Pro-tec AC-200-dual Manual de usuario

PROTEC AC-200-dual USER MANUAL
AC-200-dual
USER MANUAL

PROTEC AC-200-dual USER MANUAL
Congratulations on the purchase of the AC-200-dual
Refrigerant Processor
This is a very good investment you have made for your workshop. This system will help your technicians in achieving their
best capability in diagnosing and rectifying air-conditioning issues, thus increasing productivity and profitability for your
business. This system can be customized to suit each individual workshop needs. Our company would like to work with you
as partners in your business to help you achieve maximum return on your investment, so please do not hesitate to contact us
or our distributors, if we can be of any further assistance in relation to this equipment use and maintenance, or any
air-conditioning related issues. We are always here to help you in achieving higher productivity.
AC-200-dual is an ideal option for workshops that have requirements of handling both R-134a and HFO-1234yf refrigerants.
The loss of refrigerant is minimized to less than 50 gram at shifting from one refrigerant to another, and deep internal
evacuation ensures zero cross contamination between two refrigerants. The machine is equipped with 2 refrigerant tanks,
which saves the operators' time of replacing tanks.
The unique design has facilitated quick load cell unlock, easy and economic maintenance (even though DIY maintenance is
facilitated by our machine design, it is still highly recommended to leave maintenance job to specialized technicians.), self
troubleshooting and convenient USB upgrade etc..
General safety
The storage cylinder in this unit contains liquid refrigerant. Overfilling of the cylinder can cause violent explosion. Do
not disable the overfill safety feature. Always keep the cylinder on the load cell platform whenever operating the
machine.
The operator must carefully read the instruction manual before any operation is performed. Incorrect operations could
cause serious consequences, such as, improper A/C service, damage to automotive A/C system or damage to
equipment.
Only use cylinders which are recommended by the manufacturer and supplied with this equipment.
Avoid inhalation of refrigerant or oil vapor/mist, read material safety instructions on refrigerant and oil package.
Switch off and disconnect power cable from main supply before removing any cover or servicing the equipment, to
avoid electric shock which can be very dangerous or fatal.
Never use compressed air for leak testing the unit or vehicle A/C system!
Wear safety goggles and gloves, to protect eyes and skin from contact with refrigerant. Coming in contact with liquid
refrigerant can cause frostbite and blindness. If accidental contact is made with liquid refrigerant, wash effected area
with plenty of fresh water and contact a doctor.
Avoid using extension power cable with copper core diameter less than 1.5mm2.
Keep gasoline or other flammable substances away from the equipment.
Always operate unit in a well-ventilated area and away from artificial heat

TEKTINO AC-200-dual USER MANUAL V2.30
1/14
Index
SPECIFICATIONS----------------------------------------------------------------------------------------------------------------2
FUNCTION TABLE--------------------------------------------------------------------------------------------------------------3
PART DESCRIPTION------------------------------------------------------------------------------------------------------------4
OPERATION PREPARATIONS-------------------------------------------------------------------------------------------------5
EQUIPMENT CONNECTION(Recovery/vacuum/oil injection/charge/Tank fill/auto mode)--------------------------7
RECOVERY------------------------------------------------------------------------------------------------------------------------8
VACUUM---------------------------------------------------------------------------------------------------------------------------8
OIL INJECTION-------------------------------------------------------------------------------------------------------------------9
CHARGE---------------------------------------------------------------------------------------------------------------------------9
TANK FILL-------------------------------------------------------------------------------------------------------------------------9
AUTO. MODE--------------------------------------------------------------------------------------------------------------------10
SYSTEM SETTING-------------------------------------------------------------------------------------------------------------10
UPDATE---------------------------------------------------------------------------------------------------------------------------11
SERVICE REMINDING--------------------------------------------------------------------------------------------------------12
MAIN TROUBLESHOOTING------------------------------------------------------------------------------------------------13

TEKTINO AC-200-dual USER MANUAL V2.30
2/14
Specifications:
Dimension:Package 710*660*1190mm; Unpacked machine 610*595*1075mm3
Input power:AC220V±10%~50/60Hz,or AC110V±10%~60Hz
Pre-ventilation: the machine makes 30 seconds ventilation, before it is powered on.
Compressor power:3/8HP
Average gas state refrigerant recovery speed (through charge/suction port):0.25Kg/min.
Hand valves free.
Recovery rate: 96%.
Vacuum pump capacity:120L/min, non-sparkle.
Accuracy of gas cylinder load cell:±10g
Capacity of dual gas cylinders (one for R-134a, one for HFO-1234yf):10KG
New oil bottle capacity:250ml
Used oil bottle capacity: 400ml
Dual condensers and cooling fans, one for R-134a, one for HFO-1234yf
Max. Pressure:20bar
Charge speed:2Kg/Min(max.)
LCD display:4.3-inch,TFT full color
High pressure gauge range:-1bar~40bar
Low pressure gauge range:-1bar~22bar
A/C database included, update through USB port.
Automatic service reminding. The equipment provides 600 operations totally (each recovery or vacuum
counts for one operation, and automatic mode counts for 2 operations) between regular maintenance, When
600 operations have been made the machine automatically reminds to call distributor for service.

