Note:
Use this procedure only in the event that the network primary
controller is missing or otherwise inoperable
06 Association
Association allows Water Sensor to control other Z-Wave device such
as siren, smart switch, etc. The Water Sensor supports two association
groupings.
Group 1 reports the flooding detection, temperature and the battery
level. Group 2 is assigned to send BASIC SET command.
1. The max number of associated nodes of all these 2 groups is 5.
2. Association allows for direct transmission of control command
between devices and takes place without the participation of the
main controller.
07 WAKE-UP
Wake-up-interval:
Available settings: 0-2678400
Default setting: 0, setting via RE.GUARD App: 86400
Defining a time period by which the Water Sensor sends a wake up
notification command frame to communicate with the assigned device,
update parameters, update software, detects battery level.
Wake up interval set to 0 disables the sending wake up notification
command, in such configuration it is needed to manually wake up the
device by pressing the Z-button.
Note:
3600 seconds is the step of wake up interval time, which means Water
Sensor will send wake up notification command by a timeline that is
multiple of 3600 seconds.
Setting examples:
0~3599 = 0 second, the device will not wake up by itself.
3600~7199 = 3600 seconds, the device will wake up every