latest RemVu2 is actually designed, developed and produced in-house. As a
result when the equipment is installed on site it is uniquely congured to meet your individual requirements.
Our highly skilled technical engineers can programme in features so, for example, gates can be opened
automatically or staff can enter a site via a specic route at key times without comprising the security of the
overall site.
The RemVu2 provides advanced CCTV features within a highly scalable, modular architecture, which when
combined with our BS8418 accredited remote monitoring solution makes the perfect security package for
any residential or commercial business requirement.
The RemVu2 is composed of a video server or VSRV which handles video compression, networking and
transmission, and a communicator or ECOM which handles all alarm inputs, outputs, communication, and
interface to STU.
For further information, please visit the website:
www.remguard.com

RemGuard ©2011
4
RemVu2
Features
• DigitalVideoRecorderwithIntegratedAlarmPanel
• DesignedspecicallyforintegrationwithRemoteVideoReceivingCentres(RVRC)
• 16camerainputswithloopthrough
• 200pps(upto4CIF)withadditionalcodecs
• 1TBofinternalstorage
• 30individualEndofLine(EoL)tamperproofalarmcontacts
• 8normallyopenrelays,2dualchangeoverheavydutyrelays
• Webbasedcongurationallowssystemadjustmentswithouttheneedforsitevisits
• BS8418Compliant
• Programmableentry/exitroutesandtimes,partsetzones
• Remotealarmtransmission
• CantransmitoverADSL,LANor3GConnections
• Remotenetworkaccesstoliveorrecordedimages
• MultiModeRecording-Dynamically-switchableresolution,record-rate&compression(MPEG-4/
JPEG)settingsforplaybackofimages
• TransCoding-HighqualityrecordingwithsimultaneousvideotransmissionusingMPEG4or
JPEGforplayback
• Internalfanfortemperaturecontrol
• Internalbackupbatterycapability

RemGuard ©2011
5
RemVu2
ImportantSafeguards
Read Instructions
Allthesafetyandoperatinginstructionsshouldbereadbeforetheunitisoperated.
Power Sources
Thisunitshouldbeoperatedonlyfromthetypeofpowersourceindicatedonthemanufacturer’slabel.
Servicing
Donotattempttoservicethisunityourselfasopeningorremovingcoversmayexposeyoutodangerous
voltageorotherhazards.
Referallservicingtoqualiedservicepersonnel.
Ventilation
Ensureunitisproperlyventilatedtoprotectfromoverheating.
Allthesafetyandoperatinginstructionsshouldbereadbeforetheunitisoperated.
Topreventreorshockhazard,donotexposethisequipmenttorainormoisture.Thelightningashwith
arrowheadsymbolwithinanequilateraltriangleisintendedtoalerttheuserofthisequipmentthatthereare
dangerousvoltageswithintheenclosurewhichmaybeofsufcientmagnitudetoconstituteariskofelectric
shock.
ThisisaclassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcase
theusermayberequiredtotakeadequatemeasures.
Lightning Strike
Theunithassomein-builtprotectionforlightningstrike,howeveritisrecommendedthatisolation
transformersbettedtothesysteminareaswherelightningisacommonoccurrence.
Regulatory Notes and FCC and DOC Information
(USAandCanadianModelsOnly)
Warning:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,
pursuanttopart15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainst
harmfulinterferencewhentheequipmentisoperatedinacommercialenvironment.Thisequipment
generates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructionmanual,maycauseharmfulinterferencetoradiocommunications.Operationofthis
equipmentinaresidentialareaislikelytocauseharmfulinterferenceinwhichcasetheuserwillberequired
tocorrecttheinterferenceattheirownexpense.
Ifnecessary,theusershouldconsultthedealeroranexperiencedradio/televisiontechnicianforcorrective
action.TheusermayndthefollowingbookletpreparedbytheFederalCommunicationsCommission
helpful:“HowtoIdentifyandResolveRadio-TVInterferenceProblems”.
ThisbookletisavailablefromtheUSGovernmentPrintingOfce,Washington,DC20402,
StockNo.004-000-00345-4.

RemGuard ©2011
6
RemVu2
ThisreminderisprovidedtocalltheCCTVsysteminstaller’sattentiontoArt.820-40oftheNECthat
providesguidelinesforpropergroundingand,inparticular,speciesthatthecablegroundshallbe
connectedtothegroundingsystemofthebuilding,asclosetothepointofcableentryaspractical.
CE Mark
IfthisproductismarkedwiththeCEsymbolitindicatescompliancewithallapplicabledirectives.
Directive89/336/EEC.
A‘DeclarationofConformity’isheldatRemGuardLtd.,
1200DaresburyPark,Daresbury,Cheshire,WA44HS,UK.
Choosing a location for installation
• EnsuretheRemVu2isproperlyventilatedtoprotectfromoverheating.
• Ensurethereisa3cmgaponbothsidesoftheunit.
• Ensuretheunitisnotlocatedanywhereitcouldbesubjecttomechanicalshocks.
• Theunitshouldbelocatedinanareawithlowhumidityandaminimumofdust.Avoidplaceslike
dampbasementsorloftspaces.
• Iftheunitistobeinstalledinaclosedassembly,themaximumoperatingtemperaturemustnot
exceed40°C(104°F).
• Ensurethereisreliableearthingofthemainsoutletwhenttedtosupplyconnections(otherthan
directconnectiontothebranchcircuit).
• Anybranchcircuitsupplyingtheunitmustberatedat15Amps.
• Itisrecommendedthatanuninteruptablepowersourcebeconnectedtotheunitincaseofpower
failure(toensurecontinuousoperationoftheunit).

