Procentec ProfiHub A5 Manual de usuario

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 1 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
User Manual
ProfiHub A5/B5
5 Channel DP Spur and Repeater component
5 Isolated Channels.
Transparent for all PROFIBUS DP protocols.
RS 485 specifications for each channel.
Max. 12 Mbps.
Max. 31 devices per channel.
Max. 1200 m spur line length.
No limit in serial placement.
No address required.
Integrated termination facilities.
Configurable grounding system.
IP 65 classification (ProfiHub A5).
IP 20 classification (ProfiHub B5).

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 2 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
Safety Guidelines
This manual contains notices which you should observe to ensure your own personal safety, as well
as to protect the product and connected equipment. These notices are highlighted in the manual by a
warning sign and are marked as follows according to the level of danger:
Draws your attention to important information on handling the product, a particular part of the
documentation or the correct functioning of the product.
Warning
This device and its components may only be used for the applications described in this manual and
only in connection with devices or components that comply with PROFIBUS and an RS 485 interface.
This product can only function correctly and safely if it is transported, stored, set up, installed,
operated and maintained as recommended.
Qualified Technicians
Only qualified technicians should be allowed to install and work with this equipment. Qualified
technicians are defined as persons who are authorized to commission, to ground, to tag circuits and
systems in accordance with established safety practices and standards. It is recommended that the
technicians carry a Certified PROFIBUS Installer or Certified PROFIBUS Engineer certificate.
Disclaimer of Liability
We have checked the contents of this manual as much as possible. Since deviations cannot be
precluded entirely, we cannot guarantee full agreement. However, the content in this manual is
reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for
improvement are welcomed.
Copyright © 2005-2014 PROCENTEC
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or
otherwise, without the prior written permission of the publisher.
PROCENTEC
Klopperman 16
2292 JD WATERINGEN
The Netherlands
Tel.: +31-(0)174-671800
Fax: +31-(0)174-671801
Email: info@procentec.com
Web: www.procentec.com

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 3 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
Important Information
Purpose of the Manual
This manual explains how to put the ProfiHub A5 and ProfiHub B5 into operation.
Recycling and Disposal
The parts of the ProfiHub can be recycled. For further information about environment-friendly recycling
and the procedure for disposing your old equipment, please contact:
PROCENTEC
Klopperman 16
2292 JD WATERINGEN
The Netherlands
Tel.: +31-(0)174-671800
Fax: +31-(0)174-671801
Email: info@procentec.com
Document Updates
You can obtain constantly updated information on PROCENTEC products on the Internet at
www.procentec.com
You can also contact PROCENTEC Customer Support:
- by phone at +31-(0)174-671800
- by fax at +31-(0)174-671801

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 4 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
Contents
1Product Description...................................................................................................................... 5
1.1 Product Features.................................................................................................................... 6
1.2 Application areas.................................................................................................................... 7
1.3 Additional Benefits ................................................................................................................. 7
1.4 Channel Structure .................................................................................................................. 8
1.5 Grounding System ................................................................................................................. 8
1.6 Cable lengths for PROFIBUS DP........................................................................................... 9
1.7 Cable types for PROFIBUS DP............................................................................................ 10
1.8 Status Display ...................................................................................................................... 11
1.9 Comparison table................................................................................................................. 12
2Installation Instructions ProfiHub A5 ....................................................................................... 26
2.1 Location................................................................................................................................ 26
2.2 Position................................................................................................................................. 26
2.3 Mounting............................................................................................................................... 26
2.4 Power Supply....................................................................................................................... 27
2.5 Backbone ............................................................................................................................. 28
2.6 Spur Segments..................................................................................................................... 29
2.7 Termination .......................................................................................................................... 30
2.8 Baudrate switch.................................................................................................................... 31
3Installation Instructions ProfiHub B5 ....................................................................................... 32
3.1 Location................................................................................................................................ 32
3.2 Position................................................................................................................................. 32
3.3 Mounting............................................................................................................................... 32
3.4 Power Supply....................................................................................................................... 32
3.5 Backbone ............................................................................................................................. 33
3.6 Spur Segments..................................................................................................................... 34
3.7 Termination .......................................................................................................................... 35
3.8 Baudrate switch.................................................................................................................... 36
4Technical Data ProfiHub A5....................................................................................................... 37
5Technical Data ProfiHub B5....................................................................................................... 39
6Sales offices and Distributors................................................................................................... 41
7Order codes................................................................................................................................. 41
8Glossary....................................................................................................................................... 47
9Certificates .................................................................................................................................. 50
10 Revision History.......................................................................................................................... 53
11 Next version ................................................................................................................................ 54
12 Notes............................................................................................................................................ 55

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 5 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
1 Product Description
ProfiHub A5 and B5 are advanced, flexible
and robust network components for
PROFIBUS DP installations, to implement
long multi-device spur lines and backbone
structures with star/tree segments.
PROFIBUS DP is a high speed communication
bus that has to comply with strict rules
concerning spur lines, because of possible
reflections that could lead to communication
disturbances. If spur lines or star segments are
required, costly investments in repeaters have
to be done.
Innovative components for such applications are
the ProfiHub A5 and B5. These are perfect
economic solutions to implement reliable spur
lines in high speed DP networks. They have the
functionality of 5 galvanic isolated transparent
repeaters. This allows network structures with
extended spur lines that individually can handle a
maximum of 31 devices and a length equal to the
main bus. The ProfiHub A5 and B5 refresh a
received message on one Channel and
transfer it to all the other Channels (chicken
foot topology).
Because the ProfiHub A5 and B5 create isolated
segments, the devices can now be removed and
added during operation. Also electrical bus
problems and EMC disturbances in a spur do not
spread to the other segments. The intelligent
logic and isolation circuits of the ProfiHubs do not
change the bit width. This means the ProfiHubs
do not have limitations in serial placement. The
logic also detects the transmission speed
automatically.
To assist the installation work, termination is
integrated and can be switched on/off. The
grounding concept is also selectable: direct or
capacitive grounding. The ProfiHubs are powered by a 10 to 32 DC Voltage (110/230V AC versions
are also available). For troubleshooting, maintenance and commissioning the ProfiHubs are equipped
with a display on the outside, which indicate the status of each Channel (Data and Error).
Fig. 1 - ProfiHub A5 (IP65)
i
Fig. 2 - ProfiHub B5 (IP20)

