Raritan Crown Head II Manual de usuario

crown head II™
ELECTRIC MARINE TOILET
OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS
Manufactured after June 2002
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING: Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installa-
tion. Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to
equipment, or injury or death to personnel that may result from improper installation or
operation of this product.
WARNING: RISK OF SHOCK OR FIRE - Always use recommended fuse/circuit breaker and wire size.
Motors in this product are “Ignition Protected”. They are not however, explosion-proof as
defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
WARNING: RISK OF FLOODING-Always shut off seacock(s) before leaving the boat unattended.
Whenever possible hose connections should be secured using two stainless steel hose clamps.
Integrity of clamps, hoses and fittings should be checked periodically.
1-800-352-5630
www.raritaneng. com
The Crown Head II is an automatic electric
macerating toilet available in Freshwater or
Sea Water flushing.
Crown Head II Sea Water Model Crown Head II Pressurized Freshwater Model
Four different Flush Control options are
available:
1. Push Button activation - Standard
2. Timed Flush with Push Button - RTC
3. Timed Flush with wall mounted touch
pad-TC*+,*specifyvoltageand+color
4. Momentary Flush with ability to con-
trol intake and discharge seperately -
SWF100

• Push Button Switch (#164000)
Press and hold switch until all waste is cleared
from bowl.
NOTE: Push Button Switch flushing is shown.
Refer to manuals included with Toilet Control
(TC12W), Raritime Solid State Timer with
Solenoid (#RTC), or Flush Control (#SWF100) for
operation Instructions.
• No special toilet paper is required.
• Water should appear in the bowl within ten
seconds of flushing. If not, see troubleshooting
section.
• Hard objects or stringy substances (paper
towels, feminine hygiene products, filter
cigarettes, etc.) must not be thrown into the
toilet as they will cause damage.
• Always shut off seacock(s) before leaving the
boat unattended.
Young children should NOT be left unsupervised
around toilet. Serious injury or death could occur.
WARNING: Children can drown in water
retained in the bowl.
CAUTION: Seat and/or lid could close and
strike child.
OPERATION
2
* Specify Voltage
+ Specify Color

MAINTENANCE
Cleaning Instructions
IMPORTANT: Do not use cleaners that contain
ammonia, ethyl acetate, phosphoric acid or
concentrated chlorine bleach. These will cause
damage to the toilet.
Using C.P. (#1PCP22), a bio-enzymatic toilet bowl
cleaner (available from Raritan Engineering), will
keep the bowl clean and fresh smelling.
Recommend Visual Inspection
✔For leaks at toilet and hose connections
✔Hose clamps
✔Condition of hoses
✔Seacocks
✔Condition of wires and connections
✔In-Line Strainer
Cleaning In-Line Strainer
(Sea Water Models only)
1. Shut off intake seacock.
2. Unscrew strainer bowl.
3. Remove filter.
4. Clean bowl and filter with a clean dry cloth.
5. Clean gasket and gasket contact surfaces
thoroughly.
6. Replace gasket, filter and bowl.
7. Open seacock.
8. Check for leaks.
Clean Gasket
and Gasket
Contact Surfaces
Thoroughly
Unscrew Tighten
Bowl
Filter
MAINTENANCE
3
C.P.

WINTERIZING
IMPORTANT
• Improper winter lay up is a major cause of
marine toilet failure.
• Use only nontoxic antifreeze.
• Flush toilet several times to clear waste from
system.
• Dispose of all antifreeze in accordance with
local and federal regulations.
• Winterize holding tanks, plumbing,
treatment systems (MSD’s), etc.
independently following manufacturer’s
instructions.
Sea Water Model
Parts Required
• 1 1/2" (38mm) I.D. piece of hose,
approximately 3 feet (1m) long
• 3/4" (19mm) I.D. piece of hose, approximately
3 feet (1m) long
• Two buckets
• Nontoxic antifreeze approximately 1 quart
(1 liter)
Steps
1. Close intake and discharge seacocks.
2. Turn off power to unit.
3. Disconnect and drain intake hose, discharge
hose and in-line strainer.
4. Connect short hoses to toilet’s intake and
discharge.
5. Place one bucket under hose connected to
toilet’s discharge.
6. Pour antifreeze in other bucket.
7. Place hose connected to intake pump into
bucket with antifreeze.
8. Turn on power to unit and flush until antifreeze
is removed from toilet.
9. Disconnect power to toilet.
WINTERIZING
4
Nontoxic
antifreeze

