Rae MultiRAE PLUS PGM-50 Manual de usuario

MultiRAE PLUS
MULTI-GAS MONITOR
PGM-50
OPERATION AND MAINTENANCE
MANUAL
(Document No.: 008-4001)
Rev. G
RAE SYSTEMS INC.
1339 Moffett ParkDrive
Sunnyvale, CA 94089
October 2001

RAE Systems Product Line
§Gas Detection Tubes & Pumps
§SampleRAE Electronic Sampling Pump
§MultiRAE PLUS Multi-gas Monitors
§MultiRAE IR Multi-gas Monitors w/CO2
§MultiRAE Confined Space Monitor
§QRAE PLUS Multi-gas Monitors
§QRAE Confined Space Monitor
§VRAE Five-Gas Monitors
§DRAE Two-Gas Monitors
§MiniRAE 2000 Portable VOC Monitor (PID)
§ppbRAE Portable ppb-Level VOC Monitor (PID)
§UltraRAE Specific Compound Monitor
§CDRAE Corona Discharge VOC Monitor
§ToxiRAE PLUS PID Monitor
§ToxiRAE PLUS Single Gas Monitors
§ToxiRAE PLUS Oxygen Monitor
§ToxiRAE PLUS Combustible Gas Monitor
§MiniRAE PLUS Classic PID
§ModuRAE Fixed System PID
§AreaRAE Wireless Multi-point, Multi-gas Detection
Systems
How can I be informed and updated?
Be sure to mail in your warranty card via email, post or fax to get on
RAE’s private database (information is never supplied to others).

You will be updated on new products, technical advisory notices, new
accessories and much more. Thank you for your purchase!

i
Table of Contents
1.GENERAL INFORMATION.......................................1-1
1.1 General Specifications...........................................1-2
2. OPERATION OF MULTIRAE PLUS.........................2-1
2.1 Physical Description..............................................2-2
2.2 Keys and Display....................................................2-4
2.3 Power On/Off.........................................................2-7
2.4 Operations.............................................................2-10
2.5 Alarm Signals........................................................2-17
2.6 Back Light.............................................................2-20
2.7 Preset Alarm Limits and Calibration..................2-21
2.8 Integrated Sampling Pump...................................2-22
2.9 Datalogging...........................................................2-24
3. OPERATION OF ACCESSORIES..............................3-1
3.1 Battery Charging Operation...................................3-2
3.2 Alkaline Battery Adapter........................................3-4
3.3 Water Trap Filter....................................................3-5
3.4 Remote Sampling Probe or Tygon Tubing...........3-6
3.5 Dilution Fitting.......................................................3-7
3.6 Calibration Adapter................................................3-8
4. PROGRAMMING OF MULTIRAE PLUS...............4-1
4.1 Programming Mode ...............................................4-2
4.2 Keys for Programming Mode ...............................4-4
4.3 Entering into Programming Menu........................4-5
4.4 Calibration of MultiRAE PLUS Monitor.............4-7
4.4.1 Fresh Air Calibration.......................................4-10
4.4.2 Multiple Sensor Calibration..............................4-11
4.4.3 Single Sensor Calibration.................................4-14
4.4.4 Modify Span Gas Value...................................4-17
4.4.5 Change LEL/VOC Span Gas...........................4-18
4.5 Change Alarm Limits...........................................4-20

ii
4.6 View or Change Datalog......................................4-22
4.6.1 Reset Peak and Minimum ................................4-23
4.6.2 Clear All Data 4-24
4.6.3 Change Datalog Period....................................4-25
4.6.4 Select Data Type.............................................4-26
4.6.5 View Datalog..................................................4-27
4.6.6 Enable / Disable Datalog..................................4-28
4.7 Change Monitor Setup.........................................4-29
4.7.1 Change Site ID 4-30
4.7.2 Change Alarm Mode.......................................4-31
4.7.3 Change User Mode.........................................4-32
4.7.4 Change Real Time Clock.................................4-33
4.7.5 Change Back Light Mode................................4-34
4.7.6 Change Password............................................4-35
4.7.7 Change Pump Speed.......................................4-36
4.7.8 Change Averaging Method ..............................4-37
4.8 Change Sensor Configuration..............................4-38
4.8.1 Change LEL/VOC Gas Selection.....................4-40
4.8.2 Enable / Disable Sensor...................................4-44
4.8.3 Change Dilution Ratio ......................................4-45
4.8.4 Change PID Lamp Type..................................4-46
4.9 Exit Programming Mode .....................................4-47
5. COMPUTER INTERFACE
FOR MULTIRAE PLUS...........................................5-1
5.1 Install ProRAE-Suite Software.............................5-2
5.2 Connect MultiRAE PLUS to PC...........................5-4
5.3 Start ProRAE-Suite Software................................5-4
5.4 Setup Communication Port...................................5-7
5.5 Processing the Configuration Data.......................5-8
5.5.1 Editing the Configuration Data............................5-9
5.5.2 Send Configuration to MultiRAE Plus...............5-21
5.5.3 Saving Configuration Data................................5-22
5.5.4 Configuring All Settings....................................5-23

iii
5.6 Processing the Logged Data................................5-24
5.6.1 Receive Data from MultiRAE PLUS ................5-25
5.6.2 View Logged Data in Text Mode.....................5-26
5.6.3 View STEL/TWA/AVG Value ........................5-28
5.6.4 View Summary Information..............................5-29
5.6.5 View Logged Data in Graph Mode..................5-30
5.6.6 Export the Displayed Data to a Text File..........5-34
5.6.7 Export Graphic to a File...................................5-35
5.6.8 Print the Logged Data......................................5-36
5.7 Upgrade the Datalog Option................................5-37
5.8 Upgrade the Firmware..........................................5-39
6. THEORY OF OPERATION.........................................6-1
7. MAINTENANCE............................................................7-1
7.1 Battery Replacement..............................................7-2
7.2 Sensor Replacement...............................................7-4
7.3 PID Sensor Cleaning / Replacement.....................7-7
7.4 PID Lamp Care.......................................................7-9
7.5 Sampling Pump Replacement..............................7-11
8. TROUBLESHOOTING.................................................8-1
8.1 Special Diagnostic Mode.......................................8-2
8.2 Troubleshooting Table.........................................8-10
APPENDIX A. QUICK REFERENCE GUIDE.............A-1
APPENDIX B. CORRECTION FACTORS...................B-1
APPENDIX C. MULTIRAE PLUS DATA
CONVERSION TO MICROSOFT EXCEL.............C-1
APPENDIX D. RAE SYSTEMS TECHNICAL
NOTES..............................................................................D-3
APPENDIX E. RAE SYSTEMS APPLICATION
NOTES..............................................................................E-1
APPENDIX F. LITERATURE REQUEST.....................F-1
APPENDIX G. REQUESTFOR RETURN
AUTHORIZATION FORM..........................................G-1
Main Contact Numbers..........................Outer Back Cover

iv
! WARNING !
-DONOT proceed before reading -
This manual must be carefully read by all
individuals who have or will have the responsibility
for using, maintaining, or servicing this product.
The product will perform as designed only if it is used,
maintained, and serviced in accordance with the
manufacturer's instructions.
CAUTION!!
To reduce the risk of electric shock, turn off power
before removing the monitor cover. Disconnect
the battery before removing sensor module for
service. Never operate the monitor while the cover
is removed. Remove monitor cover and sensor
module only in an area known to be non-
hazardous.
The model PGM-50 equipment is classified as to
intrinsic safety for use in class I, division 1, groups
A, B, C, D, or non-hazardous locations only.

v
Special Note
-1-
When the PGM-50 Multi-gas Monitor is taken out from
the transport case and turned on for the first time, there
may be some residual organic or inorganic vapor
trapped inside the detector chamber. The initial PID or
toxic sensor reading may indicate a few ppm. Ensure an
area free of organic or toxic vapor and turn on the
monitor. After running for several minutes, the residual
vapor in the detector chamber will be cleared and the
reading should return to zero.
-2-
The battery of the MultiRAE PLUS monitor will
discharge slowly even if it is turned off. If the monitor
has not been charged for 5-7 days, the battery voltage
will be low. Therefore, it is a good practice to always
charge the monitor before using it. It is also
recommended to fully charge the monitor for AT LEAST
10 HOURS before initial use (see Section 7 for more
information on battery charging and replacement).

vi
WARNINGS:
Use only RAE Systems battery packs, part Nos. 500-
0028, 500-0029, or 500-0039. This instrument has
not been tested in an explosive gas/air atmosphere
having an oxygen concentration greater than 21%.
Substitution of components may impair intrinsic
safety. Recharge batteries only in non-hazardous
locations.
AVERTISSEMENT:
Utiliser seulement l'ensemble de batterie RAE
Systems, la reference 500-0028, 500-0029 au 500-
0039. Cet instrument n’a pas été essayé dans une
atmosphère de gaz/air explosive ayant une
concentration d’oxygène plus élevée que 21%. La
substitution de composants puet compromettre la
sécurité intrinsique. Ne charger les batteries que
dans emplacements désignés non dangereuse.
STATIC HAZARD:
Clean only with a damp cloth.
DANGER RISQUE D'ORIGINE ELECTROSTATIQUE:
Nettoyer uniquement avec un chiffon humide.

vii
CAUTION:
For safety reasons this equipment must be operated
and serviced by qualified personnel only. Read and
understand instruction manual completely before
operating or servicing.
ATTENTION:
Pour des raisons de sécurité, cet équipment doit
être utilisé, entretenu et réparé uniquement par un
personnel qualifié. Étudier le manuel d’instructions
en entier avant d’utiliser, d’entretenir ou de réparer
l’équipement.
Tabla de contenidos
Otros manuales de Monitor de Rae

Rae
Rae MultiRAE Manual de usuario

Rae
Rae PGM62x6 Manual de usuario

Rae
Rae AreaRAE-Gamma PGM-5120 Manual

Rae
Rae Q-RAE PLUS Manual

Rae
Rae ToxiRAE II PGM-1100 Series Manual de usuario

Rae
Rae QRAE 3 Manual de usuario

Rae
Rae RAEGuard 2 PID Manual de usuario

Rae
Rae QRAE PLUS PGM-2000 Manual

Rae
Rae EntryRAE PGM-3000 Manual de usuario