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 6 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
1.1 Product Features
5 Galvanic isolated channels (repeater
segments).
Transparent for all PROFIBUS DP
protocols.
DP - RS 485 specifications for each
channel.
9,6 Kbps to 12 Mbps.
31 devices per channel.
1200 m spur line length (depends on
transmission speed).
No limit in serial placement or cascading of
ProfiHubs.
No address required.
Integrated termination facilities (switches).
Configurable grounding system (direct or capacitive).
IP 65 classification (ProfiHub A5).
IP 20 classification (ProfiHub B5).
Fig. 3 - Long spur lines to instruments and the possibility to remove/insert them during
operation. Short circuit protection on each spur line is automatically provided.

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 7 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
1.2 Application areas
Dynamic spur lines to actuators, flow meters and pH analyzers.
Removable drives and motors.
Pull/Plug motor control centers (drawers).
Roof mounted devices in tank farms.
Dirty and humid environments.
Barrier for non galvanic isolated equipment.
Large star/tree structured networks.
Outdoor applications with device and cable stress (ProfiHub A5).
1.3 Additional Benefits
Hot slave insertion and removal during operation.
Short circuit protection on each Channel.
Compact and robust construction.
Status and error display (per Channel).
Suitable for all DP cables.
Conveniently arranged networks.
Easy extendable installations.
Standard glands can be replaced with M12 (ProfiHub A5).
On-board DB9 female connector for maintenance activities (ProfiHub A5).
Cost Savings.
Fig. 4 - Because of the isolation and intelligence the ProfiHub provides, it can be used as
a barrier for electrically sensitive segments. This keeps the backbone and other
Channels clean.

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 8 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
1.4 Channel Structure
Every Channel is electrically isolated and internally connected to the transparent intelligent backbone.
The termination is switchable and powered by the ProfiHub. The shielding of the PROFIBUS cable can
be directly grounded or indirectly grounded (see the next paragraph).
1.5 Grounding System
The ProfiHubs can be grounded by 3 methods:
1) Direct grounding
2) Indirect grounding (through a capacitor)
3) Combination of direct and indirect.
In most cases it is recommended always to use Direct Grounding with the power supply and the
shielding of the PROFIBUS cables. If you do not want to ground all or some cables to the common
ground, the cable shielding should be connected to pin ‘I’. A capacitor with a parallel high value
resistor will separate the 2 potentials (Fig. 5).
If by accident on 1 channel the Direct Grounding is connected with the Indirect Grounding, the Direct
Grounding “wins”.
Fig. 5 - Channel structure

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 9 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
1.6 Cable lengths for PROFIBUS DP
The cables on the Channels and the Main-Channel should comply with the PROFIBUS DP cable
specifications for RS 485 (Fig. 6).
Fig. 6 - Cable lengths for PROFIBUS DP

ProfiHub A5/B5 User Manual
_______________________________________________
Version 2.1.1 –June 2014 Page 10 / 59
ProfiHub-A5B5-Manual-EN © PROCENTEC 2005-2014 - Copyright - all rights reserved
1.7 Cable types for PROFIBUS DP
The cable type should comply with the PROFIBUS DP cable specifications for RS 485 (Fig. 7).
The ProfiHub A5 can handle cables based on multiple protection sheaths with a diameter between 6 to
12 mm (Fig. 8).
Parameter
Value
Wires
2 (twisted)
Impedance
135 .. 165 Ohm at 3 to 20 MHz
Capacity
< 30 pF/m
Loop resistance
< 110 Ohm/km
Wire diameter
> 0.64 mm
Wire area
> 0.32 mm2
FRNC cable
Shipboard cable
Festoon cable
Flexible cable
Food cable
Robust cable
Trailing cable
Hybrid cable
Fig. 8 - Cables with different protection sheaths.
Fig. 7 - PROFIBUS DP cable specifications
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Manuales populares de Accesorios de red de otras marcas

Patton electronics
Patton electronics 2888 Manual de usuario

Cradlepoint
Cradlepoint COR IBR1100/IBR1150 Manual de usuario

Paradyne
Paradyne Hotwire 8620 Manual de usuario

Infra Cool
Infra Cool F-1.3 Manual de usuario

Edgewater Networks
Edgewater Networks 4300T Manual de usuario

Edimax
Edimax SB-2200g Manual de usuario

Extreme Networks
Extreme Networks Mogul-100 Manual de usuario

Aaeon
Aaeon FWS-8500 Manual de usuario

Panduit
Panduit Z11C Series Manual de usuario

F5
F5 BIG-IP 10000 Series Instrucciones de montaje

ZyXEL Communications
ZyXEL Communications NMA1115 Manual de usuario

Auerswald
Auerswald COMtrexx Business Manual de usuario