Before you Begin
1. Check the mains water pressure. The pressure must
not be below 1.5 BAR (22 psi) or above 5 BAR (73 psi),
measured during a low demand period – (mid-morning or
mid-aernoon).
If the pressure exceeds 5 BAR a pressure reducing valve
must be installed in the cold mains supply to protect both
the boiler and the water lter housing. A suitable pressure
reducing valve can be purchased at www.grldirect.co.uk/
franke
2. The unit must be installed in a frost free environment.
3. Ensure that the cabinet is well venlated. If in doubt it is
advisable to improve the circulaon of air by drilling some
holes in the top and boom of the rear panel.
4. Be careful when making the connecons to the chiller.
Do not be tempted to over-ghten the connecons. It is
only necessary to rmly hand ghten the nuts using the
patented NutRunna® plasc ghtening devices provided to
make a secure waterght seal.
5. Shut o the mains water supply.
6. Switch o the mains electricity supply at the socket.
7. Covering the chiller will cause it to overheat, aecng its
performance and potenally causing it to shut down.
8. Ensure that the chiller is seated on a at surface, well
venlated and not in direct sunlight.
9. A kitchen base unit not less than 800mm wide, good
venlaon within the cabinet to allow cooling of the chiller
unit.
Where possible you should provide a vent in the base and
one near the top of the cabinet to allow air to ow. You
must provide a 75mm air gap on all sides of the cooler unit.
Introducon
Thank you for purchasing this QETTLE Chiller system. Correctly installed and properly maintained in
accordance with the following instrucons, it will provide you with reliable service for many years. This
guide explains how to install a new water chiller system.
Warranty
This product is a water chilling device intended for domesc use only. The water supply pressure must be
between minimum 1.5 BAR (22 psi) maximum 5 BAR (73 psi).
Descripon Value Unit
Dimensions 180w x 320h
x 370d
mm
Load 10 Amps
Voltage 230 Volts
Power
(Compressor)
160 Was
Min Water
Pressure
1.5 Bar
Max Water
Pressure
5 Bar
Cooling Time 20 Mins
Recovery
Time
15 Mins
Tank
Capacity
1.2 Litres
Dispensing
Temperature
3-6 ˚C
Dispensing
Capacity at
4 ˚C - 10 ˚C
0.9 Litres
Weight 12 Kg
Refrigerant R-134A N/A
Decibel Rang 38 dB
Component List
1. Water Chiller (x1)
2. Inlet Hose - Red idencaon (x1)
3. Outlet Hose - Blue idencaon (x1)
4. 3/8” Straight JG Push Fit Connector (x2)
5. 3/8”-1/4” Straight JG Push Fit
Connector (x2)

Installing the Chiller
Please Note: This chiller is supplied with xtures and ngs that are compable with most kitchen tap appliances.
However, should you nd any of the ngs provided are not compable with your tap, please contact us with details
of your tap’s brand and model—and we will endeavour to help you. For ease of installaon the chiller connecons
and the exible hoses are colour coded: Blue - Water outlet. Red - Water inlet.
1. IMPORTANT Do not plug the chiller into the power supply unl the installaon process has been completed.
2. Remove the protecve caps from the three connecons on the top of the chiller.
3. Place the chiller in an upright posion on a at surface inside the cabinet with the connecons to the top.
4. See below photo — Take the water inlet hose (red indicator) and screw onto chiller inlet (red arrow). Hand ghten
using the aached NutRunna® sucient to make a waterght seal. Do not overghten.
5. See below photo — Take the water outlet hose, (blue indicator) and screw onto chiller outlet (blue arrow). Hand
ghten using the aached NutRunna® sucient to make a waterght seal. Do not overghten.
6. See below photo —Take the free end of the inlet hose and connect to your lter system using either one of the
connectors that are supplied, depending whether your system uses 1/4” diameter or 3/8” diameter exible tubing.
7. See below photos—Take the free end of the outlet hose and connect to your tap inlet using either one of the
connectors that are supplied, depending whether your system uses 1/4” diameter or 3/8” diameter exible tubing.
8. Turn on the water supply.
9. Operate the chilled water funcon on your tap for 3 minutes to ush the system.
10. Turn the tap o and check the connecons for leaks.
11. Plug the chiller into the mains electricity supply socket.
12. Switch the chiller to the “ON” posion. Check the top LED (plug icon) on the chiller’s front cover turns green to
indicate power is on. The lower LED (mug icon on chiller’s cover) will turn red to indicate the chiller is in operaon.
13. Allow approximately 20 minutes for the chiller to reach full operang temperature, indicated by the lower LED
turning green.
Components 2 & 3 Components 4 & 5
3/8”—1/4”
Straight JG Push-Fit
Connector
QUANTITY— 2
3/8”—3/8”
Straight JG Push-Fit
Connector
QUANTITY—2
Aaching the water inlet hose (red) Aaching the water outlet hose (blue)

Guarantee
This QETTLE product carries a 3 year warranty against material and manufacturing defects. The warranty will be valid
from the date of purchase as shown on the sales invoice. Please keep the invoice for your records. This appliance is
intended for domesc use only. The warranty does not apply to products installed outside a domesc environment.
Warranty
What is covered by the QETTLE guarantee?
• The repair or replacement of all or part of your system if your system is found to be defecve due to faulty
materials or manufacture within 3 years of purchase at QETTLE’s discreon.
• If any part is no longer available, or out of manufacture, QETTLE reserve the right to replace it with a suitable
alternave.
• Terms and condions of the QETTLE 3 year guarantee.
• The guarantee is valid for the UK and Republic of Ireland.
• The guarantee becomes eecve at the date of purchase or at the date of delivery if this is later. Proof of
purchase is required under the terms of the guarantee.
• The guarantee provides benets in addion to your statutory consumer rights.
QETTLE does not guarantee the repair or replacement of a product that has failed for any of the following reasons:
• Faulty installaon, repairs or alteraons not in accordance with the installaon guide.
• Normal wear and tear.
• Accidental damage or faults caused by negligent use or care; misuse; neglect; careless operaon and failure to
use the system in accordance with the QETTLE operang guidelines.
• Failures of, or failures caused by, parts not supplied with the QETTLE system.
Aer Sales Service
QETTLE
Old Winery Business Park
Chapel Street
Cawston, Norfolk
NR10 4FE
+44 (0) 1603 875 464
support@qele.com
www.qele.com
The QETTLE chiller is compliant in accordance with the following direcves: 2006/95/EC Low Voltage Direcve 2011/65/EU RoHS Direcve 2009/125/EC Eco Design
Direcve Protecon Level: IP20 The QETTLE chiller conforms to the requirements of the relevant EU guidelines. The symbol on the product or on its packaging indicates
that this product may not be treated as household waste. Instead it shall be handed over to the applicable collecon point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will help prevent potenal negave consequences for the environment and human health, which could
otherwise be caused by inappropriate waste handling of this product. For more detailed informaon about recycling of this product, please contact your local city oce,
your household waste disposal service or the shop where you purchased the product.
DECLARATION OF CONFORMITY
The QETTLE Chiller is a product of Greg Rowe Ltd. QETTLE is a trading name of Greg Rowe Limited.