TEKTINO AC-200-dual USER MANUAL V2.30
3/14
Function Table
Main function
Recovery
Recovers and purifies refrigerant from automotive A/C
to equipment tank.
Vacuum
Evacuates air and moisture from the A/C system.
Oil injection
Inject refrigeration oil to automotive A/C system.
Can inject oil by setting volume manually, or
automatically.
Charge
Charge refrigerant from equipment gas cylinder to
automotive A/C system
Tank fill
Transfer liquid refrigerant from an external refrigerant
storage cylinder to equipment cylinder.
Auto. mode
Performs the selected functions in a fully automatic
sequence. The machine will stop automatically once all
the selected functions have been completed
Sys. setting
Language
Select operation language.
Calibration
Calibration refrigerant gas cylinder load cells.
Database
Enter automotive A/C database
Unit set
Select metric or imperial units
Empty container weight set
Set empty refrigerant gas cylinder.
Component test
Test work status of solenoids, vacuum pump and
compressor.

TEKTINO AC-200-dual USER MANUAL V2.30
4/14
Equipment description
Front view
Back view
Left view
Right view
Key pad
LP gauge
R134a/HFO1234yf
Coupler connect
fittings
LCD screen
HP gauge
Fuse
Power
switch
Vacuum pump
New oil
vessel
Used oil
vessel
R134a
refrigerant tank
HFO1234yf
Refrigerant tank
R134a tank
gauge
Non-condensable
purge valve for
R134a tank
HFO1234yf
tank gauge
Non-condensable
purge valve for
HFO1234yf tank

TEKTINO AC-200-dual USER MANUAL V2.30
5/14
OPERATION PREPARATIONS
Unlock load cells.
Remove the two lock bolts, to release load cells of the two tanks, and to make them ready to work.
Warning:
1. Failure to remove the load cell lock bolts may cause wrong refrigerant processing amount.
2. When you need transport the machine, please screw those bolts on.
Fill equipment with refrigerant (New equipment is empty, you need to fill the equipment
with refrigerant and refrigeration oil)
Through tank fittings, connect either HP or LP hose with external refrigerant R134a or
HFO-1234yf, and turn on the machine, select “Tank fill” function, set tank fill amount to fill
R134a or HFO-1234yf tank with refrigerant.
It is recommended to maintain refrigerant level of both tanks at 4-6kg.

TEKTINO AC-200-dual USER MANUAL V2.30
6/14
Non-condensable purge
It is recommended to purge the air in equipment tanks every day before turning on the machine.
At left and right sides of machine, non-condensable purge manual valves and
pressure-temperature chart can be found. Turn the valve to purge the non-condensables, strictly
abiding by the pressure-temperature chart sticker.
Select refrigerant
Each time the machine is turned on, it reminds to select refrigerant type. If the refrigerant type
selected is different from the refrigerant handled at previous operation, the machine automatically
recovers refrigerant inside machine pipelines, and makes extremely deep internal evacuation, and
then shifts to the interface of the selected refrigerant. This process may take 5 minutes or more.
Notes:
1. Be sure you select same refrigerant type as what the vehicle contains, or serious
contamination in equipment tanks will be caused.
2. Anytime you desire to shift from the refrigerant which machine currently handles to
another, turn the machine off and turn it on again, and then select refrigerant type.

TEKTINO AC-200-dual USER MANUAL V2.30
7/14
Equipment Connection (For recovery/vacuum/oil injection/charge/Auto. Mode)
Warning: Except the situations clearly stated in the manual, during all equipment operations, please maintain
the vehicle engine and A/C off, otherwise unexpected damages may be caused.

TEKTINO AC-200-dual USER MANUAL V2.30
8/14
Recovery
Empty used oil vessel before the recovery function is started.
Select “Recovery” function icon and press ENTER to start the process.
The recovery process recovers the refrigerant from vehicle A/C system, until vacuum degree is
achieved in the vehicle A/C system. Moisture, oil and foreign particles are separated from the
refrigerant before it is stored in the internal refrigerant cylinder. The machine should be left
connected on the vehicle for a minimum time of 3 minutes (longer in cold climates) for any
pressure increase test. If after 3 minutes (or longer if possible) there is no pressure increase, the
recovery can be acknowledged completed. If a pressure increase is detected recovery should be
processed again.
Vacuum
Select “Vacuum” icon and press ENTER to start the process.
The Vacuum process evacuates system, and makes system ready for oil injection and refrigerant
charge. Although it is up to users to determine vacuum time, a longer vacuum process is
recommended.
Tabla de contenidos