Pressurized Fresh Water Model
Parts Required
• 1 1/2" (38mm) I.D. hose, approximately 3 feet
(1m) long
• Two buckets
• Nontoxic antifreeze approximately 1 quart
(1 liter)
Steps
1. Close discharge seacock
2. Shut off intake water at source.
3. Turn off power to unit.
4. Disconnect and drain discharge hose.
5. Disconnect intake hoses from vacuum breaker
and place in one of the buckets.
6. Connect hose to toilet’s discharge and place in
the other bucket.
7. Pour antifreeze in bowl.
8. Turn on power to unit and flush until antifreeze
is removed from toilet and water is drained
from intake lines.
9. Disconnect power to toilet.
10. Reconnect intake hoses to vacuum breaker.
RECOMMISSIONING
1. Using buckets, hoses, and clean fresh water,
flush antifreeze out of system (see Winterizing).
Dispose of antifreeze in accordance with local
and federal regulations.
2. Reconnect intake and discharge hoses and open
both seacocks.
3. Check all connections for leaks with several
test flushes.
SYSTEM START-UP
1. Open seacock(s).
NOTE: Pressurized freshwater models; open water
source valve.
2. Turn on power to toilet.
3. Flush toilet per Operation Instructions.
Check for leaks.
WINTERIZING
5
Nontoxic
antifreeze
Allow water
to drain
into bucket

INSTALLATION
Parts Included
All Toilets
Toilet Bowl (Household or Marine)
Seat and Cover
Discharge pump assembly
Heavy Duty Push Button Switch (#164000)
Mounting pads
Lower Motor Cover
Sea Water Model
Remote Intake Pump
3/4" Hose Barb straight fitting
3/4" Hose Barb - 90° elbow fitting
Plug Fitting
In-Line Strainer with fittings
3/4" Stainless Steel Hose Clamps (2)
Pressurized Freshwater Models
Atmospheric Vacuum Breaker with fittings
Solenoid Valve with fittings
Solenoid Valve Mounting Bracket
Flush Control Options
Toilet Control (#TC*+) wall switch
Raritime Control (#RTC*) times the push button
Flush Control (#SWF100+) independant control
Additional Parts Required
• Four 1/4" (6mm) stainless steel mounting
bolts or lag screws and washers (Sea Water
Models)
• Two 1/4" (6mm) stainless steel mounting bolts
or lag screws and washers (Freshwater Models)
• Four 5/16" (8mm) stainless steel mounting
bolts or lag screws and washers
• 1 1/2" (38mm) I.D. discharge hose
• 3/4" (19mm) I.D. reinforced intake hose
• 3/4" (19mm) and 1 1/2" (38mm) hose clamps
(two for each connection below waterline)
• Wire
• Terminals
INSTALLATION
• Fuse/circuit breaker
Tools Required
• 5/16" nut driver
• Wrench or screw driver (depending on mounting
fastener)
• Bit for drilling mounting surface (depending on
fastener used)
• Wire cutters
• Wire terminal crimpers
• Hose cutters
• Tape measure
6
* Specify Voltage
+ Specify Color

SPECIFICATIONS
Base Depth:
10 7/8"
(27.6cm)
Height:
17 3/8"
(44.1cm)
Household
17" (43.2cm)
Marine
Base Width:
10 1/2"
(26.8cm)
Bowl Width:
14 3/8" (36.6cm) Household
13" (33cm) Marine
Bowl Depth:
19 1/4" (48.9cm) Household
16 3/4" (42.6cm) Marine
Plumbing
Maximum suction of Intake pump
(Maximum height above waterline) 4 Ft. (1.2m) from Intake Pump
Maximum height of discharge
vented loop 6 Ft. (1.8m) from base of toilet
INSTALLATION
Recommended Wire and Breaker Sizes for Crown Head II with Diaphragm Intake Pump
Units
Voltage
12V DC
24V DC
32V DC
Main Circuit
Breaker/Fuse Amps
40
20
15
Discharge Pump
Assembly Amps
18
9
7
Recommended Wire and Breaker Sizes for Crown Head II with Pressurized Freshwater
Diaphragm Intake
Pump Amps
10
5
4
Units
Voltage
12V DC
24V DC
32V DC
Main Circuit
Breaker/Fuse Amps
25
15
10
Distance (feet) and Wire (AWG)
Discharge Pump
Assembly Amps
18
9
7
Water Solenoid
Valve Amps
1
.5
.5
10' 15' 20' 25' 30' 40' 50'
10 10 8 8 6 6 4
16 16 14 12 12 10 10
16 16 16 14 14 12 12
Branch Circuit Wire to Water Solenoid Valve: use 16 AWG Wire
Wire Sizes Conversion Table
16 14 12 10 8 6 4 2
1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0
AWG
mm2
7
NOTES: for Wire Sizes
1. Distances are from source (battery) to unit and back to source (battery).
2. Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.
3. Recommended conductor sizes are based on 105°C rated insulation.
Refer to ABYC Standards for other insulation ratings.
10' 15' 20' 25' 30' 40' 50'
10 8 6 6 4 4 2
16 14 12 12 10 10 8
16 16 16 16 16 16 14
Distance (feet) and Wire (AWG)
Pressurized water source must provide a minimum flow rate of 3 gallons
(11.3 liters) per minute at a minimum pressure of 5 psi (34.5 kPa).
Feet to Meter Conversion Table
10 15 20 25 30 40 50
3.1 4.6 6.1 7.2 9.2 12.2 15.2
Feet
Meter