RemGuard ©2011
7
RemVu2
Introduction
The RemVu2 consists of a video server (VSRV) which handles video compression, networking and
transmission, and a communicator (ECOM) which handles all alarm inputs, outputs, communication and
interface to STU.
The RemVu2 has been designed as a single unit with the communicator board mounted above the video
server board.
All video connections are via the BNC inputs.
The PSU is mounted in the case. Mains power is supplied to the PSU via a cable passed through the gland
in the housing.
An optional 12V battery can be connected to the ying leads using the 1/4” spade sockets.
The 1TB hard drive is connected via SATA to the VSRV board. Power is drawn from the ECOM board.
RearPanelconnections
16 Input model
Video
VID1toVID16 75ΩBNCcompositevideoinputs1Vpk-pk(withloop
throughavailable)
MONA 75ΩBNCcompositemonitoroutput,1Vpk-pk
MON SpotMonitoroutput
Audio
AUD1&2IN RCA(phono)socket,8KHz/16KHz/22KHzsampling75Ωinput
impedance,1Vpk-pk
AUD1&2OUT RCA(phono)socket,linelevel<100Ωoutputimpedance,1Vpk-pk
amplicationrequired
Data
USB 2xUSB2.0connectors
NET1 RJ45Ethernetnetworkconnector,10/100Mb/sEthernetNetwork

RemGuard ©2011
8
RemVu2
Installation
Externalconnections
All connections to the lower board within the enclosure are made via the back panel. The upper board
houses connections to the alarms, relays and STU outputs. It is not necessary to remove the upper board
within the enclosure.
Step 1 - Monitor
USB
NET1 AUDIO AUDIO
OUT
OUT
VID 1MON
B
VID 2 VID 3
A
VID 13VID 8VID 6
VID 4
VID 5 VID 7 VID 9 VID 10 VID 12VID 11 VID 14 VID 15 VID 16
Theunitsupportsamainmonitorvia‘MonA’andaspotmonitorviaBNClabelled‘MonB’.
Step 2 - Connecting Video
USB
NET1 AUDIO AUDIO
OUT
OUT
VID 1MON
B
VID 2 VID 3
A
VID 13VID 8VID 6
VID 4
VID 5 VID 7 VID 9 VID 10 VID 12VID 11 VID 14 VID 15 VID 16
ConnectionsforallvideoinputsareviaBNCconnectors.Connectcamerastothevideoinputs,startingfrom
input 1.
5.12

RemGuard ©2011
9
RemVu2
Step 3 - Wiring the Power Supply
ConnectthePSUmountedinthehousingviatheglandinthehousingtoafusedspurconnection.Tobe
compliantwithwiringregulationsinsomecountries,anAlarm/Securitydeviceshouldbeconnectedtoa
fusedspurandnotawalloutletsocket(checklocalregulationsbeforeinstallation).
Anoptional12voltbatteryshouldbeconnectedtotheyingcableswith¼inchspadesockets.

RemGuard ©2011
10
RemVu2
Step 4 - Connecting to the Network or a PC
USB
NET1 AUDIO AUDIO
OUT
OUT
VID 1MON
B
VID 2
VID 3
A
VID 13VID 8VID 6VID 4 VID 5 VID 7 VID 9 VID 10 VID 12VID 11 VID 14 VID 15 VID 16
OnestandardRJ45connectorisprovidedtoenabletheRemVu2tobeattachedtoanetwork.APatchcable
shouldbeusedtoconnectintoahuborswitch.IfadirectconnectiontoaPCisrequiredthenacrossover
cable should be used.
TheunitsupportsanEthernetRJ-4510/100Mbpsauto-detectingnetworkport.UseaCAT5cabletoconnect
theEthernetRJ-4510/100MbpsconnectionmarkedNET1tothenetwork.
TheunitisnormallyconguredwithastaticIPaddress192.168.0.250.
Step 5 - Connecting Audio
USB
NET1 AUDIO AUDIO
OUT
OUT
VID 1MON
B
VID 2 VID 3
A
VID 13VID 8VID 6VID 4 VID 5 VID 7 VID 9 VID 10 VID 12VID 11 VID 14 VID 15 VID 16
Theunitsupportsaudiooutformessages,thereisalineleveloutputtodriveanexternalamplierandthere
areon-boardspeakerconnections.
TheconnectormarkedAUD1OUTisforaudiomessagestotheamplier.
Theonboardspeakersconnectionsareviaspkr1+andspkr1-connectionsontheterminalblockshownin
theimagebelow