RCF DXT 9000 Manual de usuario

TABLE OF CONTENTS
INDICE
ENGLISH
SAFETY PRECAUTIONS
DESCRIPTION
FRONT PANEL AND HANDHELD MICROPHONE
INTERNAL BOARD CONNECTIONS
SYSTEM CONNECTIONS
SPECIFICATIONS
ITALIANO
AVVERTENZE PER LA SICUREZZA
DESCRIZIONE
PANNELLO FRONTALE E MICROFONO PALMARE
COLLEGAMENTI ALLA SCHEDA INTERNA DELLA CONSOLLE
COLLEGAMENTI AL SISTEMA
DATI TECNICI
4
5
6
7
9
10
12
13
14
15
17
18
www.acornfiresecurity.com
www.acornfiresecurity.com

4
ENGLISH
IMPORTANT NOTES
Before connecting and using this console, please read this instruction manual carefully and keep
it on hand for future reference. The manual is to be considered an integral part of this product and
must accompany it when changing ownership as a reference for correct installation and use as
well as for the safety precautions. RCF S.p.A. will not assume any responsibility for the incorrect
installation and / or use of this product.
SAFETY PRECAUTIONS
1. According to EN 54-16 standard, paging microphones shall be only accessible by persons
having a specic responsibility for safety and who are trained and authorized to operate in the
following conditions: quiescent, voice alarm, fault warning and disablement.
2. All the precautions, in particular the safety ones, must be read with special attention, as they
provide important information.
3. Make sure all connections have been made correctly before switching all devices on.
Do not connect / disconnect this console when the system is operating.
4. Protect console cables from damage and assure they are positioned where these cannot be
stepped on or crushed by objects.
5. Do not put this console into water (or another liquid), do not throw it.
6. Never attempt to carry out any operations, modications or repairs.
If the console does not work properly, contact your authorized service centre.
7. Should the console emit any strange odour or even smoke, turn the sound system off
immediately and disconnect it.
8. RCF S.p.A. strongly recommends the sound system installation is only made by professional
qualied installers (or specialised rms), who can certify it according to the regulations in force.
The entire audio system must comply with the current standards and regulations regarding
electrical systems.
9. Mechanical and electrical factors need to be considered when installing a professional audio
system (in addition to those which are strictly acoustic, such as sound pressure, angles of
coverage, frequency response, etc.).
10. Do not point the microphone at near loudspeakers, in order to avoid feedback.
11. Hearing loss
Exposure to high sound levels can cause permanent hearing loss. The acoustic pressure level that
leads to hearing loss is different from person to person and depends on the duration of exposure.
To prevent potentially dangerous exposure to high levels of acoustic pressure, anyone who is
exposed to these levels should use adequate protection devices.
When a transducer capable of producing high sound levels is being used, it is necessary to wear
ear plugs or protective earphones.
12. To prevent inductive effects from causing hum, noise and a bad system operating, microphone
cables should not be laid together with other electric cables (mains) and loudspeaker lines.
13. Keep the console far from any excessive heat source.
14. Do not use solvents, alcohol, benzene or other volatile substances for cleaning the external
parts. Just use a dry cloth.
IMPORTANT NOTES
SAFETY PRECAUTIONS
www.acornfiresecurity.com
www.acornfiresecurity.com

5
ENGLISH
DESCRIPTION
IN 9000 is an emergency reman console designed to be interfaced with the RCF DXT
9000 evacuation system, in order to provide an analogue backup solution for emergency
communications, in case of interruption of the main digital connection RCFBUS.
This console is protected by a wall-mounted red metallic box with glass and equipped with
a monitored handheld microphone having a momentary ‘Push-To-Talk’ (PTT) button.
The PTT command is also available as front panel button, together with a VU-meter LED
bar (microphone signal level) and an ‘IN USE’ LED.
IN 9000 needs an external 24 ÷ 48 V dc power supply EN54-4 providing at least 20W
output power. Moreover, a monitored GPI is provided to report any power supply fault.
The audio output can be distributed up to 64 DXT 9000 units and routed to 4 independent
lines selectable on the console front panel.
A dedicated (optional) RCF OT 3500 audio transformer can be installed on each output
line.
MAIN FEATURES
-Monitored reman’s microphone with PTT button.
-The console is protected by a wall-mounted red metallic box with glass.
-Fully analogue connection (in the event of interruption of RCF BUS).
-Output signal can be sent to max. 64 DXT 9000 units over 4 selectable independent
lines.
-2 monitored GPI (‘General Purpose Input’): power supply and DXT 9000 fault.
-1 monitored GPO (‘General Purpose Output’) to report a console fault to DXT 9000.
-Power supply range 24 ÷ 48 V dc (external 20 W power supply required).
-Front panel fault reporting: general, microphone, command port, power supply, power
supply GPI, DXT general, DXT general GPI.
IMPORTANT NOTES
IN 9000 shall be placed in a room with access restricted to authorized
personnel only, within a protected area not subjected to conditions that may
affect its operation, for example: moisture, salt, water inltration, extreme
temperatures, shocks, etc.
It should be placed at a height from the oor that makes it easily accessible.
Also check the suitability of the wall and the components used for attachment (wall plugs,
screws, not supplied by RCF), which must guarantee the system security over time, also
considering, for example, the mechanical vibrations normally generated by transducers.
RCF S.P.A. THANKS YOU FOR PURCHASING THIS PRODUCT, WHICH HAS BEEN
DESIGNED TO GUARANTEE RELIABILITY AND HIGH PERFORMANCES.
WARNING:
Any change made by unauthorized personnel to the product and / or the
system (in which it is installed and congured, including rack cabinet and
wiring) may invalidate the CE marking (certication EN54-16: 2008) and also
the product warranty.
www.acornfiresecurity.com
www.acornfiresecurity.com