Mounting Toilet
Mounting surface must be flat and solid.
IMPORTANT: Do not mount where it may be
subject to shower spray or other sources of
external water.
1. Install seat on toilet.
2. Place toilet where it will be located.
Make sure there is room to route hoses.
Make sure seat will open properly.
3. Mark location of toilet base mounting holes on
mounting surface.
4. Drill holes for toilet mounting bolts/screws.
NOTE: Hole size will depend on type of bolt/screws
used (5/16" [8mm] size bolts/screws are
recommended).
5. Mark locations for hoses where required.
6. Cut holes for hoses.
7. Place rubber mounting strips under base plate.
8. Secure toilet to surface.
Mounting Water Solenoid Valve
(Pressurized Freshwater Models Only)
1. Locate valve on a solid flat surface in an area
that is dry and well ventilated.
2. Mark and drill holes for water solenoid mounting
bracket.
NOTE: Hole size will depend on type of bolts/screws
used (1/4" [6mm] size bolt/screws are
recommended).
3. Mount bracket.
4. Install fittings provided (PLA14) on valve’s inlet
and outlet ports.
5. Attach valve to bracket. Valve must be mounted
according to flow markings on valve body.
INSTALLATION
From
Pressurized
Freshwater
Source
OUT PLA14
To Crown Head II
IN
8

Mounting Atmospheric Vacuum Breaker
(Pressurized Freshwater Model only)
1. Install fittings as shown.
2. Locate mounting area that is a minimum of
6" (15.3cm) above toilet.
3. Secure where top is in horizontal position.
Mounting In-Line Strainer
(Seawater Models Only)
Make sure strainer bowl is tight.
1. Locate strainer where it will be accessible.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Install fittings provided (#PLA14) on strainer’s
inlet and outlet ports.
4. Mount strainer. Strainer must be mounted
according to flow markings on strainer body.
Mounting Remote Intake Pump
(Sea Models Only)
1. Locate on a flat solid surface in an area that is
dry and well ventilated.
NOTE: Location should not be greater than 48"
(122cm) above the waterline.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/
screws used (1/4" [6mm] size bolts/screws are
recommended).
3. Mount pump. Do not over tighten bolts.
Installing Lower Cover
1. Slide cover over lower unit.
2. Secure in place with plastic beaded tie.
NOTE: Do not install until installation is
completed.
INSTALLATION
Flow Marking
6"
(15.3cm)
➔
➔
9

INSTALLATION
PLUMBING
WARNING: Hazard of Flooding
Toilets mounted at or below the waterline must
have a vented loop installed in the discharge
line. The top of the vented loop must be a
minimum of 4" (10cm) above the waterline at
the boats greatest angle of heel (see vented loop
manufacturer’s instructions).
Sea Water Models must also have a vented loop
installed between the intake pump and the
toilet bowl.
Double clamp all below waterline connections.
• Hazard of potable water contamination.
Vacuum breaker must be installed with
installations using potable water.
IMPORTANT:
•Fittings and 90° bends should be kept to a
minimum.
• In-Line Strainer must be installed before
the Remote Intake pump. Failure to do so
may void warranty.
•Discharging untreated sewage is restricted
in all U. S. waters within the three-mile
limit. If boating outside of U.S. Boundaries
check with local authorities for their rules
and regulations.
•Thru-hull fittings and seacocks must be
installed where they are easily accessible.
•Use only quality reinforced hoses.
•Secure all hoses properly.
Discharge Lines
1. Connect quality 1 1/2" (38mm) sanitation
hose to discharge fitting on toilet.
2. Run hose to appropriate device (i.e.: treatment
system, holding tank, etc.).
Pressurized Freshwater Model
Installed Above Waterline
Crown head II
Holding Tank
Holding Tank
Crown head II
Vacuum
Breaker
Waterline
Crown head II
Waterline
Water
Solenoid
Valve
Shut off
Valve
Remote Intake Pump Model
Mounted Above Waterline
Remote
Intake
Pump
In-Line
Strainer
Lectra/San
Discharge
Vented
Loop
Waterline
Intake
Seacock
Y Valve Discharge
Seacock
Lectra/San
Waterline
Waterline
Intake
Seacock
Intake
Vented
Loop
Discharge
Seacock
Discharge
Vented
Loop
Remote Intake
Pump
In-Line
Strainer
Remote Intake Pump Model
Mounted Below Waterline