http://prolux.net.ua
2
manual carefully before installing the device.
Attention
To keep your machine in good working order please remember to:
●Use only water-based, non-toxic haze liquid.
●Keep the machine clean.
●Turn the power off before adding liquid.
●Turn the power off when not in use.
Also...
●Always make sure that you are connecting to the proper voltage , and that the line voltage you are
connecting to is not higher than that stated on the decal or rear panel of the fixture.
●This product is intended for indoor use only.
●To prevent risk of fire or shock , do not expose this unit to rain or moisture.
●Make sure there are not flammable material close to the unit while operating.
●The unit must be installed in a location with adequate ventilation, at least 20in (50cm) from adjacent
surfaces. Be sure that no ventilation slots re blocked.
●Always disconnect from the power source before servicing or replacing fuse and be sure to replace
with same fuse size and type.
●In the event of a serious operating problem. Stop using the unit immediately. Never try to repair the
unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center. Always use the same type spare parts.
●Never connect the device to a dimmer pack.
●Make sure the power cord is never crimped or damaged.
●Never disconnect the power cord by pulling or tugging on the cord.
VOLUME : when the haze ready to emit , press the button VOLUME, the haze will emit continuously.
Press again ,it stops working.
Manual : press the button MANUAL , the haze will emit, hold pressing and the haze will emit
continuously. Release it stop working.
Routine Maintenance and common faults
Periodically clean your machine to reduce replacement parts and repair expenses.
1. The poor fog liquid can cause blockage, it is recommended to use high quality fog liquid.
2. The machine might be blocked due to high concentration fluid, not clean fluid or overheat, so regular
care and maintenance can ensure long-term use. After about 40 hours continually use, please use 80%
distilled water and 20% white vinegar to remove the accumulated impurities inside the heat pipe , as
following:
1)washing the pipe in the tank and the filter head.
2)Pour out the fog liquid , replacing the cleaning liquid ( 80% distilled water and 20% white vinegar),
turn on the power , keep it operating till the cleaning liquid runs out.
3. If the fog turns less, and the pump makes noise, or can not spray fog, you should turn off the power
immediately and at the same time check the fluid tank, fuse and power plug. If all of these are normal,
please connect the power with the plug and try again, if the problems still can not be solved, you should
contact supplier.
Note : Before replacing a fuse , disconnect power cord. Always replace with the same type and rating of
fuse.
Connecting A bunch of machines