Version Date
1.0 June 2016

SAFETY RULES
* Safety can not be assured if instructions are not closely followed.
* The external DC chareger is a Class I equipment, for safety reasons plug it to a
supply line with the corresponding ground terminal.
* Use the mains adapter in Overvoltage Category I and Pollution Degree 1
installations. To use INDOOR.
* When using some of the following accessories use only the specified ones to
ensure safety:
Rechargeable battery.
Mains adapter.
Power cord.
* Observe all specified ratings both of supply and measurement.
* Use this instrument under the specified environmental conditions.
* The user is not allowed to carry out the following maintenance operations:
Any change on the equipment must be carried out exclusively by
technical staff.
* Follow the cleaning instructions described in the Maintenance paragraph.
CAUTION
The battery used can present danger of fire or chemical burn
if it is severely mistreat.
Do not disassembly, cremate or heat the battery above
100 °C under no circumstances.

*Symbols related with safety:
Descriptive Examples of Over-Voltage Categories
Cat I Low voltage installations isolated from the mains.
Cat II Portable domestic installations.
Cat III Fixed domestic installations.
Cat IV Industrial installations.

TABLE OF CONTENTS
1 GENERAL......................................................................................................1
1.1 Description ..............................................................................................1
2 INSTALLATION..............................................................................................2
2.1 Power Supply...........................................................................................2
2.1.1 Operation Using the Mains Adapter ........................................................2
2.1.2 Operation Using the Battery..................................................................2
2.1.3 Battery Charging.................................................................................2
2.1.4 Recommendations using the battery ......................................................3
3 OPERATION INSTRUCTIONS............................................................................4
3.1 Description of Controls and Elements...........................................................4
3.2 Operating Instructions...............................................................................6
3.2.1 Selecting the active Wavelength............................................................6
3.2.2 Signal Modulation................................................................................6
3.2.2 Automatic Sequential Mode Operation....................................................7
4 SPECIFICATIONS...........................................................................................8
5 MAINTENANCE ............................................................................................10
5.1 Instructions for returning by mail..............................................................10
5.2 Maintenance instructions .........................................................................10
5.2.1 Cleaning the cover ............................................................................10
5.3 Components which user can not replace.....................................................10
5.3.1 Not replaceable fuses by user .............................................................10
6 APPENDIX A: OPTICAL ATTENUATION MEASUREMENT IN AUTOMATIC MODE........11
6.1 Description ............................................................................................11
6.2 Measuring the reference power.................................................................11
6.3 Attenuation measurement in the optical network.........................................12

June 2016 1
FTTH TRIPLE LASER SOURCE
PROLITE-105
1 GENERAL
1.1 Description
The PROLITE-105 laser light source emits light at three wavelength that are used
to transmit data through optical fibre on FTTx networks: 1310 for Upstream and
1490 and 1550 nm for Downstream. It allows selecting easily the desired
wavelength by means of direct access keys, in order to generate a modulated
signal or to activate the automatic operation mode.
These light sources may be modulated with 270 Hz, in the case of the wavelength
at 1310 nm, 1 kHz at 1490 nm and 2 kHz at 1550 nm. They are modulated at
different frequencies to measure the attenuation of the fibre for the three
wavelengths in combination with a power meter (such as PROLITE-63 or 67).
Usually this measure is required to certificate telecommunications infrastructures.
The PROLITE series has been designed for starting up and maintaining fibre optic
installations. This series consists of the PROLITE-67 (xPON tester), the
PROLITE-63 (OPM) and the PL330 and PL360 (optical attenuators).

2 June 2016
2 INSTALLATION
2.1 Power Supply
The PROLITE-105 is a portable instrument powered by a rechargeable Li-Ion
battery. The instrument comes with a mains adapter which enables the
PROLITE-105 to be plugged to the mains for operation and battery charging.
2.1.1 Operation Using the Mains Adapter
Connect the mains adapter to the PROLITE-105 through the external power
connector [7] placed at the right side of the instrument. Then, connect the adapter
to the mains to start up battery charging. Next, press the ON/OFF [3] key.
Then the instrument starts working.
CAUTION
Before using the mains adapter make sure that it is the appropriate one
for your mains voltage.
The mains adapter is designed for indoor use.
2.1.2 Operation Using the Battery
Press the key ON/OFF [3]. to start the instrument powered by the battery.
When the battery is full loaded, the PROLITE-105 has an autonomy aprox. of 25
hours of continuous work in SEQ mode.
When the battery is flat, the instrument will not start up or, if working, will switch
off. The LOW BATT indicator [1] will be lit whenever the battery charge is low.
Then a charge process is required.
2.1.3 Battery Charging
First switch off the PROLITE-105 in order to charge the battery. Then connect the
power input to the mains adapter. Now connect the adapter to the mains. Now you
can observe that the indicator CHARGE CHG [6] is lit in amber which indicates the
battery is charging. Charging time depends on the state of the battery. If the
battery is flat, the battery charging time is 3 hours aprox. When battery is full
loaded, the charge indicator CHG [6] changes to green.

June 2016 3
2.1.4 Recommendations using the battery
If anticipating a long period of inactivity for your instrument, it is advisable to
store it with the battery fully charged and at temperatures below 25 ºC.
It is also advisable in these cases to carry out a cycle of charging/discharging and
a subsequent half charge (i.e. 50 %) every 3 months.

4 June 2016
3 OPERATION INSTRUCTIONS
3.1 Description of Controls and Elements
Front Pannel
Figure 1.- Front View of the PROLITE-105.
BATTERY STATUS.
It indicates the status of the battery charge.
When it is illuminated, it indicates that the battery level is low and it is
going to switch off.
POWER LED.
When it is ON indicates that the unit is working.
ON / OFF.
It turns ON or OFF the unit.
LASER LIGHT SOURCES
It activates in an individual way a source of light of 1310 nm, 1490 nm or
1550 nm. There is a button to activate each one.
At first press on one of these buttons it turns on the corresponding source
of continuous light. LED is GREEN.
At second press again on the same button it switches to the same source
of light but modulated. LED is AMBER.
At every press it switches between continuous and modulated light.
When pressing for more than one second it turns off the light and the LED.
These three light sources can work simultaneously.

June 2016 5
SEQUENCING.
Button with three states:
First press: All laser sources without modulation are activated.
Second press: All laser sources are activated sequentially in
modulated mode.
Third press: It disables all laser sources.
CHARGE LED
It indicates the state of the battery charge.
When the LED is in AMBER means that is charging.
When the LED is in GREEN means that is in full charge and it is being
powered through the means.
Side view
Figure 2.- Side view PROLITE-105.
Connector SC / APC Fibre signal output or active signals.
Anchor Point conveyor belt.
External power input of 12 V.
Tabla de contenidos
Manuales populares de Equipo de iluminación de otras marcas

Qazqa
Qazqa Suplux SL 3 Black 103062 Manual de usuario

Commercial Electric
Commercial Electric 54568141 Manual de usuario

CREE LIGHTING
CREE LIGHTING 304 Series Manual de usuario

Goobay
Goobay 49867 Manual de usuario

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Manual de usuario

Alkalite
Alkalite Krypton KT-81 Manual de usuario