Grill fixings
To wall
Leg bracket fixing centres
500
240
Secure trough stand
base to grill base
Tec nical Installation Information Table
Note
* 13A Fuse Rating: The unit must be protected by
a 13 amp fuse if a 13 amp plug is used. If another type
of plug is used, a 15A fuse requires to be used in the
plug, adaptor or distribution board.
Dimensions
- 600mm (W) x 350mm (D) x 285mm (H)
Vertical Clearance
- 900mm
Side & Rear Clearance
- 150mm
Weig t
- 18.5kg
Power Rating
- 2.65kW
Fuse
- 13 amp
SECTION 1 - SITING
PRO-LITE models have been designed in a modular
form which consists of base, counter and free-standing
units.
Information which relates to individual models is listed
above.
Free-standing and base models should be installed
upon a firm, level surface and adjustable feet are
provided for levelling purposes.
ounter units must be positioned upon a table, counter
or similar surface.
Vertical and horizontal clearances required from the top
and sides of a particular unit to any overlying
combustible surface (ie wall, partition, etc) are listed
above. Relevant fire regulations must be complied with.
Grill Mounting
The grill can be mounted directly upon a table, counter
or similar surface and must be secured accordingly.
It may also be secured upon a leg stand which requires
to be fixed to the surface using the brackets supplied.
WARNING: Never mount a grill directly upon a
combustible surface wit out a leg stand.
The stand assembly is supplied as an optional extra and
secured to the unit base with the fixings provided
(see Figure 1).
Figure 1a
Figure 1b
Figure 2
The leg locating brackets then require to be secured to
the worktop surface using the appropriate fixings.
ThefixingcentresareindicatedinFigure1b.
The brackets should then be rotated to ensure that
the location holes correspond with the side fixing hole in
each leg. Locate the brackets up inside the legs and
insert one fixing in each to secure the assembly.
A further option is to position the grill upon an optional
shelf bracket (see Figure 2). The installer should ensure
that the wall upon which the shelf is to be mounted can
support the weight. This requires to be plugged to
accomodate No.8 wood screws or equvalent of at least
50mm in length.
To fix, hold the shelf horizontally in the desired position
and mark the fixing holes through the flanges prior to
drilling. Insert the plugs and secure the bracket firmly in
position. The grill should then be placed upon the
bracket and located using the fixings provided.
Either option requires an installation clearance of 50mm
at the sides and rear to be observed.
SECTION 2 -
ELECTRICAL SUPPLY AND CONNECTION
Electrical ratings are as stated on t e unit data
plate. T e listing in Table 1 is based on standard UK
specification at 230V
~
. Wiring must be executed in
accordance wit t e regulations listed in t is
booklet.
WARNING: Eac individual appliance must be
eart ed!
After completion of installation, the method of operation
should be demonstrated to the kitchen staff.
The isolating switch location, for use in an emergency
or during cleaning should also be pointed out.
This model is designed to be connected to a single
phase A supply using the 2 metre mains lead fitted as
standard.
Wires are coloured in accordance with the following
code and should be connected to the plug as follows:
EARTH to terminal marked E or coloured GREEN or
GREEN/YELLOW.
NEUTRAL to terminal marked N or coloured BLA K.
LIVE to terminal marked L or coloured RED.
Units which receive power from a plug, adaptor or
distribution board must be individually protected by a
fuse with an appropriate rating.
Any replacement supply cable must be 1.5mm
2
,
cord code designation 245 IE 57 ( ENELE
H05 RN-F).
For internal connection, outer sheathing must be
stripped 140mm from the cable end. The live and
neutral conductors must be trimmed so that the Earth
conductor is longer by 50mm. Pass inlet cable through
the rear panel cord grip and ensure that the cable is
routed without leaving excessive free length inside the
appliance.