6
ENGLISH
1IN USE LED When lit: the console is being used.
2LEVEL LED bar indicating the microphone signal level.
3PTT (‘Push To Talk’) button: push and hold down to turn the microphone on and
page the areas assigned to the output lines A, B, C, D, previously selected by pushing
the respective buttons 4.
4OUTPUT LINES A-B-C-D buttons with LEDs: push to toggle on/off the respective
output lines.
5The rectangles graphically linked to the OUTPUT LINES A, B, C, and D can be used
to add labels aimed at better identifying them.
HANDHELD MICROPHONE
The handheld microphone momentary push button has the same function of the front
panel PTT button 3.
FAULT LEDs
LABEL DESCRIPTION
6GENERAL Console local general fault
7MICROPHONE Console microphone fault
8COMMAND PORT Command port fault (no monitoring 24 V dc)
9POWER SUPPLY External power supply fault (monitored GPI)
10 POWER SUPPLY GPI IN 9000 internal fault on its 'Power Supply Fault' GPI
11 DXT GENERAL DXT 9000 general fault (monitored GPI)
12 DXT GENERAL GPI IN 9000 internal fault on its 'DXT 9000 General Fault' GPI
1
4
5
6
7
8
9
10
11
12
2
3
FRONT PANEL AND HANDHELD MICROPHONE
www.acornfiresecurity.com
www.acornfiresecurity.com

7
ENGLISH
INTERNAL BOARD CONNECTIONS
-Connect the IN 9000 POWER SUPPLY INPUT 13 to the external EN 54-4 power
supply output (24 ÷ 48 V dc, 20 W). Pay attention to its polarity.
-Connect the IN 9000 ‘POWER SUPPLY FAULT’ MONITORED GPI 14 to the external
power supply GPO (for remote fault monitoring).
-Connect a DXT 9000 unit monitored GPO to the IN 9000 ‘DXT 9000 GENERAL
FAULT’ MONITORED GPI 15 .
-Connect the ‘IN 9000 FAULT’ GPO 16 to a DXT 9000 unit monitored GPI (1÷8).
POWER SUPPLY 24V ÷ 48VDC
POWER SUPPLY FAULT (MONITORED GPI)
DXT 9000 GENERAL FAULT (MONITORED GPI)
IN 9000 FAULT (GPO)
LINE A LINE CLINE B
OUTPUT LINES
LINE D
13
14
15
16
17
www.acornfiresecurity.com
www.acornfiresecurity.com

8
ENGLISH
-Connect IN 9000 output lines 17 to FALLBACK inputs of DXT 9000 units, as shown
in the following gure (audio: + hot, – cold, ground; command: CM–, CM+)
Note: if ot 3500 traNsformers are Not required oN the output liNes, the correspoNdiNg
from / to coNtacts shall be shorted (factory settiNg).
-If an OT 3500 transformer is necessary on an output line due to excessive noise,
connect it (pin to pin) as shown in the next gure.
LINE A
LINE A
www.acornfiresecurity.com
www.acornfiresecurity.com

9
ENGLISH
SYSTEM CONNECTIONS
IN 9000 can be connected to several rack cabinets (including DXT 9000 main units
and ampliers), routing its audio output through max. 4 independent lines.
For example, next 2 gures show 2 possible wirings: the former 1is the most
simple one (using only one output line), the latter 2is the most complex one
(using all the 4 output lines).
Of course, any layout in between is possible, depending on installation
requirements.
1 2
www.acornfiresecurity.com
www.acornfiresecurity.com

10
ENGLISH
SPECIFICATIONS
Microphone type:
Mic. polar patter:
Output impedance:
Microphone sensitivity:
Frequency response:
Box dimensions:
Net weight:
dynamic
omnidirectional
500 Ω ± 30% (1 kHz)
– 70 dB ± 3 dB (0 dB=1V/μbar, 1 kHz)
300 Hz ÷ 6 kHz (– 3 dB)
360 x 360 x 129 mm
7 kg
www.acornfiresecurity.com
www.acornfiresecurity.com
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Idiomas:
Otros manuales de Mezclador de música de RCF

RCF
RCF F 6X Guía del usuario

RCF
RCF L-PAD 8C Manual de usuario

RCF
RCF F 6X Manual de usuario

RCF
RCF M 20X Manual de usuario

RCF
RCF AM 1064 Manual de usuario

RCF
RCF F 12XR Manual de usuario

RCF
RCF F 10XR Manual de usuario

RCF
RCF M 18 Manual de usuario

RCF
RCF M 20 Series Manual de usuario

RCF
RCF AX 8042 Manual de usuario