ProSoft Technology InRax PC56 Manual de usuario

PC56
ControlLogix Platform
In-Rack Industrial PC
November 18, 2009
QUICK START GUIDE

PC56 Modules
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN
SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DÉCONNECTER L'EQUIPMENT, COUPER LE
COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DÉSIGNÉ NON DANGEREUX.
Temp Code T5
II 3 G
Ex nA IIC T5 X
0° C <= Ta <= 60° C
II - Equipment intended for above ground use (not for use in mines).
3 - Category 3 equipment, investigated for normal operation only.
G - Equipment protected against explosive gasses.
Warnings
ATEX Warnings and Conditions of Safe Usage:
Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction
A Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules.
B Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is
known to be non-hazardous.
C These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to
prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used
only with ATEX certified backplanes.
D DO NOT OPEN WHEN ENERGIZED.
Electrical Ratings
Backplane Current Load on PC56: 1A @ 5 V DC
Backplane Current Load on IDE: 1A @ 5 V DC
Operating Temperature: 0 to 60°C (32 to 140°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Shock: 30g Operational; 50g non-operational; Vibration: 5 g from 10 to 150 Hz
Relative Humidity 5% to 95% (non-condensing)
All phase conductor sizes must be at least 1.3 mm(squared) and all earth ground conductors must be at least
4mm(squared).
Markings:
CSA/cUL C22.2 No. 213-1987
CSA CB Certified IEC61010
ATEX EN60079-0 Category 3, Zone 2
EN60079-15
243333

PC56™ Battery Warning
PC56 CMOS BIOS settings are protected by a rechargeable battery during power-down situations. The battery must
be fully charged before you change BIOS settings. You must keep the unit powered up for a full 20 hours in order to
obtain full charge capacity. If the battery is not fully charged, changes to BIOS settings may be lost when the PC56 is
removed from its power source. In this situation, the PC56 reverts to its default BIOS settings when power is re-
applied.
If the battery is discharged, or the battery enable jumper is removed, the BAT LED will be illuminated red. A fully
charged battery should maintain the BIOS settings for 15 days without power.
Your Feedback Please
We always want you to feel that you made the right decision to use our products. If you have suggestions, comments,
compliments or complaints about the product, documentation, or support, please write or call us.
ProSoft Technology
5201 Truxtun Ave., 3rd Floor
Bakersfield, CA 93309
+1 (661) 716-5100
+1 (661) 716-5101 (Fax)
www.prosoft-technology.com
support@prosoft-technology.com
Copyright © ProSoft Technology, Inc. 2009. All Rights Reserved.
PC56 Quick Start Guide
November 18, 2009
ProSoft Technology ®, ProLinx ®, inRAx ®, ProTalk®, and RadioLinx ®are Registered Trademarks of ProSoft
Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products
and services of, their respective owners.
ProSoft Technology®Product Documentation
In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments.
User Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided on the enclosed CD-ROM,
and are available at no charge from our web site: www.prosoft-technology.com
Printed documentation is available for purchase. Contact ProSoft Technology for pricing and availability.
North America: +1.661.716.5100
Asia Pacific: +603.7724.2080
Europe, Middle East, Africa: +33 (0) 5.3436.87.20
Latin America: +1.281.298.9109


Contents PC56 ♦ControlLogix Platform
Quick Start Guide In-Rack Industrial PC
ProSoft Technology, Inc. Page 5 of 25
November 18, 2009
Contents
PC56 Modules.....................................................................................................................................2
Warnings.............................................................................................................................................2
PC56™ Battery Warning.....................................................................................................................3
Your Feedback Please........................................................................................................................3
ProSoft Technology®Product Documentation....................................................................................3
1Installing the PC56 Embedded PC 7
1.1 Carton Content..........................................................................................................7
1.2 Verify Jumper Settings..............................................................................................9
1.3 Optional Module Connections.................................................................................11
1.4 Installing Modules....................................................................................................11
1.5 Connecting Peripherals...........................................................................................12
1.6 Verify Operation ......................................................................................................17
2Support, Service & Warranty 19
2.1 How to Contact Us: Technical Support...................................................................19
2.2 Return Material Authorization (RMA) Policies and Conditions................................20
2.3 LIMITED WARRANTY.............................................................................................21
Index 25

PC56 ♦ControlLogix Platform Contents
In-Rack Industrial PC Quick Start Guide
Page 6 of 25 ProSoft Technology, Inc.
November 18, 2009

Installing the PC56 Embedded PC PC56 ♦ControlLogix Platform
Quick Start Guide In-Rack Industrial PC
ProSoft Technology, Inc. Page 7 of 25
November 18, 2009
1 Installing the PC56 Embedded PC
In This Chapter
Carton Content........................................................................................7
Verify Jumper Settings ............................................................................9
Optional Module Connections ...............................................................11
Installing Modules..................................................................................11
Connecting Peripherals.........................................................................12
Verify Operation ....................................................................................17
This Quick Start Guide will help you get your PC56 Embedded PC up and
running. If you need additional information, refer to the appropriate user manual
located on the PC56 CD-ROM shipped with your module.
1.1 Carton Content
Your new PC56 Embedded PC is shipped with the following:
PC56 Embedded PC Two RJ45 to DB-9 Cables

PC56 ♦ControlLogix Platform Installing the PC56 Embedded PC
In-Rack Industrial PC Quick Start Guide
Page 8 of 25 ProSoft Technology, Inc.
November 18, 2009
DB-9 Female to 5 Pos Screw Terminal
Adapter PC56 CD
1.1.1 IDE Modules
If you purchased the PC56-XP-IDE, you will receive a second carton that
contains the IDE module.
1.1.2 Installing Modules
All modules fit into standard slots on the ControlLogix backplane. The PC56
Embedded PC and each IDE or expansion module will each take a slot on the
ControlLogix backplane. For example, if your purchased the PC56-XP-IDE, you
will need two available slots on the backplane. The slots must be side-by-side.
Additional modules take additional slots and all are required to be side-by-side.
To install the PC56 Embedded PC or any of the other modules….
1 Check jumper configurations on each module
2 If required, connect IDE or expansion modules to the PC56 Embedded PC
3 Insert modules in the ControlLogix rack
4 Connect your Peripherals
5 Verify Boot Up

Installing the PC56 Embedded PC PC56 ♦ControlLogix Platform
Quick Start Guide In-Rack Industrial PC
ProSoft Technology, Inc. Page 9 of 25
November 18, 2009
1.2 Verify Jumper Settings
Jumpers are preconfigured, and in most cases, should not be changed. The
following diagrams show the jumper configurations for the PC56 HIST module.
1.2.1 RS-232 (Default)
1.2.2 RS-422 Jumper Setting

PC56 ♦ControlLogix Platform Installing the PC56 Embedded PC
In-Rack Industrial PC Quick Start Guide
Page 10 of 25 ProSoft Technology, Inc.
November 18, 2009
1.2.3 RS-485 Jumper Setting
1.2.4 Jumper Configurations for IDE Drives
IRQ 14
IRQ 15
Otros manuales para InRax PC56
1
Tabla de contenidos
Otros manuales de PC industrial de ProSoft Technology
Manuales populares de PC industrial de otras marcas

Dell
Dell Embedded Box PC 5000 Manual de usuario

IBASE Technology
IBASE Technology ASB200-918 Series Manual de usuario

Lenovo
Lenovo ThinkCentre M90q Manual del propietario

IXXAT
IXXAT Econ 100 Manual de usuario

Kontron
Kontron KBox A-151-TGL Manual de usuario

AXIOMTEK
AXIOMTEK ICO500-518 Series Manual de usuario