PureAire 1500 Manual de usuario

Owner’s Manual
1500

2
Welcome
Thank you for your purchase of the pureAir 1500. This air purifier has
been designed to provide you a cleaner living space with years of
low maintenance operation.
Please read through the usage and service instructions outlined in this
owner’s manual before operating the unit.
Table of Contents
Product Contents
Warnings ............................................... 3
Diagrams.............................................4 - 5
Getting Started.......................................... 6
Settings ................................................ 7
Disassembly/Assembly ................................. 8 - 9
Cleaning ........................................... 10 - 11
Maintenance .......................................... 12
Troubleshooting ........................................ 13
Specifications .......................................... 14
Warranty Information .....................................15
1pureAir 1500 Unit 1 Owner’s Manual
1 Power Cord 1 DC Adapter
1 Remote with Battery

3
Do not operate this unit unless it is completely assembled.
Eye damage may result from directly viewing the light
produced by the lamp inside this unit for a continuous
and extended period of time.
Do not block the ventilation or filters.
Do not use Away Mode in an occupied space.
The unit should be powered OFF and the POWER CORD
disconnected whenever cleaning or servicing.
There are no user-serviceable parts inside the unit.
This unit is not intended for outdoor use.
Warnings

4
Diagrams
Unit Front
Power Plug
Ionization
Brushes
Fan
Front Grille
Power Adapter
Control Panel
Rear Panel
Release Tab
Unit Rear
(Closed)

5
Diagrams
PURIFICATION
POWER
AWAY
MODE
0
1
2
3
FAN
AWAY MODE
FAN
POWER
Control Panel Remote
Power
Power Plug Purification Plate
Power Connector
Purification
Plate
PCO Cell
Purification Level
LED Indicator
Purification
Level
PCO Cell
Power Connector
Fan Speed
Fan Speed
Away ModePower
Away Mode
Unit Rear
(Open)

6
Getting Started
1. Remove the UNIT and POWER ADAPTER from the packaging.
2. Find a suitable location to place your unit. (Ideal location is an area of the
room with good circulation, or near the source of pollution.)
3. Plug the POWER ADAPTER into a wall outlet and then plug the other end
into the POWER PORT of your unit.
4. Place the POWER ADAPTER into the open space in the rear of the unit.
5. Press the POWER BUTTON to control to power of your unit.
Your unit will start operating in PURIFICATION LEVEL 0/FAN SPEED HIGH.

7
There are multiple ways to change the output of your unit. If you need the
unit to be quieter, change the Fan Speed, if you need a larger or smaller
area covered, change the Purification Level, and if you need a tough odor
removed, use Away Mode.
Fan Speed
Three fan speeds are available (Low, Medium, High) and are adjusted with
the FAN UP/DOWN buttons on both the machine’s CONTROL PANEL as well
as with the REMOTE.
Purification Level
Purification level is controlled on the REMOTE and adjusts the output of
Activated Oxygen (O3). Four levels are available and will be signified by
varying colors on the CONTROL PANEL.
LEVEL 0 (0 - 250ft2): LED is OFF.
(Level 0 uses only PCO and Ionizaition Technology.)
LEVEL 1 (250 - 500ft2): LED is GREEN
LEVEL 2 (500 - 1000ft2): LED is YELLOW
LEVEL 3 (1000 - 1500ft2): LED is RED
Away Mode
Away Mode is used to treat the toughest odors in your space with higher
levels of Activated Oxygen and Ionization. To activate, press the AWAY
MODE BUTTON on the CONTROL PANEL or REMOTE.
Away Mode is active for 2 Hours before reverting back to previous settings.
Settings
DO NOT use Away Mode in an occupied space. Prolonged exposure to
Activated Oxygen may result in temporary respiratory or eye irritation.

8
Disassembly
Rear Cover
After unplugging and removing the POWER CORD and POWER ADAPTER,
press down on the tab above the POWER ADAPTER space and then pull
back on the REAR COVER.
Side Filters
After removing the REAR COVER, slide each of the FILTER ASSEMBLIES
straight out. These separate and contain 3 different filter pieces.
Purification Plate
(a) Locate the PURIFICATION PLATE CONNECTOR (Red Connector Piece) on
the right side of the unit. Squeeze the tabs on the left and right and gently
pull free. (b) Grasp the PURIFICATION PLATE, press the tabs towards the
middle and slide it out of its slot.
PCO Cell
(a) Locate the PCO CELL CONNECTOR (White Connector Piece) on the right
side of the unit. Squeeze the tabs on the left and right and gently pull free.
(b) Grasp the PCO CELL, and gently pull back to remove it from the slot.
Front Grille
Locate and remove the four FRONT GRILLE SCREWS in the four corners of
the FRONT GRILLE using a #1 Phillips Head Screwdriver. Place the screws
where you will find them again easily. Remove the FRONT GRILLE carefully
to ensure the IONIZATION BRUSH is not damaged.
Turn the unit OFF and remove the POWER CORD before performing any
cleaning or maintenance to prevent injury.
Refer to the Diagram Section (Pg. 4-5) for further illustrations of part names
and locations.

9
Assembly
Front Grille
Replace the FRONT GRILLE and the four FRONT GRILLE SCREWS using a
Phillips Head Screwdriver. Be careful to not over-tighten the screws or
damage the IONIZATION BRUSH.
PCO Cell
(a) Slide the PCO CELL back into the upper slot with the warning at the
top, facing out. (b) Plug the PCO CELL CONNECTOR back into the WHITE
CONNECTOR SLOT.
Purification Plate
(a) Slide the PURIFICATION PLATE back into the small slot with the larger silver
side facing to the left. (b) Plug the PURIFICATION PLATE CONNECTOR back
into the RED CONNECTOR SLOT.
Side Filters
Ensure that the FILTER ASSEMBLIES are snapped together correctly, then
replace the SIDE FILTERS in each of the side slots with the rounded edges
facing outwards.
Rear Cover
Place the REAR COVER bottom edge into the hinge slot then push forwards
until the tab clicks.
Power Cord
Insert the POWER ADAPTER into the rear slot and then replace the POWER
CORD in the POWER PORT.
All parts must be properly installed before operating the unit. Failure to do so
may damage the unit.

10
Cleaning
For proper operation, the unit should be cleaned at least once per month.
Unit Exterior
Wipe down the exterior with a damp cloth or use compressed air or a
vacuum cleaner to remove dust. A non-abrasive cleaner may be used on
the surfaces of the exterior.
Filter Assembly
Clean water or compressed air may be passed through the entire filter
assemblies or the individual parts when disassembled. To disassemble the
FILTER ASSEMBLIES grasp the sides of the rim and carefully separate the back
piece from the housing. The three filters [mesh, foam, honeycomb] can
then be removed and cleaned separately. If using water you must allow the
filters to fully dry before reassembly. When reassembling, the HONEYCOMB
FILTER goes in first, then the FOAM FILTER, and finally the thin MESH FILTER.
Then simply reattach the rear piece to the housing.
Turn the unit OFF and remove the POWER CORD before performing any
cleaning or maintenance to prevent injury.
Review the Disassembly and Assembly Section (Pg. 8-9) before performing
and cleaning and maintenance to prevent damage to the unit.
Tabla de contenidos
Otros manuales de Purificador de aire de PureAire