Fig. 1
2.
2.0
2.1
2.2
3.
OPERATING HEATING & HOT WATER
TO SET AND ADJUST BUILT-IN TIMER
MODEL SEE OPPOSITE PAGE 3.
3.0
3.1
Select switch (2) position.
Switch on time clock, adjust room stat and/or
thermostatic radiator valves to high settings.
3.2 Main burner will operate. Temperature output
of central heating can be adjusted by central
heating thermostat (4). The knob can be set
between minimum and maximum
approximately 40
o
C to 85
o
C (1 40F to 1 85F).
While the appliance is being used to provide
domestic hot water, the central heating will not
operate. When hot water is no longer required
the appliance will automatically revert to
central heating and should not noticeably
affect the level of central heating. Adjust
external controls to required settings.
OPERATING DOMESTIC HOT WATER 3.3 TO SHUT DOWN THE APPLIANCE
Select only switch position (1).
Open hot water tap. After about 3 seconds
main burner will always operate.
Temperature of domestic hot water can be
varied by adjusting the water flow rate at the
tap. Domestic thermostat (5) will control
maximum temperature leaving the appliance.
The knob can be set between minimum and
maximum approximately 35
o
C to 65
o
C (49F
to 95F). For maximum temperature of domestic
hot water leave in maximum position.
3.3.1
For short periods, switch to only and turn
off all hot taps. For long periods switch of the
on/off switch (1). If the appliance is to be shut
down for long periods when there is a risk of
freezing, then appliance should be drained.
Similar refilling must be done by a competent
person following approved procedures.
4.
CLEANING OF APPLIANCE OUTER CASING
4.1
Use a clean damp cloth. Do not use any
abrasive cleaners and with a dry cloth lightly
polish to protect painted surfaces.
Control panel and fixtures can be wiped with
damp cloth and dried. Spray polishes must
not be used on control panel surfaces or
switches. Care must be taken in preventing
any liquids entering the appliance.
4.2
CARE OF YOUR APPLIANCE AND SYSTEM
4 2.1
Annual servicing of your appliance is required
to maintain safety and efficiency of its
operation. Therefore it is recommended that
the appliance is serviced at least once a year
and that the whole of the heating system be
checked at the same time by a qualified
installer. If it is known or suspected that a fault
exists on the boiler then it MUST NOT be used
until the fault has been corrected by a
COMPETENT PERSON. It is essential that the
instructions in this booklet are strictly followed
for safe and economic operation of the boiler.
SERVICING SHOULD BE CARRIED OUT BY A
COMPETENT PERSON.
NOTE: An anti-cycling device is fitted to the
heating function. When the boiler reaches
its set maximum temperature it will not
operate on heating for about 3 minutes but
the domestic hot water function will always
operate on demand.