Thank you for purchasing this series UPS.
This series UPS is an intelligent, three phase in Three phase out, high frequency online
UPS designed by our R&D team who is with years of designing experiences on UPS.
With excellent electrical performance, perfect intelligent monitoring and network
functions, smart appearance, complying with EMC and safety standards, The UPS
meets the world’s advanced level.
Read this manual carefully before installation
This manual provides technical support to the operator of the equipment.

1
Contents
1.Safety ....................................................................................................................................... 2
1.1 Safety notes ....................................................................................................................................... 2
1.2 Symbols used in this guide ............................................................................................................ 2
2.Main Features ........................................................................................................................ 3
2.1 Summarization ................................................................................................................................... 3
2.2 Functions and Features .................................................................................................................. 3
2.3 Model description ............................................................................................................................. 4
3.Installation .............................................................................................................................. 4
3.1 Unpack checking .............................................................................................................................. 5
3.2 The appearance of the product ..................................................................................................... 5
3.3 UPS module appearance .............................................................................................................. 16
3.4 Installation notes ............................................................................................................................ 17
3.5 External Protective Devices .......................................................................................................... 18
3.6 Power Cables ................................................................................................................................... 18
3.7 Power cable connect...................................................................................................................... 22
3.9 Battery connection ......................................................................................................................... 23
3.10 Online UPS Modules Replacement .......................................................................................... 24
3.11 UPS Multi-Module Installation ................................................................................................. 25
3.11.1 Cabinet installation ........................................................................................................... 25
3.11.2 Parallel cable installation ................................................................................................ 26
3.12 LBS installation (optional) .......................................................................................................... 27
3.12.1 LCD setting ......................................................................................................................... 27
3.12.2 LBS cable installation ...................................................................................................... 27
3.12.3 UPS installation ................................................................................................................. 28
4.Operation .............................................................................................................................. 28
4.1 Operation Modes ............................................................................................................................. 28
4.2 Turn on/off UPS ............................................................................................................................... 31
4.2.1 Restart procedure ................................................................................................................ 31
4.2.2 Test procedure ..................................................................................................................... 31
4.2.3 Cold start procedure ........................................................................................................... 32
4.2.4 MAINTENANCE BYPASS ................................................................................................... 32
4.2.5 Shut down procedure ......................................................................................................... 33
4.2.6 Startup procedure for parallel system ........................................................................... 34
4.3 The Display ....................................................................................................................................... 34
4.4 Display Messages/Troubleshooting ........................................................................................... 42
4.5 Options .............................................................................................................................................. 44
Appendix 1 Specifications ..................................................................................................... 45
Appendix 2 Problems and Solution ..................................................................................... 48
Appendix 3 CAN communication port definition ............................................................. 50
Appendix 4 RS485 communication port definition ......................................................... 50
Appendix 5 COM communication port definition ............................................................ 51
Appendix 6 LBS port definition ............................................................................................ 52
Appendix 7 REPO instruction ............................................................................................... 53

2
1.Safety
Important safety instructions – Save these instructions
There exists dangerous voltage and high temperature inside the UPS. During the
installation, operation and maintenance, please abide the local safety instructions and relative
laws, otherwise it will result in personnel injury or equipment damage. Safety instructions in this
manual act as a supplementary for the local safety instructions. Our company will not assume the
liability that caused by disobeying safety instructions.
1.1 Safety notes
1. Even no connection with utility power, 220/230/240VAC voltage may still exist at UPS outlet!
2. For the sake of human being safety, please well earth the UPS before starting it.
3.Don’t open or damage battery, for the liquid spilled from the battery is strongly poisonous and
do harmful to body!
4.Please avoid short circuit between anode and cathode of battery, otherwise, it will cause
spark or fire!
5.Don’t disassemble the UPS cover, or there may be an electric shock!
6.Check if there exists high voltage before touching the battery
7.Working environment and storage way will affect the lifetime and reliability of the UPS. Avoid
the UPS from working under following environment for long time
◆ Area where the humidity and temperature is out of the specified range (temperature 0
to 40℃, relative humidity 5%-95%)
◆ Direct sunlight or location nearby heat
◆ Vibration Area with possibility to get the UPS crashed.
◆ Area with erosive gas, flammable gas, excessive dust, etc
8.Keep ventilations in good conditions otherwise the components inside the UPS will be
over-heated which may affect the life of the UPS.
1.2 Symbols used in this guide
WARNING!
Risk of electric shock
CAUTION!

3
Read this information to avoid equipment damage
2.Main Features
2.1 Summarization
Our UPS is a kind of three-in- three -out high frequency online UPS, it provides three
specifications: The 150~600kVA. The products are modularized and adopt the N+X redundancy.
It can flexibly increase the number of the UPS modules according to the load capacity which is
convenient for flexible allocation and gradually investment.
The UPS can solve most of the power supply problems, such as blackout, over-voltage,
under-voltage, voltage sudden drop, oscillating of decreasing extent, high voltage pulse, voltage
fluctuation, surge, inrush current, harmonic distortion (THD), noise interference, frequency
fluctuation, etc..
This UPS can be applied to different applications from computer device, automatic equipment,
communication system to industry equipment
2.2 Functions and Features
◆Digital control
◆19-inch standard cabinet
1.2-meter, 1.6-meter and 2-meter high cabinets are provided according to the user’s
requirement.
◆Modularized design
◆High power-density design
The height of the single module is 3U.
◆N+X parallel redundancy
This series UPS adopts N+X parallel redundancy design, user can set different redundancy
according to the importance of the load. While the redundancy modules are set more than two,
the availability of UPS system will achieve 99.999%, which may satisfy the required reliability of
the critical load connected. Through LCD display setting, you may configure the required quantity
of the redundancy unit. When the load connected is over the number of the redundancy, the UPS
will alert right away. The design of the MTBF (Meantime before Failure) is up to 250,000 hours.
This series can set the number of redundancy modules. When the load exceeds the
redundancy setting, the UPS can still work normally and simultaneously send out corresponding
warning as long as the load doesn’t exceed the total capacity of modules.
◆Parallel redundant control system
◆Optimizing distributed convergence for the cabinet
◆Centralized bypass
◆Common Battery
◆Automatic charge current adjustment according to battery capacity connected.
◆3-Stage Intelligent charging
◆Touch-screen Super-large LCD display
◆Remote monitoring via SNMP
◆Optional Accessories available such as Isolation transformer, distribution Panel, SNMP Card,
Relay Contact Board, etc...
◆Equip with Maintenance Bypass Switch for easy maintenance purpose.

4
◆Superior MTTR (Meantime to repair) & Short shutdown time in maintenance
◆Centralized monitoring module is also available
◆EPO and REPO function
2.3 Model description
This document describes the following UPS models:
◆ 150kVA
The models provide 3 configurations: 50 kVA, 100 kVA and 150 kVA.
◆ 250kVA
The models provide 5 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA and 250 kVA.
◆ 200kVA
The models provide 4 configurations: 50 kVA, 100 kVA, 150 kVA and 200 kVA
◆ 300kVA
The models provide 6 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA
and 300 kVA.
◆ 400kVA
The models provide 8 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA, 300 kVA,
350 kVA and 400 kVA.
◆ 500kVA
The models provide 10 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA,
300 kVA, 350 kVA, 400 kVA, 450 kVA and 400 kVA.
◆ 600kVA
The models provide 12 configurations: 50 kVA, 100 kVA, 150 kVA, 200 kVA, 250 kVA,
300 kVA, 350 kVA, 400 kVA, 450 kVA, 500 kVA, 550 kVA and 400 kVA.
◆ 150kVA supports cable routing from the bottom.
◆ 250kVA supports cable routing from the bottom.
◆ 200kVA supports cable routing from the top and can support cable routing
◆ 300kVA supports cable routing from the top and can support cable routing
from the bottom if a cable entry cabinet is configured.
◆ 400kVA standard cabinet supports cable routing from the top.
◆ 400kVA full configuration cabinet supports cable routing from the bottom and top.
◆ 500kVA supports cable routing from the bottom and top.
◆ 600kVA supports cable routing from the bottom and top.
* Standard configuration : cabinet only with maintenance bypass switch
* Full configuration : cabinet with mains, bypass, maintenance and output switch
3.Installation

5
3.1 Unpack checking
1. Don’t lean the UPS when moving it out from the packaging
2. Check the appearance to see if the UPS is damaged or not during the transportation, do
not switch on the UPS if any damage found. Please contact the dealer right away.
3. Check the accessories according to the packing list and contact the dealer in case of
missing parts.
3.2 The appearance of the product
150kVA(Full configuration)
Front View Side View Rear View

6
Front View (internal)
250kVA(Full configuration)
Front View Side View Rear View
Front View (internal) Front View (Copper bar)
200/300/400kVA(Standard and Full configuration)

7
Front View Side View Rear View
200kVA(Standard and Full configuration)

8
standard configuration full configuration
Connect copper bar

9
300kVA(Standard and Full configuration)
standard configuration full configuration
Connect copper bar
Tabla de contenidos
Manuales populares de Unión Postal Universal de otras marcas

Pylontech
Pylontech Victron & Pylontech US5000 Manual de usuario

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manual de usuario

Mecer
Mecer ME-1000-WTU Manual de usuario

Mustek
Mustek PowerMust 530(B) Plus Manual de instalación y operación

Emerson
Emerson Liebert NXL series Manual de usuario

MAKELSAN
MAKELSAN BOXER SERIES Manual de usuario