46
R1K 18 - RAD - ING - Manuale - 1706.1_V3
2 Dati tecnici_R1K 18_ErP_EN15502_EN
2. MAINTENANCE
SUPPORT CENTRE
Technical parameters for boiler space heaters, boiler combination heaters and cogeneration
space heaters
Model R1K 18
Condensing boiler
Low-temperature (**) boiler:
B11 boiler
Cogeneration space heater
If yes, equipped with a supplementary heater
Combination heater
Rated heat output Prated
[yes/no] yes
[yes/no] no
[yes/no] no
[yes/no] no
[yes/no] no
[yes/no] no
kW 17.40
For boiler space heaters and boiler combination
heaters: Useful heat output
At rated heat output and high-temperature regime (*) P4kW 17.40
At 30 % of rated heat output and lo w- tempe rature re gi me (* *)
P1
kW 5.40
For cogeneration space heaters: Useful heat output
At rated heat output of cogeneration space heater with
supplementary heater disabled PCHP100+Sup0
kW -
At rated heat output of cogeneration space heater with
supplementary heater enabled PCHP100+Sup100
kW -
)RUFRJHQHUDWLRQVSDFHKHDWHUV(OHFWULFDOHI¿FLHQF\
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUGLVDEOHGȘel,CHP100+Sup0
%-
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUHQDEOHGȘel,CHP100+Sup100
%-
$X[LOLDU\HOHFWULFLW\FRQVXPSWLRQ
At full load elmax kW 0.04
At part load elmin kW 0.02
In standby mode PSB kW 0.004
6HDVRQDOVSDFHKHDWLQJHQHUJ\HI¿FLHQF\Șs%91
6HDVRQDOVSDFHKHDWLQJHQHUJ\HI¿FLHQF\FODVV A
For boiler space heaters and boiler combination heaters:
8VHIXOHI¿FLHQF\
$WUDWHGKHDWRXWSXWDQGKLJKWHPSHUDWXUHUHJLPHȘ4%86.9
At 30 % of rated heat output and low-temperature regime
Ș1
%96.8
)RUFRJHQHUDWLRQVSDFHKHDWHUV8VHIXOHI¿FLHQF\
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUGLVDEOHGȘCHP100+Sup0
%-
At rated heat output of cogeneration space heater with
VXSSOHPHQWDU\KHDWHUHQDEOHGȘCHP100+Sup100
%-
6XSSOHPHQWDU\KHDWHU
Rated heat output Psup kW -
Type of energy input -
Other items
Standby heat loss Pstby kW 0.1
Ignition burner power consumption Pign kW